Skip Navigation

European Heart Journal 1996 17(5):721-730;
Copyright © 1996 by the European Society of Cardiology.
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Kearney, P.
Right arrow Articles by Meyer, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kearney, P.
Right arrow Articles by Meyer, J.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The European Society of Cardiology

Interventional cardiology

Differences in the morphology of unstable and stable coronary lesions and their impact on the mechanisms of angioplasty. An in vivo study with intravascular ultrasound

P. Kearney, R. Erbel{dagger}, H. J. Rupperect, J. Ge, L. Koch, T. Voigtländer, P. Stähr, G. Görge{dagger} and J. Meyer

II. Medizinische Klinik und Poliklinik, Johannes Gutenberg University Langenbeckstrasse 1, 55101 Mainz, Germany
{dagger}Abteilung Kardiologie, Universitätsklinikum Essen Hufelandsirasse 55, 45122 Essen, Germany

Received 25 September 1995; accepted 25 October 1995.

Correspondence: P. Kearney, Department of Cardiology, Western General Hospital, Crewe Road South, Edinburgh EH4 2XU, Scotland

Abstract

The aim of this study was to compare the morphology of stable and unstable coronary lesions using intravascular ultrasound in patients undergoing coronary balloon angioplasty and to determine whether lesion morphology had any influence on the mechanism of balloon angioplasty.

Thirty three (15 stable and 18 unstable) patients undergoing single lesion percutaneous transluminal coronary angio plasty were studied with intravascular ultrasound before and after intervention. All examinations, recorded on S-VHS video tape, were studied off-line and matched sites from the point of minimum lumen area after the procedure and the corresponding site prior to intervention were com pared. The morphology of lesions before intervention was noted and the mechanisms of angioplasty (vessel stretch, lesion remodelling and lesion tears) were determined by comparing pre- and post-interventional morphology and dimensions.

The only significant morphological difference between stable and unstable lesions was the presence of a demarcated inner layer in unstable lesions, delimited by a fine circumferential line. This pattern was noted in 77% (14/18) of unstable lesions and in 7% (1/15) of stable lesions (P<0·0l). Unstable lesions tended to have more echolucent zones than stable lesions (72% (13/18) vs 46% (7/15), P=0·13) The mechanisms of angioplasty were also found to differ. Whereas lesion remodelling (or ‘compression’) was seen in 77% (14/18) of unstable lesions, it occurred in only 13% (2/15) of stable lesions and mean lesion cross- sectional area reduction was greater in unstable lesions, –14·8±8·3% (2·1+1·3 mm2) compared to stable lesions, –4sup1+8·4% (0·42+0·9 mm P<0·0l. In contrast, vessel stretch was seen more frequently in stable lesions (73%, 11/15) compared to unstable lesions (22%, 4/18) P<0·0l and the mean increase in vessel cross-sectional area was +13·5±6·8 (1·6±0·9 mm2 in stable lesions compared to +5·5±5·6% (0·8+0·9 mm2 in unstable lesions, P<0·01. Lesion tear was present to a similar degree in both groups of patients.

In this observational study we found a set of echographic markers that distinguished unstable lesions. The mechanisms of angioplasty differed between stable and unstable angina, with greater lesion remodelling seen in unstable lesions and vessel stretch in stable lesions. Taken together, these findings suggest that the markers we describe may be echographic indicators of mural thrombus.

Key Words: Unstable angina • intravascular ultrasound • PTCA • thrombus


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
CirculationHome page
K. Fujii, Y. Kobayashi, G. S. Mintz, H. Takebayashi, G. Dangas, I. Moussa, R. Mehran, A. J. Lansky, E. Kreps, M. Collins, et al.
Intravascular Ultrasound Assessment of Ulcerated Ruptured Plaques: A Comparison of Culprit and Nonculprit Lesions of Patients With Acute Coronary Syndromes and Lesions in Patients Without Acute Coronary Syndromes
Circulation, November 18, 2003; 108(20): 2473 - 2478.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
A. Maehara, G. S. Mintz, A. B. Bui, O. R. Walter, M. T. Castagna, D. Canos, A. D. Pichard, L. F. Satler, R. Waksman, W. O. Suddath, et al.
Morphologic and angiographic features of coronary plaque rupture detected by intravascular ultrasound
J. Am. Coll. Cardiol., September 4, 2002; 40(5): 904 - 910.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
C. von Birgelen, W. Klinkhart, G. S. Mintz, A. Papatheodorou, J.o. Herrmann, D. Baumgart, M. Haude, H. Wieneke, J. Ge, and R. Erbel
Plaque distribution and vascular remodeling of ruptured and nonruptured coronary plaques in the same vessel: an intravascular ultrasound study in vivo
J. Am. Coll. Cardiol., June 1, 2001; 37(7): 1864 - 1870.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
G. S. Mintz, S. E. Nissen, W. D. Anderson, S. R. Bailey, R. Erbel, P. J. Fitzgerald, F. J. Pinto, K. Rosenfield, R. J. Siegel, E. M. Tuzcu, et al.
American College of Cardiology clinical expert consensus document on standards for acquisition, measurement and reporting of intravascular ultrasound studies (ivus): A report of the american college of cardiology task force on clinical expert consensus documents developed in collaboration with the european society of cardiology endorsed by the society of cardiac angiography and interventions
J. Am. Coll. Cardiol., April 1, 2001; 37(5): 1478 - 1492.
[Full Text] [PDF]


Home page
CirculationHome page
S. E. Nissen and P. Yock
Intravascular Ultrasound : Novel Pathophysiological Insights and Current Clinical Applications
Circulation, January 30, 2001; 103(4): 604 - 616.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
C von Birgelen, W Klinkhart, G S Mintz, H Wieneke, D Baumgart, M Haude, T Bartel, S Sack, J Ge, and R Erbel
Size of emptied plaque cavity following spontaneous rupture is related to coronary dimensions, not to the degree of lumen narrowing. A study with intravascular ultrasound in vivo
Heart, November 1, 2000; 84(5): 483 - 488.
[Abstract] [Full Text]


Home page
CirculationHome page
M. R. Ward, G. Pasterkamp, A. C. Yeung, and C. Borst
Arterial Remodeling : Mechanisms and Clinical Implications
Circulation, September 5, 2000; 102(10): 1186 - 1191.
[Full Text] [PDF]


Home page
HeartHome page
P C Smits, G Pasterkamp, M A Q. van Ufford, F D Eefting, P R Stella, P P T de Jaegere, and C Borst
Coronary artery disease: arterial remodelling and clinical presentation
Heart, October 1, 1999; 82(4): 461 - 464.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
M Gyongyosi, P Yang, A Hassan, F Weidinger, H Domanovits, A Laggner, and D Glogar
Arterial remodelling of native human coronary arteries in patients with unstable angina pectoris: a prospective intravascular ultrasound study
Heart, July 1, 1999; 82(1): 68 - 74.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
J Ge, F Chirillo, J Schwedtmann, G Görge, M Haude, D Baumgart, V Shah, C von Birgelen, S Sack, H Boudoulas, et al.
Screening of ruptured plaques in patients with coronary artery disease by intravascular ultrasound
Heart, June 1, 1999; 81(6): 621 - 627.
[Abstract] [Full Text]



Disclaimer:
Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.