Skip Navigation

European Heart Journal 1990 11(Supplement B):5-9; doi:10.1093/eurheartj/11.suppl_B.5
Copyright © 1990 by the European Society of Cardiology.
This Article
Right arrow Full Text (PDF)
Right arrow E-letters: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Bache, R. J.
Right arrow Articles by Laxson, D. D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bache, R. J.
Right arrow Articles by Laxson, D. D.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© 1990 The European Society of Cardiology

Coronary arteriolar vasoconstriction in myocardial ischaemia: Coronary vasodilator reserve during ischaemia

R. J. Bache and D. D. Laxson

Department of Medicine, University of Minnesota Minneapolis, Minnesota, U.S.A.

Address correspondence to: Robert J. Bache M.D., University of Minnesota, Department of Medicine, Cardiovascular Division, Box 338, UMHC, 420 Delaware Street S.E., Minneapolis, Minnesota 55455, U.S.A.

This study was performed to determine whether vasomotor tone of the coronary resistance vessels limits blood flow to ischaemic myocardium perfused by a stenotic coronary artery during exercise. Studies were performed on dogs in which a hydraulic occluder, in place for ≥14 days, allowed production of a Coronary stenosis, while distal coronary pressure was monitored with a miniature intra-arterial catheter. Treadmill exercise at 6·5km h–1 with a 6% grade resulted in a mean heart rate of 209 ± 4 beats min–1, with mean myocardial blood flow in the normally perfused left ventricular region of 2·90 ± 0·37 ml min–1 g–1. An arterial stenosis that decreased coronary pressure to 40–42 mmHg resulted in a decrease of myocardial blood flow to 1·07 ± 0·19 ml min –1g –1 (P < 0·01), hypoperfusion being most severe in the subendocardium. Intracoronary administration of the selective {alpha}1-adrenergic antagonist, prazosin, resulted in a 50 ± 14% increase in blood flow with no change in perfusion pressure. This increase in flow in response to prazosin was uniform across the left ventricular wall, from epicardium to endocardium. After administration of the selective {alpha}2-adrenergic antagonist, idazoxan, there was a trend toward higher blood flow in the region of myocardium perfused by the stenotic coronary artery, but this change did not achieve statistical significance. These data indicate that residual vasomotor tone may limit blood flow to ischaemic areas of myocardium perfused by a stenotic coronary artery, and that this vasoconstriction is mediated, at least in part, by {alpha}1 adrenergic mechanisms.

Key Words: Coronary stenosis • exercise • vasodilator reserve • coronary vasoconstriction • prazosin • idazoxan


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.