European Heart Journal Advance Access originally published online on November 7, 2008
European Heart Journal 2008 29(24):3037-3042; doi:10.1093/eurheartj/ehn485
This Article
Right arrow Abstract Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow All Versions of this Article:
29/24/3037    most recent
ehn485v1
Right arrow E-letters: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Related articles in EHJ
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (15)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Herzog, B. A.
Right arrow Articles by Kaufmann, P. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Herzog, B. A.
Right arrow Articles by Kaufmann, P. A.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2008. For permissions please email: journals.permissions@oxfordjournals.org

Accuracy of low-dose computed tomography coronary angiography using prospective electrocardiogram-triggering: first clinical experience

Bernhard A. Herzog1, Lars Husmann1, Nina Burkhard1, Oliver Gaemperli1, Ines Valenta1, Fuminari Tatsugami1, Christophe A. Wyss1, Ulf Landmesser1 and Philipp A. Kaufmann1,2,*

1 Cardiovascular Center, Raemistrasse 100, University Hospital Zurich, Raemistrasse 100, 8091 Zurich, Switzerland
2 Zurich Center for Integrative Human Physiology (ZIHP), University of Zurich, Zurich, Switzerland

Received 6 February 2008; revised 19 September 2008; accepted 9 October 2008; online publish-ahead-of-print 7 November 2008.

* Corresponding author. Tel: +41 44 255 4196, Fax: +41 44 255 4414, Email: pak{at}usz.ch

See page 2955 for the editorial comment on this article (doi:10.1093/eurheartj/ehn518)


    Abstract
 Top
 Abstract
 Introduction
 Methods
 Results
 Discussion
 Funding
 References
 
Aims: To evaluate the accuracy of low-dose computed tomography coronary angiography (CTCA) using prospective ECG-triggering for the assessment of coronary artery disease (CAD).

Methods and results: A total of 30 patients (19 males, 11 females, mean age 58.8 ± 9.9 years) underwent low-dose CTCA and invasive coronary angiography (CA) [median 2 days (0, 41)]. Before CT scanning, intravenous beta-blocker was administered in 18 of 30 patients as heart rate (HR) was >65 b.p.m., achieving a mean HR of 55.7 ± 7.9 b.p.m. CAD was defined as coronary artery narrowing ≥50%, using CA as standard of reference. The estimated mean effective radiation dose was 2.1 ± 0.7 mSv (range: 1.0–3.3), yielding 96.0% (383/399) of evaluable segments. On an intention-to-diagnose-base, all non-evaluative segments were included in the analysis. Vessels with a non-evaluative segment and no further finding were censored as false positive. Patient-based analysis revealed sensitivity, specificity, positive predictive value, and negative predictive value of 100, 83.3, 90.0, and 100%, respectively. The respective values per vessel were 100, 88.9, 85.7, and 100%, respectively.

Conclusion: Prospective ECG-triggering allows low-dose CTCA and provides high diagnostic accuracy in the assessment of CAD in patients with stable sinus rhythm and a low heart rate.

Key Words: CT coronary angiography • Diagnostic accuracy • Low dose • Prospective ECG-triggering • Image quality


    Introduction
 Top
 Abstract
 Introduction
 Methods
 Results
 Discussion
 Funding
 References
 
The implementation of 64-multidetector computed tomography (CT) has been a milestone for the introduction of CT coronary angiography (CTCA) as diagnostic tool for non-invasive assessment of coronary artery stenoses in the clinical routine.17 Throughout all technical advances, the two main challenges still remain motion-free depiction of coronary arteries and reduction of radiation exposure to the patient. Although new developments such as dual-source technology814 and latest scanner generations with 25615 and more slices16 may help reducing motion artefacts, the issue of radiation is not solved by these technical advances. In fact, in a preliminary study using 256 slices, radiation administered to the patient has been reported as high as 33 mSv.15 In view of the ongoing debate on the radiation burden of CTCA and its risk of cancer induction,17 any suggestion to successfully reduce radiation dose is important. Introduction of tube modulation by electrocardiogram has reduced radiation from over 20 mSv4 to 10–15 mSv,2 and optimized protocols have achieved doses as low as <8 mSv.18

The most promising approach for dose reduction seems to be the use of a new scanning protocol applying prospective ECG triggering, where radiation is administered only at one predefined end-diastolic time point instead of during a whole phase of the cardiac cycle.19

A recent report has demonstrated the clinical feasibility of such low-dose CTCA with prospective triggering to achieve diagnostic image quality despite reduction of radiation dose by almost an order of magnitude.20 However, no data on the accuracy of CTCA by prospective triggering compared with invasive CA are available so far.

