Skip Navigation


European Heart Journal Advance Access originally published online on April 30, 2007
European Heart Journal 2007 28(10):1190-1192; doi:10.1093/eurheartj/ehm110
This Article
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
28/10/1190    most recent
ehm110v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Related articles in EHJ
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Van Camp, G.
Right arrow Articles by Cosyns, B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Van Camp, G.
Right arrow Articles by Cosyns, B.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The European Society of Cardiology 2007. All rights reserved. For Permissions, please e-mail: journals.permissions@oxfordjournals.org

Bio-effects of ultrasound contrast agents in daily clinical practice: fact or fiction?

Guy Van Camp, Steven Droogmans and Bernard Cosyns

Department of Cardiology, UZ Brussel, Laarbeeklaan 101, 1090 Brussels, Belgium

* Corresponding author. Tel: +32 2 476 32 52; fax: +32 2 477 68 40. E-mail address: guy.vancamp{at}uzbrussel.be

This editorial refers to ‘Release of cardiac bio-markers during high mechanical index contrast-enhanced echocardiography in humans’{dagger} by D. Vancraeynest et al., on page 1236

Ultrasound contrast agents (UCAs), delivered as peripheral venous injections, have been developed to enhance the ultrasound image quality. The current application, recognized by the FDA and European Medecines Agency (EMEA) is the enhancement of the left ventricular endocardial border or left ventricular opacification (LVO). These microbubbles with a diameter and an intravascular velocity similar to red blood cells travel through the myocardial capillaries and enable us to visualize myocardial perfusion during myocardial contrast echocardiography (MCE).1 These agents are also used to quantitate myocardial perfusion most of the time, especially for research purposes.2,3

Like all other contrast agents used in medicine, adverse events can also occur with UCAs.4 Allergic reactions though important are inherent to the use of contrast agents. Their existence, although sometimes very serious (anaphylactoid reactions), imply that the use of UCAs in clinical practice can only be supported if the additional diagnostic information is clinically relevant enough for patient management. The UCAs can only be used by experienced hands and in an environment where facilities for emergency care are immediately available.

Above all the previously mentioned ‘acceptable’ adverse events for a contrast agent, two major observations have questioned the safety of UCAs. First, the concomitant use of contrast agents and ultrasound leads to bio-effects demonstrated in experimental studies. Secondly, post-marketing analysis of 157 838 studies of Sonovue® brought to light 19 cases of severe non-fatal (0.012%) (strong relationship with UCAs) (18 of 19 were anaphylactoid or vasovagal reactions) and three cases of fatal adverse events (0.002%) (causal relationship uncertain).5 For the first time, Vancraeynest et al.6 showed that MCE can cause sub-clinical release of bio-markers in humans. This observation could be the missing link between the demonstrated in vitro bio-effects of UCAs and some of the clinically reported adverse events with Sonovue®. What are the facts? What has been demonstrated in vitro in animals and in humans?

UCAs contain microbubbles with a diameter of <5 µm, filled with a perfluorocarbon gas, and surrounded by a shell. Because of these characteristics, they can pass through the pulmonary capillary filter. Due to their acoustic properties, they considerably enhance the backscattering capabilities of blood, thereby imaging the cavity of the left ventricle and also the myocardium. Once they travel into the ultrasound field, they oscillate. These oscillations can result in linear backscatter at low acoustic pressure, nonlinear signals with harmonic frequencies at medium acoustic pressure, and microbubble disintegration at high acoustic pressure.7 Microbubbles are compressible, and at low acoustic pressure, microbubbles grow and shrink symmetrically around their equilibrium size (stable or non-inertial cavitation). At higher acoustic pressure, however, the expansion and contraction of microbubbles usually become unequal and exaggerated, leading to their destruction (inertial cavitation). Microbubble destruction by ultrasound is the basic principle for the quantification of myocardial blood flow by MCE.2 Bio-effects of UCAs have been demonstrated in numerous in vitro studies. Even linear bubble oscillations are sufficient to achieve rupture of lipid membranes.8 Sudden violent collapse of microbubbles can produce high-velocity fluid micro-jets that may penetrate into the adjacent membranes leading to pore formation (sonoporation).9,10 Inertial cavitation, which depends on microbubble shell composition, ultrasound frequency, pulse duration, and acoustic power, can lead to secondary shock waves, transient local high temperatures, and shear stress.1113 On the one hand, these bio-effects in vitro must draw the clinician's attention towards potential harmful adverse events in patients; on the other hand, it opens the door towards potential applications of UCAs in gene and drug delivery.14

