Skip Navigation

European Heart Journal 1998 19(2):293-300; doi:10.1053/euhj.1997.0742
Copyright © 1998 by the European Society of Cardiology.
This Article
Right arrow FREE Full Text (PDF) Freely available
Right arrow E-letters: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (17)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Hansson, A.
Right arrow Articles by Olsson, S.B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hansson, A.
Right arrow Articles by Olsson, S.B.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Right atrial free wall conduction velocity and degree of anisotropy in patients with stable sinus rhythm studied during open heart surgery

A. Hanssonaf1, M. Holma, P. Blomströma, R. Johanssona, C. Lührsbf1, J. Brandtbf1 and S.B. Olssona

a Department of Cardiology, University Hospital, Lund, Sweden
b Department of Cardiothoracic Surgery, University Hospital, Lund, Sweden

accepted August 5, 1997

Aims

Although the perpetuation of several supraventricular arrhythmias is critically dependent upon intra-atrial conduction, the literature lacks detailed information on normal values of conduction velocity and degree of anisotropy. In order to explore these factors further, we have measured conduction velocities at the right atrial free wall during sinus rhythm and during atrial pacing in four directions parallel and perpendicular to the atrioventricular groove in patients with normal atria and stable sinus rhythm.

Methods and Results

Using a Bard Cardiac Mapping System, atrial ECGs were recorded using a 3x4cm electrode array with 56 equally spaced bipolar electrodes in 12 patients undergoing open heart surgery due to ischaemic heart disease or Wolff–Parkinson–White syndrome. A bipolar pen probe connected to a Medtronic 5328 stimulator was used for pacing at a 10% higher rate than sinus rhythm. The local activation times were manually set and isochronal activation maps were created for each recording. The conduction velocities were calculated from the activation maps over a distance ranging from 2·2 to 4·2cm.

The majority of the activation maps showed no signs of anisotropy; the others had less than 15% spatial inhomo-geneity of conduction. Mean conduction velocity, calculated from five consecutive beats, was 88±9cm.s–1(mean±SD), ranging between 68±4 and 103±3cm.s–1during sinus rhythm. Mean conduction velocity during atrial pacing was 81±16cm.s–1at a propagation direction of 0°, 74±14cm.s–1at a 90° direction, 79±12cm.s–1at 180° and 78±20cm.s–1at 270°, where 0° was parallel to the atrioventricular groove in the cranial direction and the angle increased counter-clockwise. Mean conduction velocity during sinus rhythm was significantly higher (P<0·05) than during atrial pacing at the 90° and 180° directions but not compared to atrial pacing at 0° or 270°. There was no significant difference in mean conduction velocity in different directions during atrial pacing.

Conclusion

Although anisotropy was documented during conduction velocity in individual cases, conduction velocity was not dependent on propagation direction at the epi-cardial right atrial free wall in patients with stable sinus rhythm. These findings do not exclude the presence of internodal preferential pathways as these are located subepicardially and a marked transmural discordance in activation has previously been documented in the vicinity of such pathways.

Key Words: Atrium, conduction velocity, anisotropy, epicardial.

f1 Correspondence: A Hansson, Department of Cardiology, University Hospital, S-221 85 Lund, Sweden.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Phil Trans R Soc AHome page
G. Seemann, C. Hoper, F. B Sachse, O. Dossel, A. V Holden, and H. Zhang
Heterogeneous three-dimensional anatomical and electrophysiological model of human atria
Phil Trans R Soc A, June 15, 2006; 364(1843): 1465 - 1481.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
A. M. Goodman, R. A. Oliver, C. S. Henriquez, and P. D. Wolf
A membrane model of electrically remodelled atrial myocardium derived from in vivo measurements
Europace, January 1, 2005; 7(s2): S135 - S145.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
P. Kanagaratnam, S. Rothery, P. Patel, N. J. Severs, and N. S. Peters
Relative expression of immunolocalized connexins 40 and 43 correlates with human atrial conduction properties
J. Am. Coll. Cardiol., January 2, 2002; 39(1): 116 - 123.
[Abstract] [Full Text] [PDF]


Home page
Circ. Res.Home page
David M. Harrild, Craig S. Henriquez ;
A Computer Model of Normal Conduction in the Human Atria
Circ. Res., September 29, 2000; 87 (7): e25 - e36.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
R. Becker, R. Klinkott, A. Bauer, J. C. Senges, K. D. Schreiner, F. Voss, W. Kuebler, and W. Schoels
Multisite pacing for prevention of atrial tachyarrhythmias: potential mechanisms
J. Am. Coll. Cardiol., June 1, 2000; 35(7): 1939 - 1946.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.