Skip Navigation

European Heart Journal 1996 17(4):574-582;
Copyright © 1996 by the European Society of Cardiology.
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Sutton, R.
Right arrow Articles by Bourgeois, I.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sutton, R.
Right arrow Articles by Bourgeois, I.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© 1996 The European Society of Cardiology

Cost benefit analysis of single and dual chamber pacing for sick sinus syndrome and atrioventricular block

An economic sensitivity analysis of the literature

R. Sutton*, and I. Bourgeois{dagger}

*Royal Brompton Hospital London, U.K.
{dagger}Medtronic, Bakken Research Center B.V. Maastricht, The Netherlands

Received 19 November 1995; accepted 8 December 1995.

Correspondence: Dr R. Sutton, Royal Brompton Hospital, Sydney Street, London SW3 6NP, U.K.

Abstract

The benefits of dual (DDD) over single chamber pacing (VVI) have been demonstrated in haemodynamics, exercise capacity, quality of life and reduced complications in atrioventncular block and sick sinus syndrome.

The literature was reviewed to provide complication rates for dual and VV1 pacing. Cost calculations were based on United Kingdom 1991 prices. Over a 10-year period, a computer model calculated the incidence and prevalence of atrial fibrillation, stroke, permanent disability, heart failure and mortality in six patient categories: sick sinus syndrome paced VVI, sick sinus syndrome upgraded to DDD, sick sinus syndrome paced DDD from outset, atrioventricular block paced VYI and those upgraded to DDD and atrio ventricular block paced initially DDD. Calculations were based on intention to treat.

The 10 year survival with DDD vs YVI pacing was 71% vs 57% in sick sinus syndrome and 61% vs 51%, respectively, in atrioventricular block. In both indications the prevalence of heart failure in the 10 year survivors was 600 lower with DDD pacing. In sick sinus syndrome patients paced VVI, 36% had severe disability while only 8% experienced this with DDD pacing. For atrioventricular block the figures were, respectively, 22% vs 3%. The difference in 10 year cumulative cost between VVI and DDD is 13 times the purchase price of a VVI pulse generator for sick sinus syndrome and 7 times for atrioventricular block. In the third year after implantation the cumulative costs of DDD were lower than for VVI for both indications.

Dual chamber pacing for both indications, sick sinus syn drome and atrioventricular block, is both clinically and cost effective.

Key Words: Cost benefit analysis • atrioventricular block • sick sinus syndrome • dual chamber pacing • VVI pacing • atrial fibrillation • stroke • permanent disability • heart failure • mortality


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
EuropaceHome page
J. Caro, A. Ward, and J. Moller
Modelling the health benefits and economic implications of implanting dual-chamber vs. single-chamber ventricular pacemakers in the UK
Europace, June 1, 2006; 8(6): 449 - 455.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
G. Boriani, L. Rusconi, M. Biffi, L. Pavia, M. Sassara, D. Malfitano, M. G. Bongiorni, L. Padeletti, I. Filice, D. Sanfelici, et al.
Role of ventricular autocapture function in increasing longevity of DDDR pacemakers: a prospective study.
Europace, March 1, 2006; 8(3): 216 - 220.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
D B Shaw, J I Gowers, C A Kekwick, K H J New, and A W T Whistance
Is Mobitz type I atrioventricular block benign in adults?
Heart, February 1, 2004; 90(2): 169 - 174.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
J.C. Daubert and C. Leclercq
Upgrading from ventricular to physiological pacing: is it worth it?
Eur. Heart J., March 2, 2002; 23(6): 437 - 441.
[Full Text] [PDF]


Home page
Eur Heart JHome page
U.K.H Wiegand, J Potratz, F Bode, R Schreiber, H Bonnemeier, W Peters, and H.A Katus
Cost-effectiveness of dual-chamber pacemaker therapy: does single lead VDD pacing reduce treatment costs of atrioventricular block?
Eur. Heart J., January 2, 2001; 22(2): 174 - 180.
[Abstract] [PDF]


Home page
EuropaceHome page
A. Proclemer, P. Della Bella, D. Facchin, L. Fattore, C. Carbucicchio, C. Tondo, M. Lunati, M. R. Vecchi, E. Petz, and M. Zecchin
Indications for dual-chamber cardioverter defibrillators at implant and at 1 year follow-up: a retrospective analysis in the single-chamber defibrillator era
Europace, January 1, 2001; 3(2): 132 - 135.
[Abstract] [PDF]


Home page
EuropaceHome page
J. Carlsson, S. Miketic, G. Dees, S. Haun, A. Cuneo, and U. Tebbe
Stroke prevention practices in patients with atrial fibrillation and pacemaker therapy: Evidence for under-use of anticoagulation
Europace, January 1, 2000; 2(2): 115 - 118.
[Abstract] [PDF]


Home page
Eur Heart JHome page
M. Vassolo and G.A. Lamas
Dual-chamber vs ventricular pacing in the elderly: quality of life and clinical outcomes
Eur. Heart J., November 2, 1999; 20(22): 1607 - 1608.
[PDF]


Home page
HeartHome page
H J MARSHALL, M D GAMMAGE, and M J GRIFFITH
AAI pacing for sick sinus syndrome: first choice on all counts
Heart, October 1, 1998; 80(4): 315 - 316.
[Full Text]


Home page
HeartHome page
K W Clarke, D T Connelly, and R G Charles
Single chamber atrial pacing: an underused and cost-effective pacing modality in sinus node disease
Heart, October 1, 1998; 80(4): 387 - 389.
[Abstract] [Full Text]


Home page
CirculationHome page
E. Ovsyshcher, D. L. Hayes, and S. Furman
Dual-Chamber Pacing Is Superior to Ventricular Pacing : Fact or Controversy?
Circulation, June 16, 1998; 97(23): 2368 - 2370.
[Full Text] [PDF]


Home page
The ANNALS of the American Academy of Political and Social ScienceHome page
A. BRICHTA
The New Premier-Parliamentary System in Israel
The ANNALS of the American Academy of Political and Social Science, January 1, 1998; 555(1): 180 - 192.
[Abstract]



Disclaimer:
Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.