Skip Navigation

European Heart Journal 2000 21(8):687-696; doi:10.1053/euhj.1999.2102
Copyright © 2000 by the European Society of Cardiology.
This Article
Right arrow FREE Full Text (PDF) Freely available
Right arrow References
Right arrow E-letters: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (5)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Brennecke, R
Right arrow Articles by Nissen, S.E
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Brennecke, R
Right arrow Articles by Nissen, S.E
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

American College of Cardiology/ European Society of Cardiology international study of angiographic data compression phase III. Measurement of image quality differences at varying levels of data compression

R Brenneckea,f1, U Bürgela, R Simonb, G Rippinc, H.P Fritscha, T Beckerb and S.E Nissend

a II Medical Clinic, Johannes-Gutenberg-University, Mainz, Germany
b Medical Clinic, Albrechts University, Kiel, Germany
c Department of Medical Statistics, Johannes-Gutenberg-University, Mainz, Germany
d Cleveland Clinic Foundation, Cleveland, Ohio

revised June 1, 1999; accepted December 1, 1999

Abstract

Objectives We sought to investigate up to which level of Joint Photographic Experts Group (JPEG) data compression the perceived image quality and the detection of diagnostic features remain equivalent to the quality and detectability found in uncompressed coronary angiograms.

Background Digital coronary angiograms represent an enormous amount of data and therefore require costly computerized communication and archiving systems. Earlier studies on the viability of medical image compression were not fully conclusive.

Methods Twenty-one raters evaluated sets of 91 cine runs. Uncompressed and compressed versions of the images were presented side by side on one monitor, and image quality differences were assessed on a scale featuring six scores. In addition, the raters had to detect pre-defined clinical features. Compression ratios (CR) were 6:1, 10:1 and 16:1. Statistical evaluation was based on descriptive statistics and on the equivalence t -test.

Results At the lowest CR (CR 6:1), there was already a small (15%) increase in assigning the aesthetic quality score indicating "quality difference is barely discernible—the images are equivalent.’ At CR 10:1 and CR 16:1, close to 10% and 55%, respectively, of the compressed images were rated to be "clearly degraded, but still adequate for clinical use’ or worse. Concerning diagnostic features, at CR 10:1 and CR 16:1 the error rate was 9·6% and 13·1%, respectively, compared with 9% for the baseline error rate in uncompressed images.

Conclusions Compression at CR 6:1 provides equivalence with the original cine runs. If CR 16:1 were used, one would have to tolerate a significant increase in the diagnostic error rate over the baseline error rate. At CR 10:1, intermediate results were obtained.

f1 Correspondence: Dr. Rüdiger Brennecke, II Medical Clinic, Johannes-Gutenberg-University Hospital, D55131 Mainz, Germany, E-mail: incis.rb@uni-mainz.de


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Radiat Prot DosimetryHome page
G. Bernardi, R. Padovani, L. Spedicato, W. Desmet, M. R. Malisan, J. D. Giannuleas, E. Neofotistou, A. Manginas, Z. Olivari, J. Cosgrave, et al.
Image quality criteria in cardiology
Radiat Prot Dosimetry, December 1, 2005; 117(1-3): 102 - 106.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
R.F. Bonvini, L. Caoduro, A. Menafoglio, L. Calanca, L. von Segesser, and A. Gallino
Telemedicine for cardiac surgery candidates
Eur. J. Cardiothorac. Surg., September 1, 2002; 22(3): 377 - 380.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
S.E. Nissen, J.W. Hirshfeld, and R. Simon
The international angiographic compression study
Eur. Heart J., April 2, 2000; 21(8): 601 - 603.
[PDF]


Home page
Eur Heart JHome page
J.C Tuinenburg, G Koning, E Hekking, A.H Zwinderman, T Becker, R Simon, and J.H.C Reiber
American College of Cardiology/ European Society of Cardiology international study of angiographic data compression phase II. The effects of varying JPEG data compression levels on the quantitative assessment of the degree of stenosis in digital coronary angiography
Eur. Heart J., April 2, 2000; 21(8): 679 - 686.
[Abstract] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.