Thus, the purpose of our study was to investigate the accuracy of low-dose CTCA using prospective ECG triggering for the assessment of coronary stenoses in comparison with invasive CA.


    Methods
 Top
 Abstract
 Introduction
 Methods
 Results
 Discussion
 Funding
 References
 
Study population
The present study evaluated patients with suspected chronic stable coronary artery disease (CAD). We decided to aim at including 30 patients into the final analysis of this preliminary report, although no formal sample size calculation was performed due to the pilot nature of this study. Among 112 consecutive patients referred for elective invasive CA, 70 patients deemed ineligible due to known significant CAD. Four of the remaining 42 patients refused to give the consent and eight were excluded due to allergy to iodinated contrast agent (n = 1), nephropathy (creatinine levels >150 µmol/L or >1.7 mg/dL) (n = 4), non-sinus rhythm, known premature ventricular, or supraventricular beats (n = 3). The 30 patients included in our final analysis were referred for the following symptoms: dyspnoea (n = 3), typical angina pectoris (n = 9), atypical chest pain (n = 10), pathological exercise test, or ECG (n = 11). All patients underwent both invasive CA and CTCA. The study protocol was approved by the local ethics committee and written informed consent was obtained from patients included in the study.

Data acquisition and post-processing
All patients received a single dose of 2.5 mg isosorbiddinitrate sublingual (Isoket, Schwarz Pharma, Monheim, Germany) 2 min prior to the scan. In addition, intravenous metoprolol (2–20 mg) (Beloc, AstraZeneca, London, UK) was administered, if necessary to achieve a target HR of <65 b.p.m. prior to the start of the scan. The HR was monitored and HR variability was assessed as the standard deviation of the HR throughout the scan as reported previously.21 For CTCA, 80 mL of iodixanol (Visipaque 320, 320 mg/mL, GE Heathcare, Buckinghamshire, UK) at a flow rate of 5 mL/s followed by 50 mL saline solution was injected into an antecubital vein through an 18-gauge catheter. Bolus tracking was performed with a region of interest placed into the ascending aorta, and image acquisition was started 4 s after the signal density reached a threshold of ~120 Hounsfield units (HU).

All CTCA examinations were performed with a LightSpeed VCT XT scanner (GE Healthcare) and prospective ECG triggering,19 using a commercially available protocol (SnapShot Pulse, GE Healthcare) and the following scanning parameters as previously reported:20 slice acquisition acquisition 64 x 0.625 mm, smallest X-ray window (only 75% of the RR-cycle), z-coverage 40 mm with an increment of 35 mm, gantry rotation time 350 ms, body mass index (BMI) adapted tube voltage (100 kV: BMI <25 kg/m2; 120 kV: BMI ≥25 kg/m2) and effective tube-current (450 mA: BMI <22.5 kg/m2; 500 mA: BMI 22.5–25 kg/m2; 550 mA: BMI 25–27.5 kg/m2; 600 mA: BMI 27.5–30 kg/m2; 650 mA: BMI >30 kg/m2). The CT scan was performed from below the tracheal bifurcation to the diaphragm, choosing three to four scan blocks (field of view 11–14.5 cm). By restricting the scan to the smallest possible window at only one distinct end-diastolic phase of the RR-cycle (i.e. 75%), we ascertained the lowest achievable effective dose delivery.

The effective dose from CTCA was calculated as the product of the dose-length product (DLP) times a conversion coefficient for the chest (k = 0.017 mSv/mGy cm) as previously suggested.22 The CTCA images were reconstructed with a slice thickness of 0.6 mm, using a medium-soft tissue convolution kernel (standard). In case of vessel wall calcifications, additional images were reconstructed using a sharp-tissue convolution kernel (detail) and preferably analysed using a bone window setting (window width: 1500 HU; window level: 500 HU) to compensate for blooming artefacts. All images were transferred to an external workstation (AW 4.4, GE Healthcare).

