Skip Navigation

European Heart Journal 2001 22(24):2275-2283; doi:10.1053/euhj.2001.2693
Copyright © 2001 by the European Society of Cardiology.
This Article
Right arrow FREE Full Text (PDF) Freely available
Right arrow References
Right arrow E-letters: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (19)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Clark, A.L.
Right arrow Articles by Anker, S.D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Clark, A.L.
Right arrow Articles by Anker, S.D.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Ventricular assist device in severe heart failure. Effects on cytokines, complement and body weight

A.L. Clarka,f1, M. Loebeb, E.V. Potapovb, K. Egererc, C. Knosallab, R. Hetzerb and S.D. Ankerc,d

a Department of Academic Cardiology, Castle Hill Hospital, Cottingham, Hull, U.K.
b Department of Thoracic and Cardiovascular Surgery, Deutsches Herzzentrum Berlin, Berlin, Germany
c Franz-Volhard-Klinik (Charité, Berlin-Buch) at MDC Berlin, Germany
d Department of Cardiac Medicine, National Heart and Lung Institute, London, U.K.

revised March 6, 2001; accepted March 14, 2001

Abstract

Aims Inflammatory and immune activation and body wasting are important features of end-stage chronic heart failure. It is not known whether restoration of cardiac output by assist device implantation can improve these abnormalities.

Methods We studied 48 patients (39 males; age 45±2 years) with NYHA class IV heart failure. All patients underwent ventricular assist device implantation for end-stage heart failure as a bridge to cardiac transplantation. Plasma levels of tumour necrosis factor {alpha}, and its receptors, interleukin-6, elastase, activated complement, and soluble CD14 receptors were measured at the time of operation and in survivors at 1 week (n=46), 40 days (n=35) and 90 days (n=26). Follow-up was for a minimum of 1 year.

Results One-year survival was 35% (95% CI: 22–49%). Body mass index was the only predictor of survival (body mass index >25 (n=16); survival 63 (39–86)%; body mass index <25 (n=32); survival 22 (7·5–36)%: P=0·003). Tumour necrosis factor {alpha} fell from 9·66±1·33pg.ml–1to 4·2±1·0 at 1 week (P=0·008), but returned to pre-operative levels at 90 days. Interleukin-6, activated complement and elastase fell progressively to 40 days, but were rising at 90 days. There was no change in tumour necrosis factor receptor. There was a gradual rise in CD14 (3·99±0·15µg.ml–1at baseline, 5·02±0·39 at 90 days, P=0·006). After surgery, body weight fell from 80±2 to 73±2kg by 1 month (P<0·001) and to 72±2kg at 90 days.

Conclusions Ventricular assist device implantation results in a short-term fall in tumour necrosis factor {alpha} and interleukin-6, but no change in CD14 or tumour necrosis factor receptor, suggesting that the pathophysiological process resulting in inflammation was not altered by left ventricular assist device implantation. Low body mass index is related to poor outcome after assist device implantation, and no weight gain.

Key Words: Chronic heart failure, ventricular assist device, cytokines, tumour necrosis factor {alpha}

f1 Correspondence: Dr A. L. Clark, Department of Academic Cardiology, Castle Hill Hospital, Castle Road, Cottingham, Hull, HU16 5JQ, U.K.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Eur J Heart FailHome page
B. Vrtovec, R. Radovancevic, R. M. Delgado, B. Radovancevic, A. W. Bracey, I. D. Gregoric, and O.H. Frazier
Significance of anaemia in patients with advanced heart failure receiving long-term mechanical circulatory support
Eur J Heart Fail, October 1, 2009; 11(10): 1000 - 1004.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
M. Musci, A. Loforte, E. V. Potapov, T. Krabatsch, Y. Weng, M. Pasic, and R. Hetzer
Body Mass Index and Outcome After Ventricular Assist Device Placement
Ann. Thorac. Surg., October 1, 2008; 86(4): 1236 - 1242.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
P. M. Kimball, M. Flattery, F. McDougan, and V. Kasirajan
Cellular Immunity Impaired Among Patients on Left Ventricular Assist Device for 6 Months
Ann. Thorac. Surg., May 1, 2008; 85(5): 1656 - 1661.
[Abstract] [Full Text] [PDF]


Home page
Eur J Heart FailHome page
A. L. Clark, C. Knosalla, E. Birks, M. Loebe, C. H. Davos, S. Tsang, A. Negassa, M. Yacoub, R. Hetzer, A. J.S. Coats, et al.
Heart transplantation in heart failure: The prognostic importance of body mass index at time of surgery and subsequent weight changes
Eur J Heart Fail, August 1, 2007; 9(8): 839 - 844.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
M Vanderheyden, W J Paulus, M Voss, P Knuefermann, N Sivasubramanian, D Mann, and G Baumgarten
Myocardial cytokine gene expression is higher in aortic stenosis than in idiopathic dilated cardiomyopathy
Heart, July 1, 2005; 91(7): 926 - 931.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
F. Langer, R. Schramm, M. Bauer, D. Tscholl, T. Kunihara, and H.-J. Schafers
Cytokine Response to Pulmonary Thromboendarterectomy
Chest, July 1, 2004; 126(1): 135 - 141.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
J. G. F. Cleland and A. L. Clark
Delivering the cumulative benefits of triple therapy to improve outcomes in heart failure: Too many cooks will spoil the broth
J. Am. Coll. Cardiol., October 1, 2003; 42(7): 1234 - 1237.
[Full Text] [PDF]


Home page
Physiol. GenomicsHome page
Y. Chen, S. Park, Y. Li, E. Missov, M. Hou, X. Han, J. L. Hall, L. W. Miller, and R. J. Bache
Alterations of gene expression in failing myocardium following left ventricular assist device support
Physiol Genomics, August 15, 2003; 14(3): 251 - 260.
[Abstract] [Full Text] [PDF]


Home page
ICVTSHome page
S. Beholz, H. Hotz, J. Grosse, and W. Konertz
Biventricular assist device in extreme anorexia nervosa
Interactive CardioVascular and Thoracic Surgery, September 1, 2002; 1(1): 35 - 37.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
K. Chatterjee
Refractory heart failure--drugs and devices
Eur. Heart J., December 2, 2001; 22(24): 2227 - 2230.
[PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.