Skip Navigation

European Heart Journal 1999 20(2):140-147; doi:10.1053/euhj.1998.1151
Copyright © 1999 by the European Society of Cardiology.
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (4)
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Ionescu, A.A.
Right arrow Articles by Fraser, A.G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ionescu, A.A.
Right arrow Articles by Fraser, A.G.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Mobile echoes on prosthetic valves are not reproducible; results and clinical implications of a multicentre study

A.A. Ionescua,1, P. Moreno de la Santab, F.D. Dunstanc, E.G. Butchartb and A.G. Frasera

a Departmen of Cardiology, University of Wales College of Medicine, Cardiff, U.K.
b Department of Cardiac Surgery, University of Wales College of Medicine, Cardiff, U.K.
c Department of Medical Computing and Statistics, University of Wales College of Medicine, Cardiff, U.K.

accepted May 27, 1998

Abstract

Aims

To test the hypothesis that inter-observer variability accounts for the wide variation in reported prevalences of fibrin strands on prosthetic heart valves and to develop criteria for their identification and reporting.

Methods and Results

A videotape with 30 sequences of prosthetic heart valves imaged by transoesophageal echocardiography and showing abnormalities such as strands, microbubbles, and spontaneous echocardiographic contrast, was assessed in 13 European and three American centres. There were three duplicated examples, unbeknown to the observers. Definitions and reported prevalence rates of the abnormalities were analysed, and inter- and intra-observer agreement estimated with the kappa statistic.Mobile echoes were identified in 40 to 80% of the sequences on the tape. The reported prevalence of mobile echoes correlated with the time spent reporting the tape. There was moderate inter-observer agreement for the identification of any mobile echoes (kappa=0·38), but no agreement for their labelling (kappa=0·22), in spite of similar definitions. Intra-observer reproducibility was good (agreement in 76% of the reduplicated sequences).

Conclusions

The true prevalence and potential significance of mobile echoes on prosthetic heart valves cannot be assessed unless inter-observer consensus on echocardiographic criteria for identifying such echoes is reached.

Key Words: Heart valve prostheses • observer variation • echocardiography • transoesophageal

1 Correspondence: Dr Adrian Ionescu, Cardiology Department, University of Wales College of Medicine, Cardiff CF4 4XW, U.K.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
SEMIN CARDIOTHORAC VASC ANESTHHome page
R. B. A. Van den Brink
Evaluation of Prosthetic Heart Valves by Transesophageal Echocardiography: Problems, Pitfalls, and Timing of Echocardiography
Seminars in Cardiothoracic and Vascular Anesthesia, March 1, 2006; 10(1): 89 - 100.
[Abstract] [PDF]



Disclaimer:
Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.