Computed tomography image analysis
Coronary arteries were segmented as suggested by the American Heart Association.23 The right coronary artery was defined to include segments 1–4, the left main artery and the left anterior descending (LAD) artery to include segments 5–10, and the left circumflex artery (CX) to include segments 11–16; the intermediate artery was designated as segment 16, if present. All segments with a diameter of at least 1.5 mm at their origin were included. Two readers semi-quantitatively assessed independently the overall image quality on a four-point scale (1, excellent, no motion artefacts; 2, good, minor artefacts; 3, adequate, moderate artefacts; 4, non-evaluative, severe artefacts) as previously reported.14 Scores 1–3 were considered as diagnostic, score 4 as non-diagnostic. Step artefacts at junctions of different image blocks may not necessarily lead to misinterpretations. However, as a hidden lesion within the artefact cannot be excluded with absolute certainty, we have categorized any step artefact as non-evaluative. Both readers assessed all coronary vessels for the presence of haemodynamically significant stenoses, defined as narrowing of the coronary luminal diameter ≥50%. In case of multiple lesions in one segment, the segment was classified by the worst lesion. For any disagreement in data analysis between the two observers, consensus agreement was achieved.

Invasive coronary angiography
Invasive CA was performed according to standard techniques, and multiple views were stored on a CD-ROM. An experienced observer blinded to the results from CTCA evaluated the angiograms. The coronary arteries were subdivided according to the same model used for the CT angiography images23 and were quantitatively assessed with the use of an automated edge-detection system (Xcelera 1.2; Philips Medical Systems, Best, the Netherlands) as reported previously.24 In brief, quantitative CA measurements were performed in two image planes and included the diameter of the reference vessel (proximal and distal to the stenosis), the minimal luminal diameter, and the extent of stenosis (defined as the diameter of the reference vessel minus the minimal luminal diameter, divided by the reference diameter and multiplied by 100%). For biplane assessment, diameters obtained in both image planes were averaged. Coronary arteries were included in the analysis if luminal diameter was at least 1.5 mm; excluding those vessels distal to complete occlusions. Each vessel was scored as being normal or significantly stenosed (defined as a diameter reduction of ≥50%).

Statistical analysis
Quantitative variables were expressed as mean ± standard deviation and categorical variables as frequencies, median (25th, 75th percentiles) or percentages.

Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated; invasive CA was considered the standard of reference. The 95% confidence intervals (CI) were calculated from binomial expression per vessel and per patient. We took into account the clustered nature of the data (i.e. the fact that the 90 vessel were not independent but instead clusters of vessels in 30 patients). For these analyses, a proportion-procedure for survey data of the Stata software (StataCorp 10.0, College Station, USA) with patient as primary sample unit was performed to address dependencies between the vessels.25


    Results
 Top
 Abstract
 Introduction
 Methods
 Results
 Discussion
 Funding
 References
 
Computed tomography coronary angiography and CA were successfully performed in all 30 patients (19 males, 11 females, age 58.8 ± 9.9 years) [median 2 days (0, 41)]. Twelve patients were on beta-blocker therapy as part of their baseline medication. Using CTCA, additional intravenous beta-blocker was administered in 18 patients for HR control prior to CTCA (median 4.5 mg1,20 yielding a mean HR of 55.7 ± 7.9 b.p.m. (range: 35–70 b.p.m.) and a mean HR variability of 1.5 ± 0.9 b.p.m. (range: 0.3–3.7 b.p.m.). The mean BMI was 27.0 ± 4.9 kg/m2 (range: 21.9–42.5 kg/m2). The mean DLP was 125.8 ± 43.1 mGy cm (range: 58.3–192.7 mGy cm) resulting in an estimated mean effective radiation dose of 2.1 ± 0.7 mSv (range: 1.0–3.3 mSv). Of the 480 theoretically possible segments in 30 patients with 16 coronary segments, 52 were missing due to anatomical variants and 29 had a diameter of <1.5 mm at their origin (by both methods). Thus, 52 segments were missing for reasons not associated with the methodology as these segments did simply not exist. The remaining 29 segments were categorized as lower than 1.5 mm and thus not evaluable by the gold standard invasive CA. Thus, the missing data do not seem to introduce a selection bias.

Image quality with computed tomography coronary angiography
Image quality of 383/399 segments (96.0%) in 26/30 patients was diagnostic (score 1–3); excellent image quality (score 1) was rated in 133 segments (33.3%), good (score 2) in 146 segments (36.6%), and adequate (score 3) in 104 segments (26.1%). Sixteen segments (4.0%) in four of 30 patients were non-diagnostic (score 4) and were considered as false-positive. Two of these four patients had correctly identified lesions in other segments, re-categorizing these two as true positive patients. Table 1 shows demographic data and overall image quality.


