Skip Navigation

European Heart Journal 2000 21(13):1091-1098; doi:10.1053/euhj.1999.1857
Copyright © 2000 by the European Society of Cardiology.
This Article
Right arrow FREE Full Text (PDF) Freely available
Right arrow References
Right arrow E-letters: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (35)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Rambaldi, R
Right arrow Articles by Valkema, R
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Rambaldi, R
Right arrow Articles by Valkema, R
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Doppler tissue velocity sampling improves diagnostic accuracy during dobutamine stress echocardiography for the assessment of viable myocardium in patients with severe left ventricular dysfunction

R Rambaldia, D Poldermansa,f1, J.J Baxa, E Boersmaa, A Elhendya, W Vlettera, J.R.T.C Roelandta and R Valkemab

a Department of Cardiology, Erasmus Medical Center Rotterdam, Rotterdam, The Netherlands
b Department of Nuclear Medicine, Erasmus Medical Center Rotterdam, Rotterdam, The Netherlands

revised July 5, 1999; accepted July 22, 1999

Abstract

Background Both nuclear imaging with F18-fluorodeoxyglucose and dobutamine stress echocardiography have been used to identify viable myocardium, although dobutamine–stress echocardiography has been demonstrated to be the less sensitive of the two.

Aim To compare the accuracy of pulsed-wave Doppler tissue sampling with dobutamine–stress echocardiography for the detection of viable myocardium, using F18-fluorodeoxyglucose imaging as a reference.

Methods Forty patients with chronic coronary artery disease and left ventricular dysfunction (mean ejection fraction 33±11%), underwent F18-fluorodeoxyglucose imaging, dobutamine–stress echocardiography and pulsed-wave Doppler tissue sampling. Evaluation was performed using a six-segment model.

Results Visual assessment by resting echo was feasible in 230 out of 240 segments (96%); 177 (77%) segments showed severe dyssynergy at rest. F18-fluorodeoxyglucose imaging showed viability in 95 (54%) segments while 82 (46%) were non-viable. Ejection phase velocity at rest was not significantly different; ejection velocities during low-dose and peak-dose dobutamine, however, were significantly higher in viable myocardium (8·6±2·9 vs 6·0±1·8 and 9·3±31 vs 6·2±2·1cm.s–1). Using receiver operating characteristic curves the optimal cut-off value for viability assessment was an increase in the ejection phase velocity low-dose of 1±0·5cm.s–1, while 0±0·5cm.s–1predicted non-viability. The sensitivity and specificity (95%CI) of pulsed-wave Doppler tissue sampling and dobutamine–stress echocardiography for the prediction of viability was respectively 87% (82–92) vs 75% (67–81) (P<0·05) and 52% (44–59) vs 51% (45–59) (P=ns).

Conclusions The sensitivity of pulsed-wave Doppler tissue sampling is superior to dobutamine–stress echocardiography for the assessment of myocardial viability.

Key Words: Pulsed-wave Doppler tissue sampling, FDG-SPECT • dobutamine–stress echocardiography • myocardial viability

f1 Correspondence: Don Poldermans, MD, PhD, Thoraxcenter, Ba 300, Dr. Molewaterplein 40, 3015 GD Rotterdam, The Netherlands.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Br J AnaesthHome page
J. R. Larsen, P. Torp, K. Norrild, and E. Sloth
Propofol reduces tissue-Doppler markers of left ventricle function: a transthoracic echocardiographic study
Br. J. Anaesth., February 1, 2007; 98(2): 183 - 188.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
A. F L Schinkel, J. J Bax, and D. Poldermans
Clinical assessment of myocardial hibernation
Heart, January 1, 2005; 91(1): 111 - 117.
[Full Text] [PDF]


Home page
HeartHome page
M Bountioukos, A F L Schinkel, J J Bax, V Rizzello, R Valkema, B J Krenning, E Biagini, E C Vourvouri, J R T C Roelandt, and D Poldermans
Pulsed wave tissue Doppler imaging for the quantification of contractile reserve in stunned, hibernating, and scarred myocardium
Heart, May 1, 2004; 90(5): 506 - 510.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
P. C. Smits, R.-J. M. van Geuns, D. Poldermans, M. Bountioukos, E. E. M. Onderwater, C. H. Lee, A. P. W. M. Maat, and P. W. Serruys
Catheter-Based intramyocardial injection of autologous skeletal myoblasts as a primary treatment of ischemic heart failure: Clinical experience with Six-Month Follow-Up
J. Am. Coll. Cardiol., December 17, 2003; 42(12): 2063 - 2069.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
M Bountioukos, A F L Schinkel, J J Bax, V Rizzello, R Rambaldi, E C Vourvouri, J R T C Roelandt, and D Poldermans
Quantification of regional left ventricular function in Q wave and non-Q wave dysfunctional regions by tissue Doppler imaging in patients with ischaemic cardiomyopathy
Heart, November 1, 2003; 89(11): 1322 - 1326.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
D Pellerin, R Sharma, P Elliott, and C Veyrat
Tissue Doppler, strain, and strain rate echocardiography for the assessment of left and right systolic ventricular function
Heart, November 1, 2003; 89(90003): iii9 - 17.
[Abstract] [Full Text] [PDF]


Home page
Br J AnaesthHome page
K. Skarvan, M. Filipovic, J. Wang, W. Brett, and M. Seeberger
Use of myocardial tissue Doppler imaging for intraoperative monitoring of left ventricular function
Br. J. Anaesth., October 1, 2003; 91(4): 473 - 480.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
D. Poldermans and J. J Bax
Dobutamine echocardiography: a diagnostic tool comes of age
Eur. Heart J., September 1, 2003; 24(17): 1541 - 1542.
[Full Text] [PDF]


Home page
Eur Heart JHome page
R. Hoffmann, T.H. Marwick, D. Poldermans, H. Lethen, R. Ciani, P. van der Meer, H.-P. Tries, P. Gianfagna, P. Fioretti, J.J. Bax, et al.
Refinements in stress echocardiographic techniques improve inter-institutional agreement in interpretation of dobutamine stress echocardiograms
Eur. Heart J., May 2, 2002; 23(10): 821 - 829.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
R. Hoffmann, E. Altiok, B. Nowak, N. Heussen, H. Kuhl, H.-J.u. Kaiser, U. Bull, and P. Hanrath
Strain rate measurement by doppler echocardiography allows improvedassessment of myocardial viability inpatients with depressed left ventricular function
J. Am. Coll. Cardiol., February 6, 2002; 39(3): 443 - 449.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
F.J. Pinto
Myocardial viability: the search for a perfect method is not over yet
Eur. Heart J., July 1, 2000; 21(13): 1039 - 1040.
[PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.