Skip Navigation

European Heart Journal 1994 15(2):189-199;
Copyright © 1994 by the European Society of Cardiology.
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by MÄKIJÄRVI, M.
Right arrow Articles by KATILA, T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by MÄKIJÄRVI, M.
Right arrow Articles by KATILA, T.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© 1994 The European Society of Cardiology

High-resolution and signal-averaged electrocardiography to separate post-myocardial infarction patients with and without ventricular tachycardia

M. MÄKIJÄRVI, J. MONTONEN*, L. TOIVONEN, M. LEINIö*, P. SILTANEN and T. KATILA*

From the Helsinki University Central Hospital, First Department of Medicine, Cardiovascular Laboratory SF-00290 Helsinki Finland
*Helsinki University of Technology, Department of Technical Physics, Laboratory of Biomedical Engineering SF-02150 Espoo, Finland

Received 18 January 1993; revised 27 September 1993; .

Coresspondence: Markku Mäkijärvi, MD, Helsinki University Central Hospital, First Department of Medicine, Cardiovascular Laboratory, Haartmaninkatu 4, SF-00290 Helsinki, Finland

Abstract

High-resolution and signal-averaged ECG, 24 h Holter recording and ejection fraction were used to separate post-myocardial infarction patients with and without ventricular tachycardia (VT) among 150 individuals: 26 patients with an old myocardial infarction and documented sustained VT, 104 patients with an acute myocardial infarction without sustained VT, who were followed-up for 2 years, and 20 healthy volunteers. Bipolar orthogonal XYZ leads were recorded, high-pass filtered at cut-off frequencies of 25, 40, 60, 80 and 100 Hz, and combined to vector magnitude {surd}x2 + Y2+ Z2. The filtered QRS duration, the root-mean-square voltages of different time intervals and the durations of low amplitude signals under different thresholds, both from the initial and terminal QRS, were calculated. The sensitivity and specificity of each parameter alone and in every combination of two, three and four parameters (17 million different combinations) were computed both from non-averaged and averaged data. The best separation was achieved by 12 combinations all including four signal-averaged ECG parameters, with a sensitivity of 81% and a specificity of 79%. The parameters represented most were: filtered QRS duration at 25 Hz, RMS voltage of the last 50 ms at 25 Hz, terminal LAS duration at 80 Hz, and RMS voltage of the last 20 ms at 80 Hz. Parameters of the initial QRS complex did not improve either the sensitivity or the specificity of the method. In logistic regression analysis, the best combinations of four signal-averaged ECG parameters separated VT patients better (P<0·001) than non-sustained ventricular tachycardia at Holter (P=0·001); left ventricular ejection fraction (P=0·01) or age (P=0·006). Parameters calculated from averaged data gave better results than parameters calculated from non-averaged data.

Key Words: Signal-averaged electrocardiography • high-resolution electrocardiography • myocardial infarction • ventricular tachycardia


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer:
Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.