Skip Navigation

European Heart Journal 1990 11(2):98-107;
Copyright © 1990 by the European Society of Cardiology.
This Article
Right arrow Full Text (PDF)
Right arrow A correction has been published
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by BERNARD, Y.
Right arrow Articles by MAURAT, J. P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by BERNARD, Y.
Right arrow Articles by MAURAT, J. P.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© 1990 The European Society of Cardiology

Aortie valve area evolution after percutaneous aortic valvuloplasty

A prospective trial using a combined Doppler echocariographic and haemodynamic method

Y. BERNARD, J. P. BASSAND, T. AUGUENOT, F. SCHIELE, S. ABDIY, P. JACOULET, F. GUGEL and J. P. MAURAT

Department of Cardiology, University Hospital Besancon, France

Received 5 January 1989; revised 8 May 1989; .

Address for reprints Yuette Bernard, M.D., Department of Cardiology, University Hospital, 2 Palce Saint-Jacques, 25030 Besascom Cedex, France

Abstract

The aortic valve area was serially evaluated in 45 patients, mean age 78 years, suffering from severe aortic stenosis who underwent percutaneous aortic valvuloplasty. The aortic valve area was calculated from haemodynamic data prior to and immediately after the procedure using the mean gradient. Serial determinations of the aortic valve area were also obtained 1 day before, 1 day after and 2 months after valvuloplasty from the thermodilution cardiac output and Doppler echocardiography mean left ventricle-to-aorta gradient. The mean gradient significantly decreased from 75±24 to 42±16mmHg (P>0.01) when measured from haemodynamic data and from 63±20 to 41±13 mmHg (P>001) when estimated from Doppler-derived data. It rose to 48±15 mmHg at 2 months (NS). The aortic valve area increased significantly from 0–48±0–13 to 0–67±0–29 cm2 (P>0.01) when calculated from haemodynamic data, and from 0–53±0–18 to 0–74±0–23 cm2 (P<001) when estimatedfrom Doppler-derived data. It declined to 0–69±0.27 cm2 at 2 months (NS). Aortic valve area values determined from haemodynamic data and from Doppler-derived data correlated well before valvuloplasty (r=0.80, P>0.01) but poorly afterwards (r=0.57, P>0.01). The aortic valve area was not influenced by valvuloplasty in eight patients. At 2 months, restenosis was apparent in eight patients out of 32 that were re-evaluated. Three patients died within 5 days of the procedure. After an average 12 months 'follow-up, eight more patients died. Symptoms were not influenced or recurred in 17 patients, while 17 others remained improved by at least one NYHA functional class. Seven patients were operated on, and there was one operative death. The calculated aortic valve area was significantly greater at the end of the procedure in the patients with persistent improvement compared with those with a poor result (0–83±0–29 cm2 vs 065±0–14 cm2, P < 0–05). In conclusion, in this study one third of the patients submitted to percutaneous aortic valvuloplasty had no objective improvement in calculated valve area or early restenosis after 2 months. Functional improvement was observed in one third of the patients. Immediate re-estimation of the aortic valve area from haemodynamic data at the end of the procedure may not reflect the actual effect of valvuloplasty on the aortic orifice

Key Words: Aortic stenosis • percutaneous aortic valvuloplasty • Doppler echocardiography • aortic valve area


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer:
Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.