Skip Navigation

European Heart Journal 2001 22(19):1808-1816; doi:10.1053/euhj.2001.2608
Copyright © 2001 by the European Society of Cardiology.
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (25)
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Wöhrle, J
Right arrow Articles by Höher, M
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wöhrle, J
Right arrow Articles by Höher, M
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Comparison of the heparin coated vs the uncoated Jostent®—no influence on restenosis or clinical outcome

J Wöhrlef1, E Al-Khayer, U Grötzinger, C Schindler, M Kochs, V Hombach and M Höher

Department of Cardiology, University of Ulm, Ulm, Germany

revised January 16, 2001; accepted January 17, 2001

Abstract

Aims Heparin coating of stents is thought to reduce stent thrombosis and restenosis rates. However, clinical data comparing coated and uncoated stents of the same model are lacking. We compared the heparin coated (C) and the uncoated (U) version of the Jostent®stent with regard to the clinical and angiographic outcome after 6 months.

Methods and Results Provisional stenting was done in 277 patients and 306 lesions; only 40 were Benestent-II like lesions. Delivery success rate was 98·4%. Both groups (C/U: n=156/150 lesions) were comparable in clinical and procedural data. Post stenting, reference diameter (C/U: 2·68±0·56/2·66±0·53mm) and minimal lumen diameter did not differ (C/U: 2·48±0·47/2·48±0·52mm). During follow-up the rate of subacute stent thrombosis (C/U: 1·9%/1·3%) and myocardial infarction did not differ. Angiography at the 6-month follow-up (79·4%) revealed no difference in restenosis rate (C/U: 33·1%/30·3%). Risk factors for restenosis were a type B2/C lesion (P<0·02), a stented segment longer than 16mm (P<0·006) and a stent inflation pressure <14 bar (P<0·0063).

Conclusion Corline heparin coating of the Jostent®has no impact on the in-hospital complication rate, stent thrombosis or restenosis. The Jostent®design gives a high procedural success rate and satisfying result at 6 months in an everyday patient population undergoing provisional stenting.

Key Words: Stent, restenosis, heparin coating, thrombosis

f1 Correspondence: Martin Höher, MD, FESC, University of Ulm, Department of Cardiology, Robert-Koch-Straße 8, 89081 Ulm, Germany.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
HeartHome page
R Lowe, I B A Menown, G Nogareda, and I M Penn
Coronary stents: in these days of climate change should all stents wear coats?
Heart, June 1, 2005; 91(suppl_3): iii20 - iii23.
[Full Text] [PDF]


Home page
RadiologyHome page
K. Schurmann, J. Lahann, P. Niggemann, B. Klosterhalfen, J. Meyer, A. Kulisch, D. Klee, R. W. Gunther, and D. Vorwerk
Biologic Response to Polymer-coated Stents: In Vitro Analysis and Results in an Iliac Artery Sheep Model
Radiology, January 1, 2004; 230(1): 151 - 162.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
S. H. Wilson, P. Fasseas, J. L. Orford, R. J. Lennon, T. Horlocker, N. E. Charnoff, S. Melby, and P. B. Berger
Clinical outcome of patients undergoing non-cardiac surgery in the two months following coronary stenting
J. Am. Coll. Cardiol., July 16, 2003; 42(2): 234 - 240.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
M. Hoher, J. Wohrle, M. Wohlfrom, J. Kamenz, T. Nusser, O. C. Grebe, H. Hanke, M. Kochs, S. N. Reske, V. Hombach, et al.
Intracoronary {beta}-Irradiation With a Rhenium-188-Filled Balloon Catheter: A Randomized Trial in Patients With De Novo and Restenotic Lesions
Circulation, June 24, 2003; 107(24): 3022 - 3027.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
M. Haude, T. F.M. Konorza, U. Kalnins, A. Erglis, K. Saunamaki, H. D. Glogar, E. Grube, R. Gil, A. Serra, H. G. Richardt, et al.
Heparin-Coated Stent Placement for the Treatment of Stenoses in Small Coronary Arteries of Symptomatic Patients
Circulation, March 11, 2003; 107(9): 1265 - 1270.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
M. N. Babapulle and M. J. Eisenberg
Coated Stents for the Prevention of Restenosis: Part II
Circulation, November 26, 2002; 106(22): 2859 - 2866.
[Full Text] [PDF]


Home page
J Am Coll CardiolHome page
A. Kastrati, H. Schuhlen, and A. Schomig
Stenting for small coronary vessels: a contestable winner
J. Am. Coll. Cardiol., November 15, 2001; 38(6): 1604 - 1607.
[Full Text] [PDF]


Home page
Eur Heart JHome page
P.J. de Feyter
The quest for the ideal stent
Eur. Heart J., October 1, 2001; 22(19): 1766 - 1768.
[PDF]



Disclaimer:
Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.