Skip Navigation


European Heart Journal Advance Access originally published online on April 13, 2006
European Heart Journal 2006 27(12):1459-1464; doi:10.1093/eurheartj/ehi883
This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
27/12/1459    most recent
ehi883v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Related articles in EHJ
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (5)
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Paetsch, I.
Right arrow Articles by Nagel, E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Paetsch, I.
Right arrow Articles by Nagel, E.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The European Society of Cardiology 2006. All rights reserved. For Permissions, please e-mail: journals.permissions@oxfordjournals.org

Determination of interobserver variability for identifying inducible left ventricular wall motion abnormalities during dobutamine stress magnetic resonance imaging

Ingo Paetsch1,*, Cosima Jahnke1, Victor A. Ferrari2, Frank E. Rademakers3, Patricia A. Pellikka4, W. Gregory Hundley5,6, Don Poldermans7, Jeroen J. Bax8, Karl Wegscheider9, Eckart Fleck1 and Eike Nagel1

1 Department of Cardiology, German Heart Institute Berlin, Augustenburger Platz 1, 13353 Berlin, Germany
2 Department of Medicine, Cardiovascular Medicine Division, University of Pennsylvania Medical School, Pennsylvania, PA, USA
3 Department of Cardiology, Gasthuisberg University Hospital, Leuven, Belgium
4 Division of Cardiovascular Diseases, Mayo Clinic, Rochester, Minnesota, MN, USA
5 Department of Internal Medicine/Cardiology Section, Wake Forest University School of Medicine, Winston-Salem, North Carolina, NC, USA
6 Department of Radiology, Wake Forest University School of Medicine, Winston-Salem, North Carolina, NC, USA
7 Department of Cardiology, Thorax Center Rotterdam, The Netherlands
8 Department of Cardiology, Leiden University Medical Center, The Netherlands
9 Institute for Statistics and Econometry, University of Hamburg, Hamburg, Germany

Received 17 October 2005; revised 28 February 2006; accepted 23 March 2006; online publish-ahead-of-print 13 April 2006.

* Corresponding author. Tel: +49 30 4593 2457; fax: +49 30 4593 2458. E-mail address: paetsch{at}dhzb.de

See page 1394 for the editorial comment on this article (doi:10.1093/eurheartj/ehl047)


    Abstract
 Top
 Abstract
 Introduction
 Methods
 Results
 Discussion
 Conclusions
 Acknowledgements
 References
 
Aims To determine the interobserver variability for identifying inducible left ventricular (LV) wall motion abnormalities during high-dose dobutamine/atropine stress cardiovascular magnetic resonance (DSMR).

Methods and results Four readers from various institutions were supplied with the image data from 150 consecutive DSMR examinations and asked to grade wall motion and image quality throughout graded doses of dobutamine infusion administered to achieve 85% of the maximum age-predicted heart rate. Inducible ischaemia was identified if more than one segment demonstrated a new or worsening LV wall motion abnormality, and significant stenosis was defined as ≥50% luminal diameter reduction by quantitative contrast coronary angiography. Seventy-seven patients (51%) had luminal narrowings ≥50%. Diagnostic performance (sensitivity, specificity, diagnostic accuracy) of all readers was 78.2, 87.0 and 82.5%. Disagreement between two readers occurred in every seventh examination. Agreement on the presence or absence of inducible wall motion abnormalities was moderate (mean kappa value 0.59, range 0.52–0.76). Diagnostic performance and disagreement were independent of the presence of luminal narrowings ≥50% or the number of diseased coronary vessels. Image quality was regarded excellent in 89.3% of standard views.

Conclusion In the setting of multiple observers from different institutions performing a diagnostic reading of DSMR examinations carried out at a single centre, the interobserver variability was low for identifying inducible LV wall motion abnormalities indicative of coronary arterial luminal narrowings ≥50%.

