Skip Navigation

European Heart Journal 1993 14(4):505-510;
Copyright © 1993 by the European Society of Cardiology.
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by UMANS, V. A.
Right arrow Articles by SERRUYS, P. W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by UMANS, V. A.
Right arrow Articles by SERRUYS, P. W.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© 1993 The European Society of Cardiology

The mechanism of directional coronary atherectomy

V. A. UMANS*, E. HAINE{dagger}, J. RENKIN{dagger}, P. J. DE FEYTER*, W. WIJNS{dagger} and P. W. SERRUYS*,

*Catheterization Laboratory Thoraxcenter, University Hospital Dijkzigt, Erasmus University Rotterdam The Netherlands
{dagger}Division of Cardiology, University of Louvain Medical School Brussels, Belgium

Received 30 January 1992; revised 9 October 1992; .

Correspondence: P. W. Serruys, MD, PhD, Catheterization Laboratory, Thoraxcenter, Erasmus University Rotterdam, P.O. Box 1738, 3000 DR Rotterdam, The Netherlands.

Abstract

An attempt was made to assess the mechanism of directional coronary atherectomy using different methods of analysis. Quantitative coronary angiography was used as the gold standard to assess the immediate results of atherectomy, and a comparative quantitative analysis of atherectomy and balloon angioplasty was made. To determine whether the post-atherectomy cross-sectional area is close to a circle, we compared the area measurements obtained by edge detection with those obtained by videodensitometry. Finally, the extent of a ‘Dotter’ effect was established by quantitative angiography following crossing the stenosis with the atherectomy device. For the purpose of this study, the results of the first 113 successful atherectomy procedures were reviewed. In matched lesions, directional atherectomy induced a greater increase in minimal luminal diameter than balloon angioplasty (1.6 mm vs 0.8 mm; P < 0.0001 However, this luminal improvement is due to a substantial ‘Dotter’ effect induced by the bulky atherectomy device. Following atherectomy, only a slight difference in cross-sectional area measurements between edge detection and videodensitometry (mean difference: 0.28 mm2 was found. Histologic examination of an atherectomized coronary artery showed a near-circular post atherectomy area geometry. In conclusion, directional atherectomy is a very effective device with a substantially better initial result than balloon angioplasty. However, insertion of this bulky device itself causes an important ‘Dotter’effect.

Key Words: Directional coronary atherectomy • quantitative angiography • Dotter effect


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Cardiovasc ResHome page
C. Depre, X. Havaux, J. Renkin, J. L. J. Vanoverschelde, and W. Wijns
Expression of inducible nitric oxide synthase in human coronary atherosclerotic plaque
Cardiovasc Res, February 1, 1999; 41(2): 465 - 472.
[Abstract] [Full Text] [PDF]



Disclaimer:
Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.