The most common finding in animal studies examining the potential tissue damage and the risk of UCAs together with ultrasound was capillary rupture and haemorrhage or dye extravasations.15,16 It is, however, very dangerous to extrapolate these results towards the real-life scenario. Ultrasound energy (no tissue attenuation in the animal studies), duration of insonification, and microbubble concentrations are some examples of the exaggeration of UCA's adverse events suggested by these animal studies.

Serious adverse events with MCE in humans are rare. Ventricular premature beats were reported by van der Wouw et al. but this was not confirmed in other studies.17,18 Cosyns et al.19 could not find any tissue Doppler abnormality of the left ventricle in patients. Since tissue Doppler is considered as a very sensitive technique to diagnose even small, subclinical alterations of left ventricular systolic and diastolic functions, this observation is certainly reassuring. The large clinical experience accumulated so far in several clinical trials and in routine clinical practice of more than 2 million patients showing the very low side-effect potential of UCAs confirms their low toxicity potential. The three fatal adverse events in unstable patients with advanced coronary artery disease encountered with Sonovue® however, suggest that this UCA might play a triggering role in the development of a fatal event in this group of high-risk patients.5 The lower adverse event rate of Optison® (serious adverse event rate ≤0.002 vs. 0.014% for Sonovue® and no fatal adverse events with Optison®) is remarkable. As the shell of Sonovue® contains polyethylene glycol which is known to be associated with the occurrence of allergic reactions, this chemical of the UCA could be responsible for these adverse reactions. Another explanation for some of the adverse events and for the fatal adverse events could be the occurrence of bio-effects at the level of the coronary microcirculation. Knebel et al.20 did not find clinically relevant increases in serum markers for micro-necrosis, inflammation, and oxidative stress after contrast echocardiography, but in some patients cTnI increased (three-fold methodical variation). Vancraeynest et al. looked towards more subtle changes in biomarkers after contrast echocardiography. They found a significant increase in the arterio-venous difference (coronary sinus vs. arterial level) of cTnI only in those patients with high-MI (MI 1.5) intermittent imaging (every other beat) and with the use of PESDA (home made perfluorocarbon-enhanced sonicated dextrose albumin). This could be interpreted as the first demonstration of bio-effects of contrast echocardiography in humans. The following remarks have to be made, however, concerning the methods used in this paper. Thickness, compressibility, and elasticity of the microbubble shell are important factors in their susceptibility to ultrasound-mediated destruction.21 These properties may be very different among the available contrast agents. The results obtained in the present study with PESDA are difficult to extrapolate with other contrast agents. Increase in cTnI was only seen in the high-MI intermittent imaging group. The vast majority of contrast examinations worldwide are used, however, for endocardial border delineation. In this situation, LVO settings use lower MI and real-time imaging, thus considerably reducing the chance for bio-effects. The authors used continuous infusion of contrast. A continuous infusion of UCAs is used in the first place for the quantification of myocardial perfusion. As mentioned earlier, this is mainly used in research. In all the other situations, bolus injections are used permitting the administration of lower volumes of UCAs and also reducing the cost. The authors also used a stable triggering interval every other beat. This is never done in clinical practice. Quantification of myocardial perfusion is only possible by increasing the pulse interval. Refilling of the normal myocardium takes almost always more than one cardiac cycle. The probe was also maintained for 15 min in the same apical position. Prolonged contrast agents' destruction in the same scan plane is unlikely in human studies. In daily practice, the scan plane is frequently changed to evaluate multiple myocardial regions. These changes continuously shift the myocardial layer with microbubble destruction, and thereby reducing the possible bio-effects of UCAs. During the study no patient experienced clinically relevant adverse effects (no premature ventricular beats mentioned). Despite these remarks, the authors performed a difficult and technically very demanding study with a clear message. Using high-MI contrast echocardiography with PESDA, and intermittent imaging every other beat for 15 min maintaining the probe at a fixed apical position, they found a significant increase in the arterio-venous difference of cTnI.

