Skip Navigation


European Heart Journal Advance Access originally published online on January 31, 2007
European Heart Journal 2007 28(12):1432; doi:10.1093/eurheartj/ehl495
This Article
Right arrow FREE Full Text (PDF) Freely available
Right arrow All Versions of this Article:
28/12/1432    most recent
ehl495v1
Right arrow E-letters: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (2)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Spencker, S.
Right arrow Articles by Zabel, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Spencker, S.
Right arrow Articles by Zabel, M.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The European Society of Cardiology 2007. All rights reserved. For Permissions, please e-mail: journals.permissions@oxfordjournals.org

Severe pacemaker lead perforation detected by an automatic home-monitoring system

Sebastian Spencker1,*, Dirk Mueller1, Andrea Marek1 and Markus Zabel2

1 Department of Cardiology, Campus Benjamin Franklin, University of Medicine Berlin, Berlin, Germany
2 Department of Cardiology and Pulmonology, Georg-August-University, Herzzentrum, Goettingen, Germany

* Corresponding author. Tel: +49 3084452349; fax: +49 3084452256. E-mail address: sebastian.spencker{at}charite.de

A 56-year-old woman complained about episodes of pre-syncope. Following ECG diagnosis of 2 : 1 conducting AV-block II°, she was referred to our cardiology department.

DDD pacemaker implantation was performed, and the patient was discharged free of symptoms. A routine chest X-ray confirmed the correct position of both atrial and ventricular leads. The implanted pacemaker (Biotronik Philos DR-T) was equipped with an automatic home-monitoring surveillance system. The system establishes telemetric contact with the pacemaker once in 24 h, and standard pacing parameters are transmitted. The treating physician is notified via fax if pathological measurements are encountered.

Four weeks after implantation, the patient's home-monitoring system delivered a message suggestive of dysfunction of the atrial lead. Compared with the previous daily lead impedance measurements, the lead impedance had suddenly increased to the pathological range.

The patient who was completely asymptomatic was called to attend the outpatient pacemaker clinic as soon as possible. Upon interrogation, complete loss of capture was found at the atrial lead. A potential of only 0.4 mV and the increase in lead impedance were also documented. CT-scan showed lead perforation and a considerable protrusion (3.2 cm) of the atrial lead through the cardiac wall into the upper lobe of the right lung. In surgical standby, the lead was removed and repositioned to the right atrial auriculum. The procedure was uneventful without the feared complication of pericardial tamponade.

This case is an example of the fast and possibly life-saving diagnostic capabilities for lead complications in modern home-monitoring equipped pacemakers.

Formula


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
EuropaceHome page
G. Andrikopoulos, S. Tzeis, G. Theodorakis, and P. Vardas
Monitoring capabilities of cardiac rhythm management devices
Europace, October 29, 2009; (2009) eup317v1.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
S. Spencker, N. Coban, L. Koch, A. Schirdewan, and D. Muller
Potential role of home monitoring to reduce inappropriate shocks in implantable cardioverter-defibrillator patients due to lead failure
Europace, April 1, 2009; 11(4): 483 - 488.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
J. C. Nielsen, H. Kottkamp, M. Zabel, E. Aliot, U. Kreutzer, A. Bauer, A. Schuchert, H. Neuser, B. Schumacher, H. Schmidinger, et al.
Automatic home monitoring of implantable cardioverter defibrillators
Europace, June 1, 2008; 10(6): 729 - 735.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
H. Heidbuchel, P. Lioen, S. Foulon, W. Huybrechts, J. Ector, R. Willems, and H. Ector
Potential role of remote monitoring for scheduled and unscheduled evaluations of patients with an implantable defibrillator
Europace, March 1, 2008; 10(3): 351 - 357.
[Abstract] [Full Text] [PDF]


This Article
Right arrow FREE Full Text (PDF) Freely available
Right arrow All Versions of this Article:
28/12/1432    most recent
ehl495v1
Right arrow E-letters: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (2)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Spencker, S.
Right arrow Articles by Zabel, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Spencker, S.
Right arrow Articles by Zabel, M.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?