Key Words: Cardiac magnetic resonance imaging • Dobutamine stress • Wall motion analysis • Reader variability


    Introduction
 Top
 Abstract
 Introduction
 Methods
 Results
 Discussion
 Conclusions
 Acknowledgements
 References
 
Cardiovascular magnetic resonance (CMR) has gained widespread acceptance for assessment of global and regional left ventricular (LV) function at rest and exhibits low inter- and intraobserver variability for the assessment of LV volumes and regional wall motion.1 Recently, CMR has been implemented during pharmacological stress [dobutamine stress magnetic resonance (DSMR)] for the detection of inducible wall motion abnormalities due to flow-limiting coronary arterial luminal narrowings. Clinically, DSMR has proven to be safe, feasible, accurate, and reliable for identifying myocardial ischaemia and has been used successfully in limited patient populations to determine cardiac prognosis.27

Importantly, however, the interobserver variability for identifying inducible LV wall motion abnormalities during ischaemia has not been established. This issue is important because a low interobserver variability would allow application of a standardized DSMR test in serial patient studies. In particular, if DSMR were to be utilized in multicentre trials, unanimous reader decisions regarding the presence of inducible wall motion abnormalitites would increase the consistency of the data.

Accordingly, we assessed the interobserver variability of DSMR among four readers from various institutions. We excluded any information on patient history or stress testing.


    Methods
 Top
 Abstract
 Introduction
 Methods
 Results
 Discussion
 Conclusions
 Acknowledgements
 References
 
Study population
The study was conducted in accordance with the standards of the Charité and Virchow-Klinikum Ethics Committee. Between January 2002 and July 2003, a total number of 162 consecutive patients with chest pain referred to the German Heart Institute for clinically indicated cardiac catheterization were screened for study inclusion and 150 patients willingly agreed to give written informed consent for prior DSMR testing. Patients were eligible if they had suspected or known coronary artery disease (CAD) (with or without prior percutaneous revascularization or a history of previous myocardial infarction). Patients with prior coronary surgery or typical contraindications for MR imaging and administration of dobutamine were not considered. All study participants were instructed to refrain from ß-blockers and antianginal medication at least 24 h prior to the CMR study.

Magnetic resonance study
CMR was performed with the patient in the supine position using a 1.5 T MR scanner (Philips Intera CV, Best, The Netherlands) equipped with a PowerTrak6000 gradient system (23 mT/m; 219 µs rise time), a five-element phased array coil and software package release 9. Cardiac synchronization was performed using four electrodes placed on the left anterior hemithorax (Vector-ECG).

Magnetic resonance imaging technique
For cine imaging, a steady-state free precession sequence was used during an end-expiratory breathhold of 4–6 s in combination with parallel image acquisition (SENSE) and retrospective gating (25 phases/cardiac cycle, repetition time 2.7 ms, echo time 1.4 ms, flip angle 60°). Typical in plane spatial resolution was 1.8x1.8 mm2 with a slice thickness of 8 mm.

Scan procedure
The following standardized scheme for image planning was rigorously applied by the technician performing the scan procedure: (i) rapid multislice survey, (ii) expiratory, single-angulated, single-slice cine scan intersecting the apex and the coaptation point of the mitral valve on a transverse view, (iii) expiratory, double-angulated long-axis cine scan intersecting the apex and the coaptation point of the mitral valve planned on the previously acquired single-angulated view, (iv) expiratory cine imaging of three short-axis views acquired at 25, 50, and 75% of the distance between the epicardial border of the LV apex and the coaptation of the mitral valve (end-systolic phase), (v) expiratory cine imaging of four-, five-chamber views planned on the equatorial short-axis orientation.

Dobutamine stress MR protocol
The pharmacological stress protocol followed the previously described high-dose dobutamine/atropine regimen.4 Briefly, after acquisition of rest cine scans in the diagnostic standard views (apical-, mid-, and basal short-axis views, four-, two-, and three-chamber views), dobutamine was infused intravenously at 3 min stages at doses of 10, 20, 30, and 40 µg/kg/min and all standard views were acquired at each level. If target heart rate, defined as age-predicted submaximal heart rate [(220–age)x0.85], was not reached at the highest dobutamine level, atropine was applied in 0.25 mg fractions (maximal dose 2 mg). Termination criteria were as previously published.4,8

Reader characteristics
Four readers (V.A.F.; F.E.R.; W.G.H.; E.N., with expertise in DSMR of 5–10 years involving 3–10 examinations per week) evaluated the examinations.

