Skip Navigation

European Heart Journal 1989 10(7):602-610;
Copyright © 1989 by the European Society of Cardiology.
This Article
Right arrow Full Text (PDF)
Right arrow E-letters: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by HAISSAGUERRE, M.
Right arrow Articles by WARIN, J. F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by HAISSAGUERRE, M.
Right arrow Articles by WARIN, J. F.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© 1989 The European Society of Cardiology

Closed-chest ablation of left lateral atrioventricular accessory pathways

M. HAISSAGUERRE and J. F. WARIN

Service de Cardiologie et Médecine Interne, Hôpital Saint-André Bordeaux, France

Received 13 June 1988; revised 5 January 1989; .

Requests for reprints: M. Haissaguerre, Service de Cardiologie et Medecine Interne, Hôpital Saint-Andre, Bordeaux, France

Abstract

Thirty patients with a left lateral accessory pathway and drug refractory tachycardia underwent attempted transcatheter ablation of the accessory pathway. Three had a concealed accessory pathway and 27 had the Wolff-Parkinson-White syndrome. A quadripolar electrode catheter was positioned within the coronary sinus in order to locate the earliest retrograde atrial activation during orthodromic reciprocating tachycardia. The appropriate bipole was used as the radiographic and electrophysiologic reference of the insertion of the accessory pathway. A catheter was then introduced into the left atrium, through a patent foramen ovale (six patients) or after transseptal catheterization (14 patients) according to Croft's technique, or using a retrograde transaortic approach (10 patients).

The mitral annulus was mapped with the left atrial catheter in order to record a synchronous or earlier atrial deflection than reference during reciprocating tachycardia. VA' time at the preablation site was 82 ± 12 ms. Two to seven 160 J cathodal shocks (650 ± 205 J cumulative per patient) were delivered at this site in 38 sessions. No significant side-effects occurred except for one case of right coronary artery spasm leading to inferior wall infarction.

Following fulguration, accessory pathway conduction was abolished in all patients but one with a second accessory pathway. During follow-up of 1–34 months, all patients but one were free of tachycardia: reciprocating tachycardia recurred in one patient, who had a concealed accessory pathway, on the third day. Accessory pathway conduction, assessed in 10 other patients 3–26 months after the procedure, was absent. Coronary arteriography performed in seven patients was normal.

Catheter ablation of left free-wall accessory pathways is both safe and effective with shocks directly delivered to the mitral annulus through a transseptal or transaortic catheter. It is an attractive alternative to surgical ablation of these accessory pathways.

Key Words: Accessory pathway • catheter ablation


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
EuropaceHome page
Y. Hosaka, M. Chinushi, K. Takahashi, K. Ozaki, T. Yanagawa, T. Miida, H. Oda, and Y. Aizawa
Coronary vasospasm triggered ventricular fibrillation delayed after radiofrequency ablation of the right accessory pathway
Europace, November 1, 2009; 11(11): 1554 - 1556.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.