Skip Navigation

European Heart Journal 1993 14(Supplement E):61-68; doi:10.1093/eurheartj/14.suppl_E.61
Copyright © 1993 by the European Society of Cardiology.
This Article
Right arrow Full Text (PDF)
Right arrow E-letters: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Weismüller, P.
Right arrow Articles by Hombach, V.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Weismüller, P.
Right arrow Articles by Hombach, V.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© 1993 The European Society of Cardiology

Magnetocardiography: Three-dimensional localization of the origin of ventricular late fields in the signal averaged magnetocardiogram in patients with ventricular late potentials

P. Weismüller*,, K. Abraham-Fuchs{dagger}, R. Killmann*, P. Richter*, W. Härer{dagger}, M. Höher*, M. Kochs*, T. Eggeling* and V. Hombach*

* Department of Cardiology, Angiology, Pneumology and Nephrology, University of Ulm Ulm, Germany
{dagger} Siemens Medical Engineering Group Henkestr. 127, 8520 Erlangen, Germany

Correspondence: Dr Peter Weismüller, Department of Cardiology, Angiology, Pneumology and Nephrology. University of Ulm, Robert Koch Straβe 8, 7900 Ulm, Germany.

The purpose of this study was to detect ventricular late fields recorded by a biomagnetic multichannel system in patients with ventricular late potentials and to determine the site of these ventricular late fields non-invasively in three dimensions.

Biomagnetic signals of sinus beats during a 5-min acquisition period simultaneously recorded by a 37-channel system Krenikon were averaged in all channels. Ventricular late fields were determined in each channel according to the algorithm of Simson for ECG data. For the localization process, baseline correction from the averaged non-filtered signals was performed at the end of the QRS complex under visual control. The single current dipole model within the homogeneous half-space was applied.

Eight patients post myocardial infarction with ventricular late potentials (four with recurrent sustained ventricular tachycardia) and four healthy individuals were examined.

In the normal subjects, no ventricular late fields were detected. However, ventricular late fields were found in all patients, and were localized in six patients within the border zone of myocardial infarction. In the four patients with ventricular tachycardia, a spatial coincidence of the site of origin of ventricular late fields and the site of origin of ventricular tachycardia determined by catheter mapping was found in two.

It is concluded that magnetocardiography is able to detect ventricular late fields and can be used to determine their site of origin.

Key Words: Ventricular late fields • ventricular late potentials • magnetocardiography • MCG • ventricular tachycardia • three-dimensional non-invasive localization • signal averaging


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.