Image analysis
The DSMR examinations were anonymized and saved on the hard disk of four laptop computers being sent to the four readers. A PC-compatible dedicated viewing software (View Forum, Philips Medical Systems, The Netherlands) with a synchronized quadscreen image display was used for review of the DSMR examinations. The readers were supplied with the DSMR images only, thus being fully blinded to clinical, angiographic, and pharmacological stress-related data of the patients.

Each reader performed segmental analysis of LV wall motion by applying the standard visual scoring system to grade wall motion abnormalities (1, normokinesis, 2, hypokinesis, 3, akinesis, 4, dyskinesis) and documented the reading on a standardized evaluation sheet (17-segment model).9 Grading was done at rest and during dobutamine stress at 10 µg/kg/min, 20 µg/kg/min, and maximum stress level. Ischaemia was defined as more than one segment(s) showing an inducible wall motion abnormality (i.e. an increase in the segmental wall motion score of at least one) or a biphasic response. Other criteria for interpretation were not pre-arranged, no prior joint training session was organized.

Image quality was graded on a four-point scale as excellent, good, moderate, or non-diagnostic at each stress level and for each of the standard views.

Coronary arterial supply of myocardial segments was defined according to the guidelines of the American Heart Association,9 and for further analysis, the left anterior descending artery (LAD) and the combined right coronary artery (RCA)/left circumflex artery (LCX) territory were considered.

Quantitative coronary angiography
Coronary angiography was considered the standard of reference. The procedure was done according to the angiographic guidelines using a simultaneous biplane, multidirectional and isocentric X-ray system. At least two orthogonal views of every major coronary vessel and its side branches were acquired. Quantitative coronary angiography (Philips Inturis CardioView, QCA V3.3, Pie Medical Imaging) was performed off-line at the German Heart Institute Berlin by an independent observer (>10 years experience) being unaware of the results of CMR imaging. The contrast-filled catheter was used for image calibration. The severity of a coronary stenosis was derived from one single view showing the maximal reduction in absolute luminal diameter and a significant coronary stenosis was defined as ≥50% luminal diameter reduction in vessels with ≥2 mm diameter; a significant left main stenosis was considered double-vessel disease.

Statistical analysis
For all continuous parameters, mean±standard deviation are given. The paired Student's t-test was used to assess statistical significance of continuous variables. Group differences for categorical variables were tested with the {chi}2 or Fisher's exact test. All tests were two-tailed; P<0.05 was considered significant.

Sensitivity, specificity, positive/negative predictive value, and accuracy were calculated according to the standard definitions. To correct for possible correlations due to the structure of the data (four readings in each of 150 patients), confidence limits were calculated from a population-averaged mixed logistic regression model with patients as random effect and readers as fixed effect. For positive and negative predictive values, where reference populations are different between readers, confidence limits were calculated for each reader separately based on a binomial model as described by Clopper and Pearson.10 Readers were compared with respect to their diagnostic performance using F-tests of two-way analysis of variance models with the factors patient and reader.

Two different quantitative measures of agreement were used to allow comparisons to other publications. Cohen's kappa was applied to measure agreement between pairs of readers and averaged over all pairs to evaluate overall agreement11 using the following grading: 0–0.2 (poor), 0.21–0.4 (fair), 0.41–0.6 (moderate), 0.61–0.8 (substantial), and 0.81–1.0 (nearly perfect). However, because the kappa coefficient does not allow linear model building to evaluate the influence of covariates on agreement, an individually determined measure of disagreement was introduced that permitted identification of conditions of rather good and rather moderate agreement. This disagreement measure for 0/1 scale was determined as follows. First, for each reader, the average absolute difference to all other readers was calculated. Then, the reader-specific disagreements were averaged to obtain an overall measure of disagreement (D). The reported values of D represent the percentages of disagreement and are to be interpreted as follows. If disagreement is, for example, 10%, then two randomly selected readers will disagree in every 10th judgement.

General linear models were applied to evaluate the dependence of diagnostic performance and disagreement based on the presence or absence of significant CAD and the number of diseased coronary vessels.

Data analysis was performed using SPSS for Windows 11.5 (SPSS Inc.) and STATA 9.0.


