Skip Navigation

European Heart Journal 1995 16(3):383-393;
Copyright © 1995 by the European Society of Cardiology.
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by ZHOU, Y.-Q.
Right arrow Articles by MATRE, K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by ZHOU, Y.-Q.
Right arrow Articles by MATRE, K.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© 1995 The European Society of Cardiology

Velocity distributions in the left ventricular outflow tract in patients with valvular aortic stenosis

Effect on the measurement of aortic valve area by using the continuity equation

Y.-Q. ZHOU, S. FAERESTRAND and K. MATRE

Medical Department A, University of Bergen, Haukeland Hospital Bergen, Norway

accepted 11 August 1994.

Correspondence. Svein Facrestrand, MD, PhD, Department of Heart Disease. University of Bergen, Haukeland Hospital. N-5021 Bergen. Norway.

Abstract

The cross-sectional velocity distribution in the left ventricular outflow tract was studied in 40 patients with valvular aortic stenosis. Doppler colour flow mapping and a time-interpolation method were used to construct the cross-sectional velocity and time-velocity integral (TVI) profiles at different levels. By using pulsed Doppler, the subaorticflow velocity was sampled from the anterior, middle and posterior regions along the diameter of the left ventricular outflow tract (at 0.5 to 1.0 cm proximal to the aortic anulus) in the apical long axis view. Thus, for each patient, three aortic valve areas were calculated by using the continuity equation. Each patient was assigned to one oft/tree subgroups according to the left ventricular ejection fraction (EF): subgroup I with EF≤25% (n=10), subgroup II with 25%<EF≤50% (n=17) and subgroup III with EF>50% (n = 13). Velocity distributions in the three subgroups were compared to each other. Results: (1) The velocity distribution in the left ventricular outflow tract was skewed with the highest velocities and TVIs along the anterior wall and septum. The skewness of the velocity distribution was more pronounced in the apical long axis view than in the four chamber view (P<0.05). The extent of skewness of the TVI profile was positively correlated to the left ventricular EF both in the long axis view (r=0.63; P<0.001) and in the four chamber view (r=0–57; P<0.001). (2) Pulsed Doppler sampling from different regions along the diameter produced different TVIs, and therefore yielded significantly different calculated aortic valve areas, especially in subgroup III.

Due to the skewness of the velocity distribution in the left ventricular outflow tract, location of the pulsed Doppler sample volume significantly affects the accuracy of aortic valve area calculation by using the continuity equation, especially in patients with relatively high left ventricular EF. In patients with low EF, selection of pulsed Doppler sampling site is less important.

Key Words: Velocity distribution • Doppler ultrasound • valvular aortic stenosis • continuity equation


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Eur J EchocardiogrHome page
R. Moreno, J. Zamorano, C. Almeria, J. A. Perez-Gonzalez, L. Mataix, J. L. Rodrigo, D. Herrera, A. Aubele, L. Perez de Isla, E. De Marco, et al.
Isovolumic Contraction Time by Pulsed-Wave Doppler Tissue Imaging in Aortic Stenosis
Eur J Echocardiogr, December 1, 2003; 4(4): 279 - 285.
[Abstract] [Full Text] [PDF]


Home page
Card Surg AdultHome page
T. Mihaljevic, S. Paul, L. H. Cohn, and A. Wechsler
Pathophysiology of Aortic Valve Disease
Card. Surg. Adult, January 1, 2003; 2(2003): 791 - 810.
[Full Text]


Home page
J Am Coll CardiolHome page
T. Shiota, M. Jones, S. Aida, M. Chikada, H. Tsujino, T. El-Kadi, and D. J. Sahn
Validation of the accuracy of both right and left ventricular outflow volume determinations and semiautomated calculation of shunt volumes through atrial septal defects by digital color Doppler flow mapping in a chronic animal model
J. Am. Coll. Cardiol., August 1, 1999; 34(2): 587 - 593.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
K Dennig, H J Nesser, D Hall, H U Haase, and A Schömig
Determination of prestenotic flow volume using an automated method based on colour Doppler imaging for evaluating orifice area by the continuity equation: validation in a pulsatile flow model
Heart, April 1, 1998; 79(4): 324 - 330.
[Abstract] [Full Text]



Disclaimer:
Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.