View this table:
[in this window]
[in a new window]

 
Table 1 Patient demographics, overall image quality

 
Diagnostic accuracy of computed tomography coronary angiography in comparison with invasive coronary angiography
In 18 patients and 36 vessels, 66 coronary artery stenoses were recognized with invasive CA. Single-vessel disease was present in eight patients, two-vessel disease in two patients, and three-vessel disease in eight patients. Figure 1 demonstrates an example of coronary artery stenosis detection by CTCA and CA.


Figure 1
View larger version (64K):
[in this window]
[in a new window]
[Download PowerPoint slide]
 
Figure 1 Low-dose CT and invasive coronary angiography in a 42-year-old male patient with atypical chest pain. Right coronary artery (RCA), left anterior descending artery (LAD) artery and circumflex artery (CX) illustrated as volume-rendered images, (A) maximum intensity projections, (B) invasive coronary angiography images, and (C) stretched multiplanar reconstructions. The arrow head indicates a non-calcified significant stenosis in the proximal LAD.

 
Low-dose CTCA correctly detected CAD in all patients (n = 18) and in all vessels (n = 36) with lesions. Invasive CA revealed no CAD in 12 patients. CAD has been correctly ruled out by CTCA in 10 of 12 patients and in 48 of 54 vessels without coronary stenoses. Two patients were categorized as false positive. Six vessels were found to be false positive due to massive calcification (n = 2) or due to non-evaluative image quality caused by motion artefacts (n = 4). Of note, there was no false-negative finding, neither per vessel nor per patient (Table 2).


View this table:
[in this window]
[in a new window]

 
Table 2 Diagnostic accuracy

 
On a per-vessel analysis, there was 100% (36/36) sensitivity, 88.9% (48/54, 95% CI: 0.77–1.00) specificity, 85.7% (36/42, 95% CI: 0.70–1.00) PPV, and 100% (48/48) NPV.

On a per-patient analysis, there was 100% (18/18) sensitivity, 83.3% (10/12, 95% CI: 0.62–1.00) specificity, 90.0% (18/20, 95% CI: 0.76–1.00) PPV, and 100% (10/10) NPV (Table 2).


    Discussion
 Top
 Abstract
 Introduction
 Methods
 Results
 Discussion
 Funding
 References
 
The present study is the first to demonstrate the accuracy of low-dose CTCA using prospective ECG-triggering for the assessment of CAD in comparison with the reference standard invasive CA.

Radiation exposure to patients in CTCA has remained a source of concern, even after successful reduction down to 9.4 mSv in 64-slice MDCT26 and to 7.8 mSv in dual source CT18 by applying ECG-gated tube modulation and retrospective triggering. The present protocol using prospective ECG-triggering allows to further substantially reduce the effective radiation dose down to 2.1 ± 0.7 mSv, which compares favourably to the average of 7 mSv typically reported for a diagnostic invasive CA.22 Our results confirm the previously reported feasibility20 and document a high accuracy of low-dose CTCA, comparing well to results from retrospectively gating with 64-slice CT or dual-source CT.37,27,28

Interestingly, the NPV was excellent both on a per-patient and on per-vessel base. This is important as the main strength and the main clinical role of CTCA is thought to be exclusion of CAD in low-to-intermediate probability populations.29 The present study supports that low-dose CTCA can reliably rule out CAD.

A criticism often raised against CTCA studies has been the inclusion of high prevalence populations. This may also apply to our study. However, validation of a new CTCA protocol for the assessment of CAD requires comparison against the standard of reference, namely invasive CA. The latter, however, is affected by a small but distinct procedure-related morbidity (1.5%) and mortality rate (0.15%),30 precluding its use for purely scientific purposes in a low-probability population for ethical reasons. This may introduce a bias as patients with normal CTCA findings would not undergo invasive CA, which reduces true negative findings, resulting in an apparent decline in specificity.31 Therefore, we have included only patients who were referred for invasive CA due to clinical suspicion, which may explain the relatively high prevalence of CAD in our study. This strengthens the validity of our results with excellent NPV as in low-prevalence populations with more true positive findings the NPV is generally higher.32

In addition, patient groups which we generally perceived as most suitable for CTCA are typically younger and have less coronary calcifications. This would improve image quality and reduce false-positive findings. The large field of view in 256 or 320 multislice CT scanners allows acquisition of the whole coronary tree within one cardiac cycle eliminating any stair-step artefacts. Preliminary data confirm that the concept of prospective ECG triggering is applicable in latest scanner generations. Thus, although prospective ECG-triggering is still in its infancies, this scanning protocol has the potential to become a new standard.

