Skip Navigation

European Heart Journal 1995 16(9):1231-1233;
Copyright © 1995 by the European Society of Cardiology.
This Article
Right arrow Full Text (PDF)
Right arrow E-letters: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by D'AVILA, A.
Right arrow Articles by BRUGADA, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by D'AVILA, A.
Right arrow Articles by BRUGADA, P.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© 1995 The European Society of Cardiology

At what time are implantable defibrillator shocks delivered?

Evidence for individual circadian variance in sudden cardiac death

A. D'AVILA, F. WELLENS, E. ANDRIES and P. BRUGADA

Cardiovascular Research and Teaching Institute Aalst Cardiovascular Center, O.L. V. Hospital Aalst, Belgium

revised 27 September 1994; accepted 28 October 1994.

Correspondence: Pedro Brugada, MD, Professor of Cardiology, Cardiovascular Research and Teaching Institute Aalst, Cardiovascular Center, OLV Hospital, Moorselbaan, 164-9300 Aalst, Belgium.

Abstract

Background: As in myocardial infarction and transient ischaemia, out-of-hospital sudden cardiac death has an increased morning incidence. However, sudden death occurring in hospital is evenly distributed over the 24 h period suggesting that there might be subgroups of patients with atypial circadian patterns of sudden death. Patients who received an implantable defibrillator constitute an ideal group for studies of circadian patterns of sudden death since this generation of devices are able to store the exact time when defibrillation occurred

Methods: The distribution of sudden death aborted by the implantable defibrillator was analysed during the 24 h period for 87 presumed appropriate shocks delivered in a group of 22 patients, 18 men and four women, 58.7 ± 11.9 years old and with a mean left ventricular ejection fraction of 39.4 ± 17.6%.

Results: Each patient received an average of 4.42 ± 3.04 shocks during a mean follow-up of 9.4 ± 5.6 months. Apart from a clear tendency for shocks to occur during the morning hours (42% of total shocks), five of 16 patients who received multiple shocks also showed a trend to repeat the shocks around the same period during the day.

Conclusion: Our results support the accepted view that changes in autonomic tone in the early morning play a role in the circadian variations of sudden death. Sudden death not only occurs more frequently in the morning hours, but it also clusters in certain periods for individual patients.

Key Words: Sudden death • circadian variance • implantable defibrillator


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
J Am Coll CardiolHome page
A. Englund, S. Behrens, K. Wegscheider, E. Rowland, and for the European 7219 Jewel Investigators
Circadian variation of malignant ventricular arrhythmias in patients with ischemic and nonischemic heart disease after cardioverter defibrillator implantation
J. Am. Coll. Cardiol., November 1, 1999; 34(5): 1560 - 1568.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
A. d'Avila, P. Brugada, A. P. Hallstrom, M. Peckova, C. E. Fahrenbruch, and L. A. Cobb
Individual Circadian Variation and Sudden Death • Response
Circulation, July 27, 1999; 100 (4): 446 - 449.
[Full Text] [PDF]


Home page
CirculationHome page
C. E. Lavery, M. A. Mittleman, M. C. Cohen, J. E. Muller, and R. L. Verrier
Nonuniform Nighttime Distribution of Acute Cardiac Events : A Possible Effect of Sleep States
Circulation, November 18, 1997; 96(10): 3321 - 3327.
[Abstract] [Full Text]


Home page
CirculationHome page
D. Mehta, J. Curwin, J. A. Gomes, and V. Fuster
Sudden Death in Coronary Artery Disease : Acute Ischemia Versus Myocardial Substrate
Circulation, November 4, 1997; 96(9): 3215 - 3223.
[Full Text]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.