    Results
 Top
 Abstract
 Introduction
 Methods
 Results
 Discussion
 Conclusions
 Acknowledgements
 References
 
Patient characteristics and dobutamine stress testing
Tables 1 and 2 summarize the clinical and haemodynamic data. One hundred and twenty-nine (86.0%) out of 150 patients reached target heart rate. The reasons for premature termination included chest pain and dyspnoea in six patients (4.2%), hypotension in one (0.7%), transient bradycardia in one (0.7%), arrhythmia in four (2.8%), and a new or worsening wall motion abnormality in nine (6.3%). In 57 patients (38.0%), there were wall motion abnormalities at rest in at least one segment (45 patients with hypokinesis and 12 with akinesis).


View this table:
[in this window]
[in a new window]
 
Table 1 Patient demographics

 

View this table:
[in this window]
[in a new window]
 
Table 2 LV function at rest and haemodynamic response during dobutamine stress

 
Diagnostic performance
Table 3 shows the diagnostic performance for all readers and each single reader (MR1–MR4). The sensitivities of the readers with regard to single-, double-, and triple-vessel disease were 75.0, 81.7, and 80.4%. In addition, sensitivity for the detection of inducible wall motion abnormalities being indicative of coronary luminal narrowing ≥50% did not significantly differ between patients with or without wall motion abnormalities at rest (81.6 and 75.0%, P=0.161).


View this table:
[in this window]
[in a new window]
 
Table 3 Diagnostic performance of all readers (mean) and each single DSMR Reader (MR1–MR4)

 
Disagreement in interpretation of DSMR
The values of the disagreement measure D provide the percentage of disagreement and are to be interpreted as follows. If a patient is randomly selected from the study population, and two readers are randomly selected, then a disagreement D of, for example, 10% indicates that two randomly selected readers will disagree in every 10th judgement.

In the present study, the readers disagreed in all patients in approximately every seventh case (14.9% of the cases) on test positivity or negativity. Disagreement of the DSMR readers was similar in patients with or without CAD (15.2 and 12.7,%, respectively; P=0.130) and was not significantly influenced by the number of diseased coronary vessels (18.2, 11.0, and 18.8% in single-, double-, and triple-vessel disease, respectively; P=0.063).

Agreement in interpretation of DSMR
The average kappa coefficient of agreement regarding the presence or absence of inducible wall motion was 0.59 for all readers; the kappa values ranged from 0.52 (MR1 and MR4) to 0.76 (MR3 and MR4).

For the assignment of inducible wall motion abnormalities to the LAD or the combined RCA/LCX territory, the average kappa value of agreement was 0.51 (range from 0.39 to 0.78).

Image quality of the single-centre image database
Image quality was considered to be good/excellent in 96.4% of standard views (Figure 1).


Figure 8831
View larger version (11K):
[in this window]
[in a new window]
 
Figure 1 Image quality. The bar graphs display the per cent of standard views judged as non-diagnostic, moderate, good, or excellent.

 
Representative examples of DSMR examinations are given in Figure 2A and B.


Figure 8832
View larger version (111K):
[in this window]
[in a new window]
 
Figure 2 (A) Cine images of the DSMR examination (apical short axis and four-chamber view) in a patient with single-vessel disease of the LAD. The four readers showed perfect agreement regarding newly developed wall motion abnormalities in the anterior and anteroseptal segment and the apex (segment 17); for a synchronized quadscreen movie display, see movie 1 (short-axis view) and movie 2 (four-chamber view). (B) Cine images of the DSMR examination (apical short axis and four-chamber view) in a patient with triple-vessel disease (significant stenoses of the first diagonal branch, proximal left circumflex, and distal RCA). The four readers detected newly developed wall motion abnormalities in the lateral wall (apical and equatorial segments). The development of a mitral regurgitation jet due to ischaemic papillary muscle dysfunction is depicted as well; for a synchronized quadscreen movie display, see movie 3 (short-axis view) and movie 4 (four-chamber view).

 

    Discussion
 Top
 Abstract
 Introduction
 Methods
 Results
 Discussion
 Conclusions
 Acknowledgements
 References
 
Our data show that (i) multiple observers from different institutions performing a diagnostic reading of DSMR achieve a high diagnostic accuracy in detection of inducible LV wall motion abnormalities in patients with significant CAD, (ii) disagreement of experienced DSMR readers occurs in approximately every seventh case and reader agreement regarding test positivity or negativity results in a kappa value of 0.59, (iii) diagnostic performance and disagreement of experienced DSMR readers are independent of the presence of CAD and the number of diseased coronary vessels, and (iv) image quality of the DSMR approach as routinely used at the single centre is consistently high.