We acknowledge the following limitation to our pilot study. First, we included a relatively small number of only 30 patients. However, the results appear valid as we have used an intention-to-diagnose strategy to achieve a clinically relevant endpoint, i.e. findings on a per-patient and per-vessel analysis. Furthermore, HR control is mandatory for prospective ECG triggering,20 explaining the frequent beta-blocker administration in this study, though the median dose of 4.5 mg1,20 intravenous metoprolol in our study compares well with previous reports.24,7,21,33 Nevertheless, as all patients turned out to have normal ejection fraction, we may have introduced a bias towards lower heart rates and/or eligibility for larger doses of intravenous metoprolol allowing to reach the target heart rate of <65 b.p.m. in each patient. Furthermore, by excluding patients with known coronary lesions, we may have introduced a bias towards younger age. This may result in less calcifications and also better ability to follow breath hold commands. Finally, CTCA with prospective ECG-triggering does not allow functional assessment of the left ventricle. This, however, is generally assessed primarily with other modalities such as echocardiography or a gated nuclear exam if hybrid imaging is performed.34

In conclusion, prospective ECG-triggering allows to acquire low-dose CTCA at radiation doses below those of invasive CA providing high diagnostic accuracy in the assessment of CAD in patients with stable sinus rhythm and a low heart rate.


    Funding
 Top
 Abstract
 Introduction
 Methods
 Results
 Discussion
 Funding
 References
 
The study has been supported by the Swiss National Science Foundation (SNSF-professorship grant no. PP00A-114706) and by the ZIHP (Zurich Center for Integrative Human Physiology, University of Zurich, Switzerland).

Conflict of interest: none declared.


    References
 Top
 Abstract
 Introduction
 Methods
 Results
 Discussion
 Funding
 References
 

