Skip Navigation

European Heart Journal 1996 17(7):1092-1102;
Copyright © 1996 by the European Society of Cardiology.
This Article
Right arrow FREE Full Text (PDF) Freely available
Right arrow E-letters: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Willems, S.
Right arrow Articles by Borggrefe, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Willems, S.
Right arrow Articles by Borggrefe, M.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© 1996 The European Society of Cardiology

Temperature-controlled slow pathway ablation for treatment of atrioventricular nodal reentrant tachycardia using a combined anatomical and electrogram guided strategy

S. Willems, H. Shenasa, H. Kottkamp, X. Chen, G. Hindricks, S. Yli-Mäyry, W. Haverkamp, T. Wichter, B. Rotman, G. Breithardt and M. Borggrefe

Hospital of the Westfälische Wilhelms University of Münster, Department of Cardiology and Angiology and Institute for Research in Arteriosclerosis Münster, Germany

revised 12 December 1995; accepted 5 January 1996.

Correspondence: Stephan Willems, MD, Martin Borggrefe, MD, Innere Medizin C, Uni Klinik Münster, D-48129 Münster, Germany

Abstract

AIMS: Anatomical and electrogram-guided techniques have been used separately for slow pathway ablation in atrioventricular nodal reentrant tachycardia. The aims of the present study were to analyse electrogram characteristics of target sites and biophysical parameters using a combined anatomical and electrogram-guided technique for temperature-controlled radiofrequency catheter ablation of the slow pathway.

METHODS AND RESULTS: Using a temperature-controlled (pre-selected 60 °C) catheter system, 53 patients with atrioventricular nodal reentrant tachycardia underwent slow pathway radiofrequency ablation. Mapping was started posteroseptally near the coronary sinus ostium and continued towards the midseptal area if needed. The longest and latest atrial electrograms with an atrioventricular ratio of ≤0·5 were targeted. After a median of two pulses (mean 2·36 ± 1·33), atrioventricular nodal reentrant tachycardia was rendered non-inducible in all patients without complications. Successful sites had longer atrial electrograms (78·8 ± 9·8 vs 67·6 ± 13·3 ms, P<0·003) and larger ventricular electrogram amplitudes (92·4 ± 51·2 vs 63·1 ± 28·8 mV, P<0·05) than the failed sites, but had a similar atrioventricular ratio, P-A interval and atrial electrogram amplitude. Overall, an atrial electrogram duration of ≥70 ms was associated with effective radiofrequency delivery, with 86% sensitivity and 62% specificity. The achieved temperature maximum was 62·3 ± 9·8 °C at successful and 58·8 ± 9·0 °C at unsuccessful sites (ns). There was no significant difference between successful and unsuccessful applications with respect to power output, impedance and total delivery energy. During a pre-discharge study, three patients with inducible atrioventricular nodal reentrant tachycardia underwent a repeat ablation. During 12·3 ± 2·5 (6–15) months of follow-up, three others had a clinical recurrence of atrioventricular nodal reentrant tachycardia.

CONCLUSIONS: The combined approach for slow pathway ablation is highly effective, requiring a low number of radiofrequency pulses. Long atrial activation time seems to be the most powerful predictor of success. Similar catheter tip temperature levels during successful and unsuccessful radiofrequency applications indicate that suboptimal selection of target sites rather than ineffective heating due to poor catheter tissue coupling is responsible for unsuccessful energy delivery.

Key Words: Catheter ablation • atrioventricular nodal reentrant tachycardia • slow pathway • supraventricular tachycardia • temperature control


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Eur Heart JHome page
S. Willems, T. Rostock, M. Shenasa, C. Weiss, T. Risius, R. Ventura, M. Hoffmann, and T. Meinertz
Sub-threshold stimulation in variants of atrioventricular nodal re-entrant tachycardia: electrophysiological effects and impact for guidance of slow pathway ablation
Eur. Heart J., July 2, 2004; 25(14): 1249 - 1256.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
S. Willems, C. Weiss, M. Shenasa, R. Ventura, M. Hoffmann, and T. Meinertz
Optimized mapping of slow pathway ablation guided by subthreshold stimulation: a randomized prospective study in patients with recurrent atrioventricular nodal re-entrant tachycardia
J. Am. Coll. Cardiol., May 1, 2001; 37(6): 1645 - 1650.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
J.R. Clague, N. Dagres, H. Kottkamp, G. Breithardt, and M. Borggrefe
Targeting the slow pathway for atrioventricular nodal reentrant tachycardia: initial results and long-term follow-up in 379 consecutive patients
Eur. Heart J., January 1, 2001; 22(1): 82 - 88.
[Abstract] [PDF]


Home page
Eur Heart JHome page
Y.-G. Li, G. Gronefeld, B. Bender, C. Machura, and S.H. Hohnloser
Risk of development of delayed atrioventricular block after slow pathway modification in patients with atrioventricular nodal reentrant tachycardia and a pre-existing prolonged PR interval
Eur. Heart J., January 1, 2001; 22(1): 89 - 95.
[Abstract] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.