Skip Navigation

European Heart Journal 1999 20(7):519-526; doi:10.1053/euhj.1998.1338
Copyright © 1999 by the European Society of Cardiology.
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (6)
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Langerveld, J.
Right arrow Articles by Jaarsma, W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Langerveld, J.
Right arrow Articles by Jaarsma, W.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Predictors of clinical events or restenosis during follow-up after percutaneous mitral balloon valvotomy

J. Langerveld, H.W. Thijs Plokker, S.M.P.G. Ernst, J.C. Kelder and W. Jaarsmaf1

Department of Cardiology, St. Antonius Hospital, Nieuwegein, The Netherlands

revised June 30, 1998; accepted September 30, 1998

Abstract

Aims The purpose of this study is to define predictors of events or restenosis during follow-up after percutaneous mitral balloon valvotomy.

Methods and Results Percutaneous mitral balloon valvotomy was attempted in 137 patients with severe mitral valve stenosis. In 127 patients follow-up was complete with a mean of 4·2±2·6 years. Events during follow-up were defined as death, mitral valve surgery or repeat percutaneous mitral balloon valvotomy. Restenosis was defined as a decrease in mitral valve area from ≥1·5cm2following percutaneous mitral balloon valvotomy to <1·5cm2.There was 80±4% event-free survival 4 years after percutaneous mitral balloon valvotomy. Multivariate analysis showed chronic atrial fibrillation at baseline (P=0·039, relative risk (RR)=2·5) and a high residual maximal gradient after percutaneous mitral balloon valvotomy (P=0·004, RR=2·0 per 5mmHg) to be independent predictors of an event during follow-up. The restenosis rate was 28·3% after 4 years. Chronic atrial fibrillation at baseline (P=0·0338, RR=2·2), a small mitral valve area after percutaneous mitral balloon valvotomy (P=0·0003, RR=0·8/0·1cm2) and a high residual maximal trans-mitral gradient (P=0·0252, RR=1·6/5mmHg) were all independent predictors of restenosis.

Conclusion Patients with chronic atrial fibrillation and a high maximal transmitral gradient after percutaneous mitral balloon valvotomy have a higher risk for events during follow-up. Restenosis is related to the presence of chronic atrial fibrillation at baseline and a suboptimal percutaneous mitral balloon valvotomy result.

Key Words: Mitral valve stenosis, valvuloplasty, echo-cardiography

f1 Correspondence : Dr Wybren Jaarsma, Department of Cardiololgy, St. Antonius Hospital, Koekoekslaan 1, 3435 CM Nieuwegein, The Netherlands.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
A. D. Zimmet, A. A. Almeida, R. W. Harper, J. J. Smolich, J. Goldstein, G. C. Shardey, and J. A. Smith
Predictors of surgery after percutaneous mitral valvuloplasty.
Ann. Thorac. Surg., September 1, 2006; 82(3): 828 - 833.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
J. Langerveld, N. M. van Hemel, J. C. Kelder, J. M. P. G. Ernst, H. W. M. Plokker, and W. Jaarsma
Long-term follow-up of cardiac rhythm after percutaneous mitral balloon valvotomy: Does atrial fibrillation persist?
Europace, January 1, 2003; 5(1): 47 - 53.
[Abstract] [PDF]



Disclaimer:
Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.