In conclusion, in extreme situations, rarely seen in clinical practice, the concomitant use of ultrasound and contrast agents can lead to bio-effects in vitro, ex vivo, in animal studies, and in humans. The clinical relevance of these bio-effects in humans during real-life contrast echocardiography remains an unanswered question. It is, of course, possible that even subtle bio-effects can induce fatal adverse events in unstable patients with extensive coronary artery disease. In these patients, it seems reasonable to weigh the benefit of the use of contrast agents during echocardiography against the possible adverse events and to take into account the risk of alternative examinations that could be done instead of the contrast echocardiography.4 Once the decision is made that UCAs will be used, techniques using low volumes of contrast agents with low-MI imaging should be preferentially used. Each echolaboratory using UCAs should have experience with the use of UCAs and should be able to treat serious allergic reactions.

In spite of these rather modest safety concerns, UCAs have positively and considerably changed the diagnostic power of echocardiography. They can be used in daily practice to optimize our echocardiographic images and increase the diagnostic information with only a very low rate of adverse events.

Conflict of interest: none declared.

Footnotes

The opinions expressed in this article are not necessarily those of the Editors of the European Heart Journal or of the European Society of Cardiology.

{dagger} doi:10.1093/eurheartj/ehm051 Back

References

  1. Mayer S, Grayburn PA. Myocardial contrast agents: recent advances and future directions. Prog Cardiovasc Dis (2001) 44:33–44.[CrossRef][ISI][Medline]
  2. Wei K, Jayaweera AR, Firoozan S, Linka A, Skyba DM, Kaul S. Quantification of myocardial blood flow with ultrasound-induced destruction of microbubbles administered as a constant venous infusion. Circulation (1998) 97:473–483.[Abstract/Free Full Text]
  3. Van Camp G, Ay T, Pasquet A, London V, Bol A, Giselu G, Heyndrickx GR, Rafter P, Melin JA, Vanoverschelde JL. Quantification of myocardial blood flow and assessment of its transmural distribution with real-time power modulation myocardial contrast. J Am Soc Echocardiogr (2003) 16:263–270.[CrossRef][ISI][Medline]
  4. Dijkmans PA, Visser CA, Kamp O. Adverse reactions to ultrasound contrast agents: is the risk worth the benefit? Eur J Echocardiogr (2005) 6:363–366.[Abstract/Free Full Text]
  5. Scientific Discussion. European Medicines Agency. (2004) CPMP/0053/01.
  6. Vancraeynest D, Kefer J, Hanet C, Fillee C, Beauloye C, Pasquet A, Gerber BL, Philippe M, Vanoverschelde J-LJ. Release of cardiac bio-markers during high mechanical index contrast-enhanced echocardiography in humans. Eur Heart J (2007) 28:1236–1241.[Abstract/Free Full Text]
  7. Von Wibra H, Voigt JU, Froman M, Bone D, Wranne B, Juhlin-Dannfeldt A. Interaction of microbubbles with ultrasound. Echocardiography (1999) 16:733–741.[ISI][Medline]
  8. Marmottant P, Hilgenfeldt S. Controlled vesicle deformation and lysis by single oscillating bubbles. Nature (2003) 423:153–156.[CrossRef][Medline]
  9. Miller DL, Quddus J. Sonoporation of monolayer cells by diagnostic ultrasound activation of contrast agent gas bodies. Ultrasound Med Biol (2000) 26:661–667.[CrossRef][ISI][Medline]
  10. Brujan EA. The role of cavitation microjets in the therapeutic applications of ultrasound. Ultrasound Med Biol (2004) 30:381–387.[CrossRef][ISI][Medline]
  11. Dayton PA, Morgan KE, Klibanov AL, Brandenburger GH, Ferrara KW. Optical and acoustical observations on the effects of ultrasound on contrast agents. IEEE Trans Ultrason Ferroelectr Control (1999) 46:220–232.[CrossRef]
