Copyright © 1999 by the European Society of Cardiology.
Incidence and clinical relevance of coronary calcification detected by electron beam computed tomography in heart transplant recipients
Royal Brompton and Harefield Hospital NHS Trust, London, U.K.
revised July 20, 1998; accepted July 27, 1998
Abstract
Background Patients treated by cardiac transplantation who survive beyond one year are at significant risk from fatal coronary artery disease. The development of coronary artery calcification in these patients is discussed and methods available to detect it are reviewed.
Objectives To assess the clinical importance of coronary artery calcium in heart transplant recipients.
Methods In a cohort of 102 cardiac transplant recipients, electron beam computed tomography was used to measure calcium in the coronary arterial wall 63 days to 9·1 years (median 4·6 years) after transplantation. The results were compared with angiographic findings and with conventional coronary disease risk factors. The patients were followed for a mean of 2·12 years (1·24·02 years) to assess the relationship between these findings and future cardiac events.
Results Forty-one (40·2%) had a stenosis of >24% in one or more major coronary artery at angiography. Forty-six (45%) had a coronary calcium score >0. The absence of calcium had a negative predictive value with respect to angiographic disease in any vessels of 87·5%. Logistic regression revealed that dyslipidaemia, systemic hypertension and organ ischaemic time were significant predictors of calcification. At follow-up, both an abnormal coronary angiogram and coronary calcium were found to be the only significant predictors of late events. Multivariate analysis suggested that the detection of coronary calcium did not offer any additional predictive information over that provided by the angiogram itself.
Conclusion Electron beam computed tomography is well suited to the assessment of calcium in the coronary arteries of heart transplant recipients, although the mechanisms of this calcification remain poorly understood. Calcium is detected more frequently than would be suggested by studies using intravascular ultrasound. It is associated with the presence of angiographic disease, and with some conventional risk factors for coronary disease. At follow-up the presence of coronary calcium was associated with an adverse clinical outcome, as it is in conventional ischaemic heart disease.
Key Words: coronary calcification, cardiac transplan-tation, transplant coronary atherosclerosis, electron beam computed tomography.
f1 Correspondence: Professor Sir Magdi Yacoub, Royal Brompton Hospital and Harefield NHS Trust, Sydney Street, London SW3 6NP, U.K.
References
- Uretsky BF, Kormos LR, Zerbe TR. Cardiac events after heart transplantation: Incidence and predictive value of coronary arteriography. J Heart Lung Transplant. 1992;11:S45S51[Web of Science][Medline]
- Gao SZ, Alderman EL, Schroeder JS, Silverman JF, Hunt SA. Accelerated coronary vascular disease in heart transplant patients: coronary arteriographic findings. J Am Coll Cardiol. 1988;12:334340[Abstract]
- Davies MJ, Woolf N. Atherosclerosis: what is it and why does it occur. Br Heart J. 1993;69 (Suppl):S3S11
- Salomon RN, Hughes CC, Schoen FJ, Payne DD, Pober JS, Libby P. Human coronary transplantation associated arteriosclerosis: evidence for a chronic immune reaction to activated graft endothelial cells. Am J Pathol. 1991;138:791798[Abstract]
- Billingham ME. Histopathology of graft coronary disease. J Heart Transplant. 1992;11:S38S44
- Johnson DE, Alderman EL, Schroeder JS. Transplant coronary artery disease: histopathological correlations with angiographic morphology. J Am Coll Cardiol. 1991;17:449457[Abstract]
- Arbustini E, Roberts WC. Morphologic observations in the epicardial coronary arteries in their surroundings late after cardiac transplantation. Am J Cardiol. 1996;78:814820[CrossRef][Web of Science][Medline]
- St Goar FG, Pinto FJ, Alderman EL, Valantine HA. Intracoronary ultrasound in cardiac transplant recipients. In vivo evidence of angiographically silent intimal thickening. Circulation. 1992;85:979987
[Abstract/Free Full Text] - Anderson TJ, Meredith IT, Uehata A. Functional significance of intimal thickening as detected by intravascular ultrasound early and late after cardiac transplantation. Circulation. 1993;88:10931100
[Abstract/Free Full Text] - Rickenbacher PR, Pinto FJ, Chenzbraun A. Incidence and severity of transplant coronary disease early and up to 15 years after transplantation as detected by intravascular ultrasound. J Am Coll Cardiol. 1995;25:171177[Abstract]
- Tuzcu EM, DeFranco AC, Goormastic M. Dichotomous pattern of coronary atherosclerosis 1 to 9 years after transplantation: insights from systematic intravascular ultrasound imaging. J Am Coll Cardiol. 1996;27:839846[Abstract]
- Smart FW, Ballantyne CM, Cocanougher B. Insensitivity of noninvasive tests to detect coronary artery vasculopathy after heart transplant. Am J Cardiol. 1991;67:243247[CrossRef][Web of Science][Medline]
- Spes CH, Mudra H, Schnaack SD. Dobutamine stress echocardiography for noninvasive diagnosis of cardiac allograft vasculopathy: a comparison with angiography and intravascular ultrasound. Am J Cardiol. 1996;78:168174[Web of Science][Medline]
- Derumeaux G, Redonnet M, Mouton-Schleifer D. Dobutamine stress echocardiography in orthotopic heart transplant recipients. J Am Coll Cardiol. 1995;25:16651672[Abstract]
- Mehra MR, Ventura HO, Chambers R. Predictive model to assess risk for cardiac allograft vasculopathy: an intra-vascular ultrasound model. J Am Coll Cardiol. 1995;26:15371544[Abstract]
- Ikeda T, Shirasawa T, Esaki Y, Yoshiki S, Hirokawa K. Osteopontin mRNA is expressed by smooth muscle-derived foam cells in human atherosclerotic lesions of the aorta. J Clin Invest. 1993;92:28142820[Web of Science][Medline]
- Fitzpatrick A, Severson A, Edwards WD, Ingram RT. Diffuse calcification in human coronary arteries. J Clin Invest. 1994;94:15971604[Web of Science][Medline]
- Mahaisavariya P, Detrano R, Kang X. Quantitation of in vitro coronary artery calcium using ultrafast computed tomography. Cathet Cardiovasc Diagn. 1994;32:387393[Web of Science][Medline]
- Detrano R, Kang X, Mahaisavariya P. Accuracy of quantifying coronary hydroxyapatite with electron beam tomography. Invest Radiol. 1994;29:733738[CrossRef][Web of Science][Medline]
- Mautner GC, Mautner SL, Froehlich J. Coronary artery calcification: assessment with electron beam CT and histomorphometric correlation. Radiology. 1994;192:619623