European Heart Journal 1997 18(4):625-630;
Copyright © 1997 by the European Society of Cardiology.
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Galal, O.
Right arrow Articles by Schmaltz, A. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Galal, O.
Right arrow Articles by Schmaltz, A. A.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© 1997 The European Society of Cardiology

Problems encountered during introduction of Gianturco coils for transcatheter occlusion of the patent arterial duct

O. Galal, M. de Moor, F. Fadley, S. Qureshi*, S. Naffa{dagger}, S. Oufi, M. Suhl, F. Abbag and A. A. Schmaltz{dagger}

King Faisal Specialist Hospital and RC
*Guy's Hospital St. Thomas Street, London SE1 9RT, U.K.
{dagger}University of Essen Germany

revised 25 June 1996; accepted 2 July 1996.

Correspondence: Mohammed Omar Galal MD, PhD, Section Pediatric Cardiology, Department of Cardiovascular Diseases, MBC 16, King Faisal Specialist Hospital and RC, PO Box 3354, RIYADH 11211, Saudi Arabia

Abstract

OBJECTIVE: To define the problems encountered during transcatheter occlusion of the patent arterial duct using Gianturco coils.

METHODS: Between January 1994 and November 1995, 93 patients were admitted in whom it was intended to occlude the patent arterial duct using Gianturco coils. Anterograde transcatheter coil occlusion was performed via the femoral vein in 81 patients. In the remaining 12 the procedure was done via the femoral artery.

RESULTS: Coils were implanted successfully in 82/93 (88%) patients. In 11 patients the procedure was a failure. In 19/93 patients (20%), inadvertent embolization of the coil occurred. The coils were retrieved in all except one patient. In 17 of these patients, new coils were then reimplanted successfully. Doppler echocardiography after the procedure showed that in 9/82 (11%) patients the left pulmonary artery Doppler peak velocity exceeded 1·5 m. s –1(mean 1·2 m. s.–1) raising concern about left pulmonary artery branch stenosis. The complete occlusion rate at discharge from hospital was 72/82 (88%). Follow-up ranges from 1 day to 14 months (mean 2/12 months) in the 82 patients in whom successful deployment of coils was possible. In two patients, the arterial duct became occluded at followup. One additional patient had complete occlusion after reocclusion using another coil. Thus, after short-term follow-up a total of 75/82 patients (91·4%) have a completely occluded arterial duct after coil implantation.

CONCLUSION: Transcatheter occlusion of the patent arterial duct using Gianturco coils is an effective and safe technique. In the learning curve there is a relatively high rate of inadvertent embolization, but the coils can be retrieved in the vast majority of patients. The complication rate is offset by the high early occlusion rate and the inexpensiveness of the procedure.

Key Words: Gianturco coils • transcatheter occlusion • patent arterial duct


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Asian Cardiovasc. Thorac. Ann.Home page
M O. Galal, M. Amin, A. Hussein, A. Kouatli, J. Al-Ata, and A. Jamjoom
Left Ventricular Dysfunction after Closure of Large Patent Ductus Arteriosus
Asian Cardiovasc Thorac Ann, March 1, 2005; 13(1): 24 - 29.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
B. D. Thanopoulos, F. A. Hakim, A. Hiari, Y. Goussous, E. Basta, A. A. Zarayelyan, and G. S. Tsaousis
Further experience with transcatheter closure of the patent ductus arteriosus using the Amplatzer duct occluder
J. Am. Coll. Cardiol., March 15, 2000; 35(4): 1016 - 1021.
[Abstract] [Full Text] [PDF]



Disclaimer:
Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.