Skip Navigation


European Heart Journal Advance Access originally published online on July 8, 2005
European Heart Journal 2005 26(20):2127-2135; doi:10.1093/eurheartj/ehi387
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow HTML Page - index.htslp
Right arrow Figure 2
Right arrow Figure 2 Supplement
Right arrow Figure 3 Supplement
Right arrow All Versions of this Article:
26/20/2127    most recent
ehi387v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (4)
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Mahrholdt, H.
Right arrow Articles by Sechtem, U.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Mahrholdt, H.
Right arrow Articles by Sechtem, U.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The European Society of Cardiology 2005. All rights reserved. For Permissions, please e-mail: journals.permissions@oxfordjournals.org

Left ventricular wall motion abnormalities as well as reduced wall thickness can cause false positive results of routine SPECT perfusion imaging for detection of myocardial infarction

Heiko Mahrholdt1,*, Andreji Zhydkov1, Stefan Hager1, Gabriel Meinhardt1, Holger Vogelsberg1, Anja Wagner2 and Udo Sechtem1

1Division of Cardiology, Robert-Bosch-Krankenhaus, Auerbachstrasse 110, 70376 Stuttgart, Germany
2Duke Cardiovascular MR Center, Durham, NC, USA

Received 21 October 2004; revised 3 May 2005; accepted 2 June 2005; online publish-ahead-of-print 8 July 2005.

* Corresponding author. Tel: +49 711 8101 3456; fax:+49 711 8101 3795. E-mail address: heiko.mahrholdt{at}rbk.de

Aims The relationship between wall thickness, wall thickening, wall motion, and single-photon emission computed tomography (SPECT) results for detection of myocardial infarction has never been systematically evaluated in a clinical setting. In particular, the discussion whether non-ischaemic regional wall motion abnormalities and reduced wall thickness can cause SPECT to be false positive for infarct detection remains unsettled.

Methods and results We therefore evaluated patients presenting with left bundle branch block (LBBB) and only included them in the analysis if any coronary artery disease (CAD) had been ruled out by angiography. LBBB is known to cause septal wall motion abnormalities as well as to reduce systolic septal wall thickness. Thus, LBBB is a good non-ischaemic clinical model to evaluate the influence of wall thickness and wall motion on the homogeneity of tracer distribution in resting SPECT images. SPECT revealed fixed defects in all 139 patients initially identified for possible enrolment. CAD was found to be present by angiography in 120 patients. The remaining 19 patients without any CAD underwent cardiovascular magnetic resonance (CMR) and were included in the study. Evaluation of SPECT using a 72-segment model revealed septum-related fixed defects in all 19 patients. Every defect was interpreted as myocardial infarction by blinded observers. The comparison of nuclear results to the gold standard CMR demonstrated that none of the fixed SPECT defects did represent myocardial infarcts. Defects, however, exactly matched areas of wall motion abnormalities as well as regions with impaired wall thickness as demonstrated by CMR. On a segmental basis, we found a strong relationship between wall motion and reduced wall thickness on one hand and SPECT defects on the other hand. For example, only 5% of segments with normal wall motion were false positive by SPECT for myocardial infarction, whereas 93% of all dyskinetic segments were found to be false positive (P<0.01). Comparing wall thickness to SPECT results revealed that 58% of segment in which wall thickness was 1 SD below the mean and 93% of segments in which wall thickness was 2 SD below the mean showed fixed defects by SPECT. Conversely, only 0.5% of segments in which wall thickness was above the mean were affected by false positive SPECT results (P<0.01).

Conclusion Wall motion abnormalities as well as impaired myocardial wall thickening and wall thickness can cause false positive results of resting SPECT myocardial perfusion imaging for detection of myocardial infarction in the absence of myocardial infarct scars and CAD.

Key Words: Myocardial infarction • Magnetic resonance imaging • Left bundle branch block • Single-photon emission computed tomography


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer:
Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.