Skip Navigation

European Heart Journal 1988 9(8):866-873;
Copyright © 1988 by the European Society of Cardiology.
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by RIBEIRO, P. A.
Right arrow Articles by KASAB, S. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by RIBEIRO, P. A.
Right arrow Articles by KASAB, S. A.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© 1988 The European Society of Cardiology

Percutaneous single- and double-balloon aortic valvotomy in adolescents and young adults with congenital aortic stenosis

P. A. RIBEIRO, M. AL ZAIBAG, M. HALIM and S. AL KASAB

Cardiac Department Armed Forces Hospital Riyadh, Kingdom of Saudi Arabia

Received 17 September 1987; revised 2 February 1988; .

Address for reprints: Dr P. A. Ribeiro, E239, Armed Forces Hospital, P.O. Box 7897, Riyadh 11159, Kingdom of Saudi Arabia.

Abstract

Percutaneous balloon aortic valvotomy was attempted in six consecutive adolescents and young adults, (meanage 18 ± 5 years), with severe congenital aortic valvular stenosis. Peak systolic aortic valve gradient measurement and aortography was performed before and immediately after valvotomy, and a 1–6 months follow-up. The single-balloon technique was used in two patients and the double-balloon technique in four patients. After balloon valvotomy the mean peak systolic aortic valve gradient (PSG) decreased from 122 ± 53 to 43 ± 20 mmHg (P > 001). The haemodynamic improvement persisted at follow-up (PSG = 47 ±31 mmHg), except in one patient who had previously undergone aortic surgical valvotomy. One balloon valvotomy was unsuccessful, presumably because of the selection of an inappropriately small balloon. Two patients with critical aortic stenosis (PSG>165 mmHg), who exhibited a thick aortic valve on echocardiography with a relatively small aortic root and annulus, had a dramatic reduction in PSG. However, the degree of aortic regurgitation increased significantly in both cases. The theoretical haemodynamic advantage of the double versus the single balloon techniques was confirmed in one patient. We have demonstrated that percutaneous balloon aortic valvotomy using either the single- or double-balloon technique is feasible in young adults with severe congenital aortic stenosis. Further studies are required both to define appropriate patients and the selection of balloon diameter and length.

Key Words: balloon valvotomy • aortic stenosis.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
ANGIOLOGYHome page
Y. Chandra Shekhar and I. S. Anand
Balloon Dilation of Postoperative Persistent Coarctation of Aorta and Valvular Aortic Stenosis A Case Report
Angiology, July 1, 1992; 43(7): 614 - 617.
[Abstract] [PDF]



Disclaimer:
Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.