Skip Navigation

European Heart Journal 1992 13(3):348-355;
Copyright © 1992 by the European Society of Cardiology.
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by NIHOYANNOPOULOS, P.
Right arrow Articles by OAKLEY, C. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by NIHOYANNOPOULOS, P.
Right arrow Articles by OAKLEY, C. M.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© 1992 The European Society of Cardiology

Doppler haemodynamic profiles of clinically and echocardiographically normal mitral and aortic valve prostheses

P. NIHOYANNOPOULOS, D. KAMBOUROGLOU, G. ATHANASSOPOULOS, A. NADAZDIN, P. SMITH and C. M. OAKLEY

The Department of Medicine, Clinical Cardiology and the Department of Surgery, Cardiothoracic Unit, Hammersmith Hospital R.P.M.S., London W120NN, U.K.

Received 12 December 1990; revised 11 June 1991; .

Correspondence. Petroa Nihoyannopoulos, MD, Department of Medicine, Clinical Cardiology, Hammersmith Hospital. R.P.M.S., London W120NN, U.K.

Abstract

Doppler echocardiographic studies were performed in 380 consecutive patients with 415 normally functioning artificial valves to establish normal Doppler characteristics for each type of prostheses used in our institution, with particular reference to Starr-Edwards valves, and to serve as control studies for future assessment. None of the patients were in heart failure at the time of the study. Peak transaortic velocities (m.s–1) were higher and effective orifice areas (cm2) smaller in mechanical valves as a whole, when compared with bioprostheses (P < 0.01); 2.7 ± 0.7 and 1.4 ± 0.55 for Starr-Edwards, 2.7±0.6 and 1.5±0.6 for Bjork-Shiley, 1.8±0.1 and 1.5±0.6 for Duromedics and 1.5±0.06 and 2±0.12 for bioprostheses, respectively. In the mitralposition, the average peak diastolic velocities (m.s–1) and pressure halftimes (ms) were higher in mechanical valves, but there was a large overlap between the various types and sizes of prostheses (P = NS), 1.6 ± 0.3 and 98 ± 25 for Starr-Edwards, 1.4 ± 0.3 and 88 ± 26 for Bjork-Shiley, 1.8 ± 0.1 and 75 ± 5 for Duromedics and 1.5 ± 0.3 and 90 ± 20 for bioprostheses, respectively. There was an inverse relation between valve size and pressure halftime for Starr-Edwards prostheses (P <0.01). Doppler flow characteristics in mechanical valves where similar in patients with normal and dysfunctioning prostheses. Valvular or myocardial dysfunction could best be ascertained when early postoperative studies were a vailable for comparison.

No single Doppler measurement was able to separate normal from abnormal prosthetic valve function, so it is recommended that patients have a comprehensive baseline cross-sectional and Doppler examination before postoperative discharge so that each will have a personal ‘Doppler identity’. This will help the recognition of possible future prosthetic valve or myocardial deterioration.

Key Words: Prosthetic valves • Doppler echocardiography


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
HeartHome page
I Ikonomidis, A Tsoukas, F Parthenakis, A Gournizakis, A Kassimatis, L Rallidis, and P Nihoyannopoulos
Four year follow up of aortic valve replacement for isolated aortic stenosis: a link between reduction in pressure overload, regression of left ventricular hypertrophy, and diastolic function
Heart, September 1, 2001; 86(3): 309 - 316.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
D. J. O'Rourke, R. T. Palac, D. J. Malenka, C. A. S. Marrin, B. E. Arbuckle, and J. F. Plehn
Outcome of mild periprosthetic regurgitation detected by intraoperative transesophageal echocardiography
J. Am. Coll. Cardiol., July 1, 2001; 38(1): 163 - 166.
[Abstract] [Full Text] [PDF]



Disclaimer:
Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.