  12. Zhong P, Lin H, Xi X, Zhu S, Bhoghte ES. Shock wave-inertial microbubble interaction: methodology, physical characterization, and bioeffect study. J Acoust Soc Am (1999) 105:1997–2009.[CrossRef][ISI][Medline]
  13. Wu J. Theoretical study on shear stress generated by microstreaming surrounding contrast agents attached to living cells. Ultrasound Med Biol (2002) 28:125–129.[CrossRef][ISI][Medline]
  14. Bekeredjian R, Grayburn PA, Shohet RV. Use of ultrasound contrast agents for gene or drug delivery in cardiovascular medicine. J Am Coll Cardiol (2005) 45:329–335.[Abstract/Free Full Text]
  15. Ay T, Havaux X, Van Camp G, Campanelli B, Gisellu G, Pasquet A, Denef JF, Melin JA, Vanoverschelde JL. Destruction of contrast microbubbles by ultrasound: effects on myocardial function, coronary perfusion pressure, and microvascular integrity. Circulation (2001) 104:461–466.[Abstract/Free Full Text]
  16. Miller DL, Quddus J. Diagnostic ultrasound activation of contrast agent gas bodies induces capillary rupture in mice. Proc Natl Acad Sci USA (2000) 97:10179–10184.[Abstract/Free Full Text]
  17. van der Wouw PA, Brauns AC, Bailey SE, Powers JE, Wilde AAA. Premature ventricular contractions during triggered imaging with ultrasound contrast. J Am Soc Echocardiogr (2000) 13:288–294.[CrossRef][ISI][Medline]
  18. Raisinghani A, Wei KS, Crouse L, Villanueva F, Feigenbaum H, Schiller NB, Weiss J, Naqvi TZ, Siegel R, Monaghan M, Goldman JH, Demaria A, POINT Investigators. Myocardial contrast echocardiography with triggered ultrasound does not cause premature ventricular complexes: evidence from PB127 studies. J Am Soc Echocardiogr (2003) 16:1037–1042.[CrossRef][ISI][Medline]
  19. Cosyns B, Weytjens C, Vanderhoogstrate M, Daniels C, Schoors D, Van Camp G. Tissue Doppler imaging does not show infraclinical alteration of myocardial function after contrast echocardiography. Eur J Echocardiogr (2005) 6:238–242.[Abstract/Free Full Text]
  20. Knebel F, Schimke I, Eddicks S, Walde T, Ziebig R, Schattke S, Bauman G, Borges AC. Does contrast echocardiography induce increases in markers of myocardial necrosis, inflammation and oxidative stress suggesting myocardial injury? Cardiovasc Ultrasound (2005) 3:21–29.[CrossRef][Medline]
  21. May DJ, Allen JS, Ferrera KW. Dynamics and fragmentation of thick-shelled microbubbles. IEEE Trans Ultrason Ferroelectr Freq Control (2002) 49:1400–1410.[CrossRef][ISI][Medline]

Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?

Related articles in EHJ:

Release of cardiac bio-markers during high mechanical index contrast-enhanced echocardiography in humans
David Vancraeynest, Joelle Kefer, Claude Hanet, Catherine Fillee, Christophe Beauloye, Agnes Pasquet, Bernhard L. Gerber, Marianne Philippe, and Jean-Louis J. Vanoverschelde
EHJ 2007 28: 1236-1241. [Abstract] [Full Text]  



This article has been cited by other articles:


Home page
Eur J EchocardiogrHome page
G. Nucifora, N. A. Marsan, H.-M. J. Siebelink, J. M. van Werkhoven, J. D. Schuijf, M. J. Schalij, D. Poldermans, E. R. Holman, and J. J. Bax
Safety of contrast-enhanced echocardiography within 24 h after acute myocardial infarction
Eur J Echocardiogr, July 16, 2008; (2008) jen167v1.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
28/10/1190    most recent
ehm110v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Related articles in EHJ
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Van Camp, G.
Right arrow Articles by Cosyns, B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Van Camp, G.
Right arrow Articles by Cosyns, B.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?