Copyright © 1998 by the European Society of Cardiology.
Acute and one year follow-up results after vessel size adapted PTCA using intracoronary ultrasound
Medical Clinic III, University of Tuebingen, Institute for Medical Information Processing, Tuebingen, Germany
accepted June 20, 1997
Aims
Recent randomized clinical trials have reported a reduction in restenosis with intracoronary stents and have suggested that this restenosis reduction is a result of the higher immediate luminal gain, in comparison to conventional percutaneous transluminal coronary angioplasty (PTCA). The hypothesis of this study is based on the assumption that PTCA results may be optimized by determining vessel dimensions before intervention, using intravascular ultrasound. This may lead to long-term PTCA results equivalent to PTCA and the additional placement of a stent. The purpose of this prospective non-randomized single-centre study was to evaluate (1) the safety and efficacy and (2) the long-term outcome of vessel-size adapted PTCA in patients with native coronary artery obstructions.
Methods and results
From January 1995 to December 1995 the morphological dimensions of target lesions were determined in 144 patients with 152 lesions by intravascular ultrasound prior to conventional balloon angioplasty. Quantitative assessment of the vascular dimensions were assessed on-line and the diameter of the balloon catheter was adapted to the external elastic membrane diameter at the lesion site. Using this strategy, mean balloon diameter was 4·0±0·5mm and mean pressure for complete balloon expansion was 7±2 atmospheres. Acute and one year follow-up results were obtained in all 144 patients. Acute events occurred in two patients (one death and one acute surgical revascularization). During one year follow-up, 16 patients (12%) had a clinical event including one cardiac death, two transmural myocardial infarctions, 10 repeat PTCAs within the target lesion and three elective coronary artery bypass grafts (CABG). In 75% (n:112) control angio-graphy was performed and revealed an angiographic restenosis rate of 21% using the NHLBI criteria of a diameter stenosis >50%.
Conclusion
Intravascular ultrasound provides an accurate and precise description of vascular dimensions at the site of the stenotic lesion. The use of balloon diameters following these measurements appears to be (1) safe in the acute setting with a low number of in hospital events and (2) gives a low restenosis rate and number of clinical events at one year follow-up. These promising results warrant verification in larger-scale randomized trials.
Key Words: Balloon angioplasty intravascular ultrasound restenosis
f1 Correspondence: Karl R. Karsch, MD, FESC, FACC, University of Tuebingen, Medical Clinic III, Otfried Muelerstr. 10, 72076 Tuebingen, Germany.
![]()
CiteULike
Connotea
Del.icio.us What's this?
This article has been cited by other articles:
![]() |
D. Chung and P. Krysiak Post-mediastinoscopy mortality due to drug-eluting stent thrombosis Eur. J. Cardiothorac. Surg., June 1, 2007; 31(6): 1149 - 1150. [Full Text] [PDF] |
||||
![]() |
F. Schiele, N. Meneveau, M. Gilard, J. Boschat, P. Commeau, L. P. Ming, P. Sewoke, M.-F. Seronde, M. Mercier, S. Gupta, et al. Intravascular Ultrasound-Guided Balloon Angioplasty Compared With Stent: Immediate and 6-Month Results of the Multicenter, Randomized Balloon Equivalent to Stent Study (BEST) Circulation, February 4, 2003; 107(4): 545 - 551. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. W. Serruys, B. de Bruyne, S. Carlier, J. E. Sousa, J. Piek, T. Muramatsu, C. Vrints, P. Probst, R. Seabra-Gomes, I. Simpson, et al. Randomized Comparison of Primary Stenting and Provisional Balloon Angioplasty Guided by Flow Velocity Measurement Circulation, December 12, 2000; 102(24): 2930 - 2937. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Di Mario, J. W. Moses, T. J. Anderson, R. Bonan, T. Muramatsu, A. C. Jain, J. Suarez de Lezo, S. Y. Cho, M. Kern, I. T. Meredith, et al. Randomized Comparison of Elective Stent Implantation and Coronary Balloon Angioplasty Guided by Online Quantitative Angiography and Intracoronary Doppler Circulation, December 12, 2000; 102(24): 2938 - 2944. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. W. Frey, J. M. Hodgson, C. Muller, H.-P. Bestehorn, and H. Roskamm Ultrasound-Guided Strategy for Provisional Stenting With Focal Balloon Combination Catheter : Results From the Randomized Strategy for Intracoronary Ultrasound-Guided PTCA and Stenting (SIPS) Trial Circulation, November 14, 2000; 102(20): 2497 - 2502. [Abstract] [Full Text] [PDF] |
||||
![]() |
P.W Serruys, J.N Hamburger, J Fajadet, M Haude, H Klues, R Seabra-Gomes, T Corcos, C Hamm, L Pizzuli, B Meier, et al. Total occlusion trial with angioplasty by using laser guidewire. The TOTAL trial Eur. Heart J., November 1, 2000; 21(21): 1797 - 1805. [Abstract] [PDF] |
||||
![]() |
W. J. Cantor, E. D. Peterson, J. J. Popma, J. P. Zidar, M. H. Sketch Jr., J. E. Tcheng, and E. M. Ohman Provisional stenting strategies: systematic overview and implications for clinical decision-making J. Am. Coll. Cardiol., October 1, 2000; 36(4): 1142 - 1151. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Schroeder, A. Baumbach, H. Mahrholdt, K.K. Haase, M. Oberhoff, C. Herdeg, A. Athanasiadis, and K.R. Karsch The impact of untreated coronary dissections on acute and long-term outcome after intravascular ultrasound guided PTCA Eur. Heart J., January 2, 2000; 21(2): 137 - 145. [Abstract] [PDF] |
||||
![]() |
R. A. M. van Liebergen, J. J. Piek, K. T. Koch, R. J. G. Peters, R. J. de Winter, C. E. Schotborgh, and K. I. Lie Hyperemic coronary flow after optimized intravascular ultrasound-guided balloon angioplasty and stent implantation J. Am. Coll. Cardiol., December 1, 1999; 34(7): 1899 - 1906. [Abstract] [Full Text] [PDF] |
||||
![]() |
K K HAASE, A BAUMBACH, and K R KARSCH Stents are used too often Heart, June 1, 1998; 79(6): 541 - 542. [Full Text] |
||||