Skip Navigation

European Heart Journal 1984 5(11):948-953;
Copyright © 1984 by the European Society of Cardiology.
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by JENNI, R.
Right arrow Articles by ANLIKER, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by JENNI, R.
Right arrow Articles by ANLIKER, M.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© 1984 The European Society of Cardiology

A comparison between single gate and multigate ultrasonic Doppler measurements for the assessment of the velocity pattern in the human ascending aorta

R. JENNI, A. VIELI, K. RUFFMANN, H.-P. KRAYENBUEHL and M. ANLIKER

Medical Policlinic, Cardiology and Institute for Biomedical Engineering, University of Zurich and Swiss Federal Institute of Technology Zurich, Switzerland

Received 23 May 1984; revised 24 August 1984; .

Address for Correspondence: Rolf Jenni, M.D., M.S.E.E., Medical Policlinic, Cardiology, University Hospital, Raemistrasse 100, CH-8091 Zurich, Switzerland

Abstract

The velocity pattern in the ascending aorta of 15 healthy adults was measured quasisimultaneously from the Doppler-shifts produced in 16 gates distributed equally within the cross-section along a narrow ultrasound beam which centrally traversed the vessel upstream of the brachiocephalic trunk. A comparison between the time integrals of the velocities in gates 9 (centre line), 4 and 13 (off centre) and the time integral of the weighted mean of the velocities of all gates correlated with r=0.90, SEE=1.05 (gate 9), r=0.90, SEE 0.88 (gate 4) and r=0.92, SEE 0.94 (gate 13). A better correlation (r=0.96, SEE=0.60) was found between the linear mean of all gates and the weighted mean.

These results show that Doppler measurements in single small gates are not appropriate to determine the average cross-sectional blood flow velocity in healthy adults.

Key Words: Velocity pattern in the human ascending aorta • multigate Doppler


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer:
Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.