Skip Navigation

European Heart Journal 1993 14(12):1597-1601;
Copyright © 1993 by the European Society of Cardiology.
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by STOJNIC, B. B.
Right arrow Articles by PRCOVIC, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by STOJNIC, B. B.
Right arrow Articles by PRCOVIC, M.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© 1993 The Europen Society of Cardiology

Pulmonary venous flow pattern studied by transoesophageal pulsed Doppler echocardiography in mitral stenosis in sinus rhythm: effect of atrial systole

B. B. STOJNIC, G. S. RADJEN, N. J. PERISIC, P. B. PAVLOVIC, J. J. STOSIC and M. PRCOVIC

Department of Cardiology, Military Medical Academy Belgrade, Yugoslavia

Received 5 January 1993; revised 17 May 1993; .

Correspondence: Bojan B. Stojnic, PhD, Department of Cardiology, Military Medical Academy, Crnotravska 17, 11000 Belgrade, YU.

Abstract

In 13 patients with isolated mitral stenosis in sinus rhythm the pulmonary venous flow was evaluated by transoesophageal pulsed Doppler echocardiography. The patients were divided into two groups according to their mitral valve area (MVA); Group I (MVA<1.5 cm2, n=7 patients); and Group II (MVA> 1.5 cm2, n=6). The patients in group I with haemodynamically significant mitral stenosis had lower velocities of systolic (S), diastolic (D) and atrial retrograde (A) waves of pulmonary venous flow (PVF) compared to milder stenosis (P<0.05). The peak velocity of pulmonary retrograde venous flow at atrial contraction (A) primarily depends on the relative amplitude of the atrial transmitral wave (RA), which is measured from the onset of atrial systole to its peak velocity. We found a highly positive correlation between RA of mitral valve flow (MVF) and A wave of PVF (r=0.87, P<0.001). There was also a highly negative correlation (r=0.80, P<0.001) between A of PVF and ratio of early (PE) to late (PA) velocities of MVF. Therefore, the retrograde A wave of PVF is related to the pressure generated in the left atrium during atrial systole.

Use of pulmonary vein velocities in conjunction with mitral flow velocities can increase our understanding of the haemodynamics of mitral stenosis and provide a new insight into left atrial performance.

Key Words: Transoesophageal echocardiography • mitral stenosis


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
J Am Coll CardiolHome page
T. Tabata, J. D. Thomas, and A. L. Klein
Pulmonary venous flow by doppler echocardiography: revisited 12 years later
J. Am. Coll. Cardiol., April 16, 2003; 41(8): 1243 - 1250.
[Abstract] [Full Text] [PDF]


Home page
Journal of Diagnostic Medical SonographyHome page
A. D. Waggoner and C. A. Baumann
Importance of Recording Pulmonary Venous Flow Velocities With Transthoracic or Transesophagea1 Echocartiography: Clinical Application in Various Cardicac Conditions
Journal of Diagnostic Medical Sonography, January 1, 1997; 13(1): 3 - 15.
[Abstract] [PDF]



Disclaimer:
Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.