Skip Navigation

European Heart Journal 1980 1(1):45-54;
Copyright © 1980 by the European Society of Cardiology.
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by SUTHERLAND, G. R.
Right arrow Articles by HUNTER, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by SUTHERLAND, G. R.
Right arrow Articles by HUNTER, S.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© 1980 The European Society of Cardiology

Sub-xiphoid echocardiography—a new approach to the diagnosis and differentiation of atrioventricular defects

G. R. SUTHERLAND, G. J. VAN MILL, R. H. ANDERSON and S. HUNTER

Freeman Hospital, Newcastle upon Tyne, Wilhelmina Kinder-Ziekenhuis Utrecht and Brompton Hospital, London

Received 7 December 1979; .

M-Mode echocardiography provides a non-invasive technique with which to analyse atrioventricular valve status and atrioventricular junction anatomy. The parasternal approach is limited in this respect as it does not profile the inlet ventricular septum. Examination of autopsy specimens suggested that the sub-xiphoid approach should selectively profile the inlet septum and its relationships to the atrioventricular valves. We have developed a composite M-Mode sub-xiphoid scan and assessed its value in the analysis of the atrioventricular junction in 107 children with normal hearts and 71 children with documented atrioventricular defects (34 partial, 37 complete). The latter group was studied both by parasternal and sub-xiphoid approaches to compare the relative values of the two methods in differentiating complete from partial defects.

The parasternal approach failed to identify the correct atrioventricular junction anatomy in 15 cases. In contrast, sub-xiphoid M-Mode scanning predicted the correct atrioventricular junction anatomy in all 71 cases, allowing visualization of the common atrioventricular valve and inlet ventricular septal defect where these were present.

It is concluded that the sub-xiphoid approach is the M-Mode echocardiographic technique of choice in differentiating between partial and complete forms of atrioventricular defects offering an increase in diagnostic accuracy over both left-ventricular cine-angiography and parasternal M-Mode echocardiographic scanning.

Key Words: Atrioventricular defect • M-Mode echocardiography • sub-xiphoid


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer:
Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.