  1. Ehara M, Surmely JF, Kawai M, Katoh O, Matsubara T, Terashima M, Tsuchikane E, Kinoshita Y, Suzuki T, Ito T, Takeda Y, Nasu K, Tanaka N, Murata A, Suzuki Y, Sato K, Suzuki T. Diagnostic accuracy of 64-slice computed tomography for detecting angiographically significant coronary artery stenosis in an unselected consecutive patient population: comparison with conventional invasive angiography. Circ J (2006) 70:564–571.[CrossRef][Web of Science][Medline]
  2. Leber AW, Knez A, von Ziegler F, Becker A, Nikolaou K, Paul S, Wintersperger B, Reiser M, Becker CR, Steinbeck G, Boekstegers P. Quantification of obstructive and nonobstructive coronary lesions by 64-slice computed tomography: a comparative study with quantitative coronary angiography and intravascular ultrasound. J Am Coll Cardiol (2005) 46:147–154.[Abstract/Free Full Text]
  3. Leschka S, Alkadhi H, Plass A, Desbiolles L, Grunenfelder J, Marincek B, Wildermuth S. Accuracy of MSCT coronary angiography with 64-slice technology: first experience. Eur Heart J (2005) 26:1482–1487.[Abstract/Free Full Text]
  4. Mollet NR, Cademartiri F, van Mieghem CA, Runza G, McFadden EP, Baks T, Serruys PW, Krestin GP, de Feyter PJ. High-resolution spiral computed tomography coronary angiography in patients referred for diagnostic conventional coronary angiography. Circulation (2005) 112:2318–2323.[Abstract/Free Full Text]
  5. Nikolaou K, Knez A, Rist C, Wintersperger BJ, Leber A, Johnson T, Reiser MF, Becker CR. Accuracy of 64-MDCT in the diagnosis of ischemic heart disease. AJR Am J Roentgenol (2006) 187:111–117.[Abstract/Free Full Text]
  6. Pugliese F, Mollet NR, Runza G, van Mieghem C, Meijboom WB, Malagutti P, Baks T, Krestin GP, deFeyter PJ, Cademartiri F. Diagnostic accuracy of non-invasive 64-slice CT coronary angiography in patients with stable angina pectoris. Eur Radiol (2006) 16:575–582.[CrossRef][Web of Science][Medline]
  7. Raff GL, Gallagher MJ, O'Neill WW, Goldstein JA. Diagnostic accuracy of noninvasive coronary angiography using 64-slice spiral computed tomography. J Am Coll Cardiol (2005) 46:552–557.[Abstract/Free Full Text]
  8. Brodoefel H, Burgstahler C, Tsiflikas I, Reimann A, Schroeder S, Claussen CD, Heuschmid M, Kopp AF. Dual-source CT: effect of heart rate, heart rate variability, and calcification on image quality and diagnostic accuracy. Radiology (2008) 247:346–355.[Abstract/Free Full Text]
  9. Ferencik M, Nomura CH, Maurovich-Horvat P, Hoffmann U, Pena AJ, Cury RC, Abbara S, Nieman K, Fatima U, Achenbach S, Brady TJ. Quantitative parameters of image quality in 64-slice computed tomography angiography of the coronary arteries. Eur J Radiol (2006) 57:373–379.[CrossRef][Web of Science][Medline]
  10. Herzog C, Arning-Erb M, Zangos S, Eichler K, Hammerstingl R, Dogan S, Ackermann H, Vogl TJ. Multi-detector row CT coronary angiography: influence of reconstruction technique and heart rate on image quality. Radiology (2006) 238:75–86.[Abstract/Free Full Text]
  11. Hoffmann MH, Shi H, Manzke R, Schmid FT, De Vries L, Grass M, Brambs HJ, Aschoff AJ. Noninvasive coronary angiography with 16-detector row CT: effect of heart rate. Radiology (2005) 234:86–97.[Abstract/Free Full Text]
  12. Hong C, Becker CR, Huber A, Schoepf UJ, Ohnesorge B, Knez A, Bruning R, Reiser MF. ECG-gated reconstructed multi-detector row CT coronary angiography: effect of varying trigger delay on image quality. Radiology (2001) 220:712–717.[Abstract/Free Full Text]
  13. Leschka S, Husmann L, Desbiolles LM, Gaemperli O, Schepis T, Koepfli P, Boehm T, Marincek B, Kaufmann PA, Alkadhi H. Optimal image reconstruction intervals for non-invasive coronary angiography with 64-slice CT. Eur Radiol (2006) 16:1964–1972.[CrossRef][Web of Science][Medline]
  14. Matt D, Scheffel H, Leschka S, Flohr TG, Marincek B, Kaufmann PA, Alkadhi H. Dual-source CT coronary angiography: image quality, mean heart rate, and heart rate variability. AJR Am J Roentgenol (2007) 189:567–573.[Abstract/Free Full Text]
  15. Motoyama S, Anno H, Sarai M, Sato T, Sanda Y, Ozaki Y, Mochizuki T, Katada K, Hishida H. Noninvasive coronary angiography with a prototype 256-row area detector computed tomography system: comparison with conventional invasive coronary angiography. J Am Coll Cardiol (2008) 51:773–775.[Free Full Text]
  16. Rybicki FJ, Otero HJ, Steigner ML, Vorobiof G, Nallamshetty L, Mitsouras D, Ersoy H, Mather RT, Judy PF, Cai T, Coyner K, Schultz K, Whitmore AG, Di Carli MF. Initial evaluation of coronary images from 320-detector row computed tomography. Int J Cardiovasc Imaging (2008) 24:535–546.[CrossRef][Web of Science][Medline]
