Copyright © 1993 by the European Society of Cardiology.
© 1993 The European Society of Cardiology
The mechanism of directional coronary atherectomy



*Catheterization Laboratory Thoraxcenter, University Hospital Dijkzigt, Erasmus University Rotterdam The Netherlands
Division of Cardiology, University of Louvain Medical School Brussels, Belgium
Received 30 January 1992; revised 9 October 1992; .
Correspondence: P. W. Serruys, MD, PhD, Catheterization Laboratory, Thoraxcenter, Erasmus University Rotterdam, P.O. Box 1738, 3000 DR Rotterdam, The Netherlands.
Abstract
An attempt was made to assess the mechanism of directional coronary atherectomy using different methods of analysis. Quantitative coronary angiography was used as the gold standard to assess the immediate results of atherectomy, and a comparative quantitative analysis of atherectomy and balloon angioplasty was made. To determine whether the post-atherectomy cross-sectional area is close to a circle, we compared the area measurements obtained by edge detection with those obtained by videodensitometry. Finally, the extent of a Dotter effect was established by quantitative angiography following crossing the stenosis with the atherectomy device. For the purpose of this study, the results of the first 113 successful atherectomy procedures were reviewed. In matched lesions, directional atherectomy induced a greater increase in minimal luminal diameter than balloon angioplasty (1.6 mm vs 0.8 mm; P < 0.0001 However, this luminal improvement is due to a substantial Dotter effect induced by the bulky atherectomy device. Following atherectomy, only a slight difference in cross-sectional area measurements between edge detection and videodensitometry (mean difference: 0.28 mm2 was found. Histologic examination of an atherectomized coronary artery showed a near-circular post atherectomy area geometry. In conclusion, directional atherectomy is a very effective device with a substantially better initial result than balloon angioplasty. However, insertion of this bulky device itself causes an important Dottereffect.
Key Words: Directional coronary atherectomy quantitative angiography Dotter effect
![]()
CiteULike
Connotea
Del.icio.us What's this?
This article has been cited by other articles:
![]() |
C. Depre, X. Havaux, J. Renkin, J. L. J. Vanoverschelde, and W. Wijns Expression of inducible nitric oxide synthase in human coronary atherosclerotic plaque Cardiovasc Res, February 1, 1999; 41(2): 465 - 472. [Abstract] [Full Text] [PDF] |
||||