Skip Navigation

European Heart Journal 1989 10(7):637-646;
Copyright © 1989 by the European Society of Cardiology.
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by RITTER, P.
Right arrow Articles by GOUFFAULT, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by RITTER, P.
Right arrow Articles by GOUFFAULT, J.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© 1989 The European Society of Cardiology

Haemodynamic benefit of a rate-adapted A-V delay in dual chamber pacing

P. RITTER, C. DAUBERT, P. MABO, C. DESCAVES and J. GOUFFAULT

Department of Cardiology, University Hospital of Rennes France

Received 23 May 1988; revised 6 December 1989; .

Address for reprints: Dr Ph. Ritter M.D., CHR de Rennes, Hotel Dieu, 35033 Rennes Cedex, France

Abstract

In dual chamber pacing, an improvement of exercise capacity is expected when the atrial refractory period is shortened, because the 2/1 point is increased. This objective can be achieved by greatly reducing atrio-ventricular delay (AVD) on exercise. Are such variations (up to 100–120 ms) detrimental from a haemodynamic standpoint? This study was performed to analyse this particular aspect of DDD pacing. Three DDD pacing modes, differing by their AVDs (fixed 200 ms AVD, fixed 150 ms AVD, and rate-adapted AVD) were tested in random order, with a haemodynamic protocol including ten patients with chronic atrio-ventricular (A-V) block. For the rate-adapted AVD pacing mode, AVD was reduced by 20 ms every 10beats min–1 increment (from 220 ms at 90 beats min–1 to 100 ms at 150 beats min–1). Pacing rate was increased from 90 to 150 beats min–1 by increments of 10 beats min–1 every 5 min.

Cardiac performance was significantly improved with the rate-adapted AVD above the two fixed AVDs, despite a large A VD variation. When A VD was rate adapted, cardiac index, stroke volume index and left ventricular systolic work index were generally higher and pulmonary capillary wedge pressure, pulmonary arterial pressure and systemic vascular resistances were generally lower, especially at 120, 130 and 140 beats min–1. Comparing the two fixed AVDs, 200 AVD improved cardiac function more at lower heart rates, whereas 150 AVD improved cardiac function more at higher heart rates. Despite its limitations, this study demonstrates that the potential benefits of reducing AVD with increasing heart rates should be twofold in dual chamber pacing:

  1. haemodynamic, optimizing cardiac performance on exercise for all heart rates, especially in cases of organic heart disease;
  2. electrophysiologic, permitting a sufficiently rapid maximal tracking rate in cases with long post-ventricular atrial refractory periods, allowing a satisfactory level of exercise.

Key Words: Dual chamber pacing • atrio-ventricular delay • haemodynamics


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
CirculationHome page
M. H. Schoenfeld
Contemporary Pacemaker and Defibrillator Device Therapy: Challenges Confronting the General Cardiologist
Circulation, February 6, 2007; 115(5): 638 - 653.
[Full Text] [PDF]


Home page
ChestHome page
C. R. Tomczak, W. Wojcik, E. F.G. Busse, and R. G. Haennel
Phase I and Phase II Oxygen Uptake Kinetics During Atrioventricular Dyssynchrony in Chronotropically Competent Pacemaker Patients
Chest, September 1, 2005; 128(3): 1782 - 1789.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
J.C. Nielsen, A.K. Pedersen, P.T. Mortensen, and H.R. Andersen
Programming a fixed long atrioventricular delay is not effective in preventing ventricular pacing in patients with sick sinus syndrome
Europace, January 1, 1999; 1(2): 113 - 120.
[Abstract] [PDF]



Disclaimer:
Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.