  17. Einstein AJ, Henzlova MJ, Rajagopalan S. Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography. J Am Med Assoc (2007) 298:317–323.[Abstract/Free Full Text]
  18. Stolzmann P, Scheffel H, Schertler T, Frauenfelder T, Leschka S, Husmann L, Flohr TG, Marincek B, Kaufmann PA, Alkadhi H. Radiation dose estimates in dual-source computed tomography coronary angiography. Eur Radiol (2008) 18:592–599.[CrossRef][Web of Science][Medline]
  19. Hsieh J, Londt J, Vass M, Li J, Tang X, Okerlund D. Step-and-shoot data acquisition and reconstruction for cardiac x-ray computed tomography. Med Phys (2006) 33:4236–4248.[CrossRef][Web of Science][Medline]
  20. Husmann L, Valenta I, Gaemperli O, Adda O, Treyer V, Wyss CA, Veit-Haibach P, Tatsugami F, von Schulthess GK, Kaufmann PA. Feasibility of low-dose coronary CT angiography: first experience with prospective ECG-gating. Eur Heart J (2008) 29:191–197.[Abstract/Free Full Text]
  21. Leschka S, Wildermuth S, Boehm T, Desbiolles L, Husmann L, Plass A, Koepfli P, Schepis T, Marincek B, Kaufmann PA, Alkadhi H. Noninvasive coronary angiography with 64-section CT: effect of average heart rate and heart rate variability on image quality. Radiology (2006) 241:378–385.[Abstract/Free Full Text]
  22. Einstein AJ, Moser KW, Thompson RC, Cerqueira MD, Henzlova MJ. Radiation dose to patients from cardiac diagnostic imaging. Circulation (2007) 116:1290–1305.[Free Full Text]
  23. Austen WG, Edwards JE, Frye RL, Gensini GG, Gott VL, Griffith LS, McGoon DC, Murphy ML, Roe BB. A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association. Circulation (1975) 51:5–40.[Medline]
  24. Gaemperli O, Schepis T, Valenta I, Koepfli P, Husmann L, Scheffel H, Leschka S, Eberli FR, Luscher TF, Alkadhi H, Kaufmann PA. Functionally relevant coronary artery disease: comparison of 64-section CT angiography with myocardial perfusion SPECT. Radiology (2008) 248:414–423.[Abstract/Free Full Text]
  25. Eltinge JL, Scribney WM. Estimation of means, totals, ratios, and proportions for survey data. Stata Tech Bull (1997) 6:23–26.
  26. Hausleiter J, Meyer T, Hadamitzky M, Huber E, Zankl M, Martinoff S, Kastrati A, Schomig A. Radiation dose estimates from cardiac multislice computed tomography in daily practice: impact of different scanning protocols on effective dose estimates. Circulation (2006) 113:1305–1310.[Abstract/Free Full Text]
  27. Fine JJ, Hopkins CB, Ruff N, Newton FC. Comparison of accuracy of 64-slice cardiovascular computed tomography with coronary angiography in patients with suspected coronary artery disease. Am J Cardiol (2006) 97:173–174.[CrossRef][Web of Science][Medline]
  28. Ong TK, Chin SP, Liew CK, Chan WL, Seyfarth MT, Liew HB, Rapaee A, Fong YY, Ang CK, Sim KH. Accuracy of 64-row multidetector computed tomography in detecting coronary artery disease in 134 symptomatic patients: influence of calcification. Am Heart J (2006) 151:1323. e1321-1326.
  29. Schroeder S, Achenbach S, Bengel F, Burgstahler C, Cademartiri F, de Feyter P, George R, Kaufmann P, Kopp AF, Knuuti J, Ropers D, Schuijf J, Tops LF, Bax JJ. Cardiac computed tomography: indications, applications, limitations, and training requirements: report of a Writing Group deployed by the Working Group Nuclear Cardiology and Cardiac CT of the European Society of Cardiology and the European Council of Nuclear Cardiology. Eur Heart J (2008) 29:531–556.[Abstract/Free Full Text]
  30. Maier W, Abay M, Cook S, Togni M, Zeiher A, Meier B. The 2002 European registry of cardiac catheter interventions. Int J Cardiol (2006) 113:299–304.[CrossRef][Web of Science][Medline]
  31. Rozanski A, Diamond GA, Berman D, Forrester JS, Morris D, Swan HJ. The declining specificity of exercise radionuclide ventriculography. N Engl J Med (1983) 309:518–522.[Abstract]
  32. Husmann L, Schepis T, Scheffel H, Gaemperli O, Leschka S, Valenta I, Koepfli P, Desbiolles L, Stolzmann P, Marincek B, Alkadhi H, Kaufmann PA. Comparison of diagnostic accuracy of 64-slice computed tomography coronary angiography in patients with low, intermediate, and high cardiovascular risk. Acad Radiol (2008) 15:452–461.[CrossRef][Web of Science][Medline]
  33. Wintersperger BJ, Nikolaou K, von Ziegler F, Johnson T, Rist C, Leber A, Flohr T, Knez A, Reiser MF, Becker CR. Image quality, motion artifacts, and reconstruction timing of 64-slice coronary computed tomography angiography with 0. 33 sec rotation speed. Invest Radiol (2006) 41:436–442.[CrossRef][Web of Science][Medline]
  34. Schepis T, Gaemperli O, Koepfli P, Valenta I, Strobel K, Brunner A, Leschka S, Desbiolles L, Husmann L, Alkadhi H, Kaufmann PA. Comparison of 64-slice CT with gated SPECT for evaluation of left ventricular function. J Nucl Med (2006) 47:1288–1294.[Abstract/Free Full Text]

Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?

Related articles in EHJ:

Non-invasive CT coronary angiography: can high diagnostic image quality be achieved with less radiation exposure?
Axel Schmermund, Bernd Nowak, and Thomas Voigtländer
EHJ 2008 29: 2955-2956. [Extract] [FREE Full Text]  



This article has been cited by other articles:


Home page
Eur Heart JHome page
S. Achenbach, M. Marwan, D. Ropers, T. Schepis, T. Pflederer, K. Anders, A. Kuettner, W. G. Daniel, M. Uder, and M. M. Lell
Coronary computed tomography angiography with a consistent dose below 1 mSv using prospectively electrocardiogram-triggered high-pitch spiral acquisition
Eur. Heart J., November 5, 2009; (2009) ehp470v1.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
B A Herzog, C A Wyss, L Husmann, O Gaemperli, I Valenta, V Treyer, U Landmesser, and P A Kaufmann
First head-to-head comparison of effective radiation dose from low-dose 64-slice CT with prospective ECG-triggering versus invasive coronary angiography
Heart, October 15, 2009; 95(20): 1656 - 1661.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
J M van Werkhoven, O Gaemperli, J D Schuijf, J W Jukema, L J Kroft, S Leschka, H Alkadhi, I Valenta, G Pundziute, A de Roos, et al.
Multislice computed tomography coronary angiography for risk stratification in patients with an intermediate pretest likelihood
Heart, October 1, 2009; 95(19): 1607 - 1611.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
P. Schoenhagen, E. M. Tuzcu, S. R. Kapadia, M. Y. Desai, and L. G. Svensson
Three-dimensional imaging of the aortic valve and aortic root with computed tomography: new standards in an era of transcatheter valve repair/implantation
Eur. Heart J., September 1, 2009; 30(17): 2079 - 2086.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
G. Pontone, D. Andreini, A. L. Bartorelli, S. Cortinovis, S. Mushtaq, E. Bertella, A. Annoni, A. Formenti, E. Nobili, D. Trabattoni, et al.
Diagnostic accuracy of coronary computed tomography angiography: a comparison between prospective and retrospective electrocardiogram triggering.
J. Am. Coll. Cardiol., July 21, 2009; 54(4): 346 - 355.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
W. P. Shuman, K. R. Branch, J. M. May, L. M. Mitsumori, J. N. Strote, B. H. Warren, T. J. Dubinsky, D. W. Lockhart, and J. H. Caldwell
Whole-Chest 64-MDCT of Emergency Department Patients with Nonspecific Chest Pain: Radiation Dose and Coronary Artery Image Quality with Prospective ECG Triggering Versus Retrospective ECG Gating
Am. J. Roentgenol., June 1, 2009; 192(6): 1662 - 1667.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
W. B. Meijboom, M. F.L. Meijs, J. D. Schuijf, M. J. Cramer, N. R. Mollet, C. A.G. van Mieghem, K. Nieman, J. M. van Werkhoven, G. Pundziute, A. C. Weustink, et al.
Reply
J. Am. Coll. Cardiol., May 12, 2009; 53(19): 1825 - 1826.
[Full Text] [PDF]


Home page
JAMAHome page
A. J. Einstein
Radiation Protection of Patients Undergoing Cardiac Computed Tomographic Angiography
JAMA, February 4, 2009; 301(5): 545 - 547.
[Full Text] [PDF]


Home page
Eur Heart JHome page
A. Schmermund, B. Nowak, and T. Voigtlander
Non-invasive CT coronary angiography: can high diagnostic image quality be achieved with less radiation exposure?
Eur. Heart J., December 2, 2008; 29(24): 2955 - 2956.
[Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow All Versions of this Article:
29/24/3037    most recent
ehn485v1
Right arrow E-letters: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Related articles in EHJ
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (15)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Herzog, B. A.
Right arrow Articles by Kaufmann, P. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Herzog, B. A.
Right arrow Articles by Kaufmann, P. A.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?