In previous studies using high-dose DSMR, high diagnostic accuracies have been reported ranging from 82 to 88%,46 and its superiority in comparison to dobutamine stress echocardiography has been shown, especially in patients with suboptimal echocardiographic image quality.4,6

CMR imaging of LV function is technically easy to perform and has been well standardized with respect to image acquisition strategies. As the technique is now regarded as highly reproducible and reliable for the assessment of LV function and wall motion, the variability of visual wall motion assessment remains the most influential component and may limit its diagnostic value for detection of patients with significant CAD.

The diagnostic accuracy achieved in the current, fully blinded read lies within the range of previously published data on DSMR46 and thus further confirms its reliability in detection of significant CAD. Importantly, diagnostic accuracy and reader disagreement of DSMR were not influenced by the presence or absence of CAD or the number of diseased vessels. This is an advantage over stress echocardiography, for which a higher diagnostic accuracy and reader agreement have been shown in multiple-vessel disease.12

Image quality is regarded as one of the most important factors for the accuracy of dobutamine stress echocardiography.13,14 Despite consecutive inclusion of patients, in the present DSMR study, readers from different institutions graded >96% of images as excellent/good and only 0.4% of the standard views were regarded as non-diagnostic.

The paradigm is that excellent endocardial border delineation alone ensures high diagnostic accuracy and excellent reader agreement. In our fully blinded read, the diagnostic accuracy achieved by DSMR experts was consistently high and did not significantly differ. However, as reported for stress echocardiography, the readers obviously applied heterogeneous interpretation criteria leading either to a markedly specific (MR1 and MR2) or to a more ‘balanced’ reading with similarly high values for sensitivity and specificity (MR3 and MR4).

This is as well reflected by the agreement of all readers: though DSMR reader agreement was found to be only moderate (kappa value 0.59), it was clearly higher than that reported for stress echocardiography using fundamental imaging (kappa value 0.37, fair agreement) or second harmonic imaging with prior definition of uniform interpretation criteria (kappa value 0.55, moderate agreement).12,15 Of note, the kappa value of two DSMR readers was 0.76 (MR3 and MR4), which represents substantial agreement.

It is noteworthy, though, that in face of only moderate overall reader agreement of DSMR experts, standardized reading criteria need to be set for DSMR, despite the consistently high diagnostic accuracy achieved in the present study. The impact of uniform reading and analysis criteria on image interpretation has been described for other imaging modalities also and generally, a higher agreement could be demonstrated when these interpretation criteria were followed (e.g. for myocardial perfusion scintigrams, the kappa value could be increased from 0.45 to 0.66).16

It can reasonably be assumed that in clinical routine further improvements of DSMR accuracy will most likely rely on (i) implementation of standardized reading criteria and specific training for DSMR readers and (ii) potential methods to quantify regional wall motion. In preliminary studies, it has been shown that the application of myocardial tagging may help to better characterize the regional myocardial function17,18 and identify additional patients with significant CAD.19 Real-time analysis tools for direct visualization of regional myocardial strain (e.g. FastHARP) are becoming available and their value is being currently assessed.20,21

Study limitations
Patients with contraindications to CMR imaging (non-compatible biometallic implants, claustrophobia) were not included and patients with claustrophobia can account for as much as 4–6% in a similar population.2,22 Thus, even though DSMR testing may not be applicable in all patients, the diagnostic value is high in all eligible patients.

Currently, only a few centres perform DSMR in daily clinical routine and thus, the number of experienced readers is limited. The present study did not assess how much and what kind of training is necessary to achieve the level of an experienced DSMR reader. Further studies are needed to address this issue in order to provide clear recommendations for a specific training and to ensure high-quality reading of DSMR.

For our study, we used the angiographically defined coronary diameter reduction as the standard of reference. Yet, it is known from invasive measurements of coronary flow reserve that the haemodynamical relevance of coronary luminal stenoses may vary considerably.23,24 The haemodynamic consequences of stenotic lesions, and thus the resultant ischaemic response of the myocardium, depend on several other parameters as well, e.g. stenosis morphology (excentricity), stenosis location (bifurcational lesions) or the combined flow limiting effects of serial stenoses.25 Our aim, though, was to predict, whether invasive therapy was required for a given patient in a routine clinical setting, and to determine the value of DSMR as a ‘gatekeeper’ for further invasive testing and therapy.

