Skip Navigation

European Heart Journal 1995 16(10):1425-1429;
Copyright © 1995 by the European Society of Cardiology.
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by WHITE, P. A.
Right arrow Articles by REDINGTON, A. N.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by WHITE, P. A.
Right arrow Articles by REDINGTON, A. N.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© 1995 The European Society of Cardiology

The determination of volume of right ventricular casts using a conductance catheter

P. A. WHITE, A. J. BISHOP, B. CONROY*, P. J. OLDERSHAW and A. N. REDINGTON

Royal Brompton Hospital London
*Maxillo-Facial Laboratory, Queen Mary's University Hospital London

revised 7 November 1994; accepted 21 December 1994.

Correspondence: Dr A. N. Redington, Department of Paediatric Cardiology, Royal Brompton Hospital, Sydney Street, London SW3 6NP.

Abstract

Conductance catheters were used to assess the volume of right ventricular models made from post-mortem casts. Models were made from silastic rubber and filled with saline. The correlation between volume assessed by conductance catheter and real volume was investigated as saline was withdrawn from, and injected into, five models. The mean regression between real and conductance-derived volume was 1.05 (SE 0.04 mean R2 0.94 SE 0.02) with Y-intercept {theta} 0.25 ml SE 1.72. Parallel wall conductance was assessed through the tricuspid orifice sealed with human tricuspid tissue, or left open, and found to be negligible. There was no difference between volumes measured by a catheter through either the pulmonary or tricuspid orifice. We conclude that conductance catheters are suitable for the assessment of right ventricular volume, despite the complex geometry.

Key Words: Conductance catheter • right ventricle


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
M. H. D. Danton, G. F. Greil, J. G. Byrne, M. Hsin, L. Cohn, and S. E. Maier
Right ventricular volume measurement by conductance catheter
Am J Physiol Heart Circ Physiol, October 1, 2003; 285(4): H1774 - H1785.
[Abstract] [Full Text] [PDF]


Home page
Cardiovasc ResHome page
L. Kornet, J.J. Schreuder, E.T. van der Velde, and J.R.C. Jansen
The volume-dependency of parallel conductance throughout the cardiac cycle and its consequence for volume estimation of the left ventricle in patients
Cardiovasc Res, September 1, 2001; 51(4): 729 - 735.
[Abstract] [Full Text] [PDF]


Home page
Cardiovasc ResHome page
L Kornet, J.J Schreuder, E.T van der Velde, J Baan, and J.R.C Jansen
A new approach to determine parallel conductance for left ventricular volume measurements
Cardiovasc Res, December 1, 2000; 48(3): 455 - 463.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
A. Bishop, P. White, P. Groves, R. Chaturvedi, C. Brookes, A. Redington, and P. Oldershaw
Right ventricular dysfunction during coronary artery occlusion: pressure-volume analysis using conductance catheters during coronary angioplasty
Heart, November 1, 1997; 78(5): 480 - 487.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
R. R. Chaturvedi, P. J. Kilner, P. A. White, A. Bishop, R. Szwarc, and A. N. Redington
Increased Airway Pressure and Simulated Branch Pulmonary Artery Stenosis Increase Pulmonary Regurgitation After Repair of Tetralogy of Fallot: Real-Time Analysis With a Conductance Catheter Technique
Circulation, February 4, 1997; 95(3): 643 - 649.
[Abstract] [Full Text]



Disclaimer:
Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.