Skip Navigation

European Heart Journal 1988 9(4):388-394;
Copyright © 1988 by the European Society of Cardiology.
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by VAN OORT, A.
Right arrow Articles by DANIELS, O.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by VAN OORT, A.
Right arrow Articles by DANIELS, O.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© 1988 The European Society of Cardiology

Reference values for pulsed Doppler signals from the blood flow velocity on both sides of the pulmonary valve

A. VAN OORT, S. DE KNECHT, I. VAN DAM, A. HERINGA, T. DE BOO, J. ALSTERS, J. HOPMAN, J. FAST, T. VAN DER WERF and O. DANIELS

Interuniversity Cardiology Institute, and Radboud University Hospital Nijmegen, The Netherlands

Received 4 September 1987; .

Address for correspondence: Anton van Oort, M.D., Department of Pediatric Cardiology, University Hospital, Nijmegen. P.O. Box 9101, 6500 HB Nijmegen, The Netherlands.

Abstract

Pulsed Doppler signals were recorded from the pulmonary artery and the right ventricular outflow tract in 215 healthy subjects (120 males, 95 females; 1–65 years). Amplitude spectra from these Doppler signals were stored in digital form together with adjustment data for the instrument and the simultaneously recorded ECG. From these Doppler spectra the median of the maximal velocity ( Vmax), the maximal acceleration (Amax) and the dispersion of the velocity distribution around Vmax (width) were calculated. These three median values were used to characterize the Doppler spectra and to define normal values for bloodflow velocities. Thus, calculations were made without observer interaction using a well-defined computer program. The effect of age, gender, body surface area and heart rate were studied. Reference ranges were calculated.

There is a slight decrease of the median value of Vmax and Amax in the pulmonary artery during lifetime from 80 to 70 cm s–1 and from 1200 to 800 cms–2, respectively. On the other hand, there is no correlation between age and Vmax and Amax in the right ventricular outflow tract. The width of the spectra increases with age at both sites. No significant changes with age were seen with the other variables.

Key Words: healthy subjects • right ventricular outflow tract • main pulmonary artery


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Eur J EchocardiogrHome page
P. Ballo, A. Bocelli, A. Motto, and S. Mondillo
Concordance between M-mode, pulsed Tissue Doppler, and colour Tissue Doppler in the assessment of mitral annulus systolic excursion in normal subjects
Eur J Echocardiogr, April 2, 2008; (2008) jen130v1.
[Abstract] [Full Text] [PDF]


Home page
Cardiovasc ResHome page
E. Sloth, E. M. Pedersen, H. Egeblad, J.M. Hasenkam, and B. Juhl
Transesophageal multiplane imaging of the human pulmonary artery: a comparison of MRI and multiplane transesophageal two-dimensional echocardiography
Cardiovasc Res, June 1, 1997; 34(3): 582 - 589.
[Abstract] [Full Text] [PDF]



Disclaimer:
Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.