Commonly, non-invasive testing is conducted prior to invasive coronary angiography and, thus, the interpreter is unaware of the coronary dominance type; in addition, it has been recognized that the inferolateral region exhibits an extensive overlap of coronary arterial supply corresponding to the RCA and LCX territory.9,26 Thus, for our territorial analysis, we considered the combined RCA/LCX territory.


    Conclusions
 Top
 Abstract
 Introduction
 Methods
 Results
 Discussion
 Conclusions
 Acknowledgements
 References
 
In the setting of multiple observers from different institutions performing a diagnostic reading of DSMR examinations conducted at a single centre, DSMR proved to be a reliable test for the detection of significant CAD with experienced DSMR readers achieving a high diagnostic accuracy. Disagreement regarding test positivity or negativity occurred in every seventh case. DSMR correctly identified patients with significant CAD independent of the number of diseased coronary vessels. Image quality of the DSMR technique as routinely performed at the single centre was highly rated. When compared with the diagnostic performance of available techniques, the present DSMR approach is sufficient to be incorporated into clinical decision-making in patients with suspected or known CAD.


    Acknowledgements
 Top
 Abstract
 Introduction
 Methods
 Results
 Discussion
 Conclusions
 Acknowledgements
 References
 
We are indebted to our CMR staff for expert assistance during the stress examinations, to Uwe Koehler, PhD, and Philip Krueger, PhD for their invaluable technical support during generation of the PC image database, and to Uwe Kokartis for performing the quantitative angiographic measurements. We thank Philips Medical Systems for supplying the PC-based CMR viewing software (Marc Kouwenhoven and Bert Verdonck).

Conflict of interest: none declared.


    Footnotes
 
This paper was guest edited by Prof. Dr Markus Schwaiger, Klinik r.d. Isar der TU Muenchen, München, Germany


    References
 Top
 Abstract
 Introduction
 Methods
 Results
 Discussion
 Conclusions
 Acknowledgements
 References
 

  1. Pennell DJ, Sechtem UP, Higgins CB, Manning WJ, Pohost GM, Rademakers FE, van Rossum AC, Shaw LJ, Yucel EK. (2004) Clinical indications for cardiovascular magnetic resonance (CMR): Consensus Panel report. Eur Heart J 25:1940–1965.[Free Full Text]
  2. Wahl A, Paetsch I, Gollesch A, Roethemeyer S, Foell D, Gebker R, Langreck H, Klein C, Fleck E, Nagel E. (2004) Safety and feasibility of high-dose dobutamine-atropine stress cardiovascular magnetic resonance for diagnosis of myocardial ischaemia: experience in 1000 consecutive cases. Eur Heart J 25:1230–1236.[Abstract/Free Full Text]
  3. Thiele H, Nagel E, Paetsch I, Schnackenburg B, Bornstedt A, Kouwenhoven M, Wahl A, Schuler G, Fleck E. (2001) Functional cardiac MR imaging with steady-state free precession (SSFP) significantly improves endocardial border delineation without contrast agents. J Magn Reson Imaging 14:362–367.[CrossRef][ISI][Medline]
  4. Nagel E, Lehmkuhl HB, Bocksch W, Klein C, Vogel U, Frantz E, Ellmer A, Dreysse S, Fleck E. (1999) Noninvasive diagnosis of ischemia-induced wall motion abnormalities with the use of high-dose dobutamine stress MRI: comparison with dobutamine stress echocardiography. Circulation 99:763–770.[Abstract/Free Full Text]
  5. Wahl A, Paetsch I, Roethemeyer S, Klein C, Fleck E, Nagel E. (2004) High-dose dobutamine-atropine stress cardiovascular magnetic resonance for follow-up after coronary revascularization procedures in patients with wall motion abnormalities at rest. Radiology 233:210–216.[Abstract/Free Full Text]
  6. Hundley WG, Hamilton CA, Thomas MS, Herrington DM, Salido TB, Kitzman DW, Little WC, Link KM. (1999) Utility of fast cine magnetic resonance imaging and display for the detection of myocardial ischemia in patients not well suited for second harmonic stress echocardiography. Circulation 100:1697–1702.[Abstract/Free Full Text]
  7. Hundley WG, Morgan TM, Neagle CM, Hamilton CA, Rerkpattanapipat P, Link KM. (2002) Magnetic resonance imaging determination of cardiac prognosis. Circulation 106:2328–2333.[Abstract/Free Full Text]
  8. Nagel E, Lorenz C, Baer F, Hundley WG, Wilke N, Neubauer S, Sechtem U, van der Wall E, Pettigrew R, de Roos A, Fleck E, van Rossum A, Pennell DJ, Wickline S, Rerkpattanapipat P, Link KM, Hamilton CA. (2001) Stress cardiovascular magnetic resonance: consensus panel report. Detecting left ventricular myocardial ischemia during intravenous dobutamine with cardiovascular magnetic resonance imaging (MRI). J Cardiovasc Magn Reson 3:267–281.[CrossRef][ISI][Medline]
  9. Cerqueira MD, Weissman NJ, Dilsizian V, Jacobs AK, Kaul S, Laskey WK, Pennell DJ, Rumberger JA, Ryan T, Verani MS. (2002) Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart. A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association. Int J Cardiovasc Imaging 18:539–542.[ISI][Medline]
  10. Clopper C and Pearson C. (1934) The use of confidence or fiducial limits illustrated in the case of the binomial. Biometrika 26:404–413.[Free Full Text]
  11. Cohen J. (1960) A coefficient of agreement for nominal scales. Educ Psychol Measurement 20:37–46.[CrossRef]
  12. Hoffmann R, Lethen H, Marwick T, Arnese M, Fioretti P, Pingitore A, Picano E, Buck T, Erbel R, Flachskampf FA, Hanrath P. (1996) Analysis of interinstitutional observer agreement in interpretation of dobutamine stress echocardiograms. J Am Coll Cardiol 27:330–336.[Abstract]
  13. Franke A, Hoffmann R, Kuhl HP, Lepper W, Breithardt OA, Schormann M, Hanrath P. (2000) Non-contrast second harmonic imaging improves interobserver agreement and accuracy of dobutamine stress echocardiography in patients with impaired image quality. Heart 83:133–140.[Abstract/Free Full Text]
  14. Nixdorff U, Matschke C, Winklmaier M, Flachskampf FA, Ludwig J, Pohle K, Land M, Gefeller O, Daniel WG. (2001) Native tissue second harmonic imaging improves endocardial and epicardial border definition in dobutamine stress echocardiography. Eur J Echocardiogr 2:52–61.[Abstract/Free Full Text]
  15. Hoffmann R, Marwick TH, Poldermans D, Lethen H, Ciani R, van der Meer P, Tries HP, Gianfagna P, Fioretti P, Bax JJ, Katz MA, Erbel R, Hanrath P. (2002) Refinements in stress echocardiographic techniques improve inter-institutional agreement in interpretation of dobutamine stress echocardiograms. Eur Heart J 23:821–829.[Abstract/Free Full Text]
  16. Wackers FJ, Bodenheimer M, Fleiss JL, Brown M. (1993) Factors affecting uniformity in interpretation of planar thallium-201 imaging in a multicenter trial. The Multicenter Study on Silent Myocardial Ischemia (MSSMI) Thallium-201 Investigators. J Am Coll Cardiol 21:1064–1074.[Abstract]
  17. Scott CH, Sutton MS, Gusani N, Fayad Z, Kraitchman D, Keane MG, Axel L, Ferrari VA. (1999) Effect of dobutamine on regional left ventricular function measured by tagged magnetic resonance imaging in normal subjects. Am J Cardiol 83:412–417.[CrossRef][ISI][Medline]
  18. Paetsch I, Foll D, Kaluza A, Luechinger R, Stuber M, Bornstedt A, Wahl A, Fleck E, Nagel E. (2005) Magnetic resonance stress tagging in ischaemic heart disease. Am J Physiol Heart Circ Physiol 288:H2708–H2714.[Abstract/Free Full Text]
  19. Kuijpers D, Ho KY, van Dijkman PR, Vliegenthart R, Oudkerk M. (2003) Dobutamine cardiovascular magnetic resonance for the detection of myocardial ischemia with the use of myocardial tagging. Circulation 107:1592–1597.[Abstract/Free Full Text]
  20. Garot J, Bluemke DA, Osman NF, Rochitte CE, McVeigh ER, Zerhouni EA, Prince JL, Lima JA. (2000) Fast determination of regional myocardial strain fields from tagged cardiac images using harmonic phase MRI. Circulation 101:981–988.[Abstract/Free Full Text]
  21. Kraitchman DL, Sampath S, Castillo E, Derbyshire JA, Boston RC, Bluemke DA, Gerber BL, Prince JL, Osman NF. (2003) Quantitative ischemia detection during cardiac magnetic resonance stress testing by use of FastHARP. Circulation 107:2025–2030.[Abstract/Free Full Text]
  22. Francis JM and Pennell DJ. (2000) Treatment of claustrophobia for cardiovascular magnetic resonance: use and effectiveness of mild sedation. J Cardiovasc Magn Reson 2:139–141.[ISI][Medline]
  23. Wilson RF, Marcus ML, White CW. (1987) Prediction of the physiologic significance of coronary arterial lesions by quantitative lesion geometry in patients with limited coronary artery disease. Circulation 75:723–732.[Abstract/Free Full Text]
  24. Pijls NH, De Bruyne B, Peels K, Van Der Voort PH, Bonnier HJ, Bartunek JKJJ, Koolen JJ. (1996) Measurement of fractional flow reserve to assess the functional severity of coronary-artery stenoses. N Engl J Med 334:1703–1708.[Abstract/Free Full Text]
  25. Pijls NH, De Bruyne B, Bech GJ, Liistro F, Heyndrickx GR, Bonnier HJ, Koolen JJ. (2000) Coronary pressure measurement to assess the hemodynamic significance of serial stenoses within one coronary artery: validation in humans. Circulation 102:2371–2377.[Abstract/Free Full Text]
  26. Pereztol-Valdes O, Candell-Riera J, Santana-Boado C, Angel J, Aguade-Bruix S, Castell-Conesa J, Garcia EV, Soler-Soler J. (2005) Correspondence between left ventricular 17 myocardial segments and coronary arteries. Eur Heart J 26:2637–2643.[Abstract/Free Full Text]

Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?

Related articles in EHJ:

The demystification of magnetic resonance imaging?
Rainer Hoffmann
EHJ 2006 27: 1394-1395. [Extract] [Full Text]  



This article has been cited by other articles:


Home page
Circ Cardiovasc ImagingHome page
R. Gebker, C. Jahnke, R. Manka, A. Hamdan, B. Schnackenburg, E. Fleck, and I. Paetsch
Additional Value of Myocardial Perfusion Imaging During Dobutamine Stress Magnetic Resonance for the Assessment of Coronary Artery Disease
Circ Cardiovasc Imaging, September 1, 2008; 1(2): 122 - 130.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
E. Dall'Armellina, T. M. Morgan, S. Mandapaka, W. Ntim, J. J. Carr, C. A. Hamilton, J. Hoyle, H. Clark, P. Clark, K. M. Link, et al.
Prediction of Cardiac Events in Patients With Reduced Left Ventricular Ejection Fraction With Dobutamine Cardiovascular Magnetic Resonance Assessment of Wall Motion Score Index
J. Am. Coll. Cardiol., July 22, 2008; 52(4): 279 - 286.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
K. R. Nandalur, B. A. Dwamena, A. F. Choudhri, M. R. Nandalur, and R. C. Carlos
Diagnostic Performance of Stress Cardiac Magnetic Resonance Imaging in the Detection of Coronary Artery Disease: A Meta-Analysis
J. Am. Coll. Cardiol., October 2, 2007; 50(14): 1343 - 1353.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
R. Hoffmann
The demystification of magnetic resonance imaging?
Eur. Heart J., June 2, 2006; 27(12): 1394 - 1395.
[Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
27/12/1459    most recent
ehi883v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Related articles in EHJ
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (5)
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Paetsch, I.
Right arrow Articles by Nagel, E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Paetsch, I.
Right arrow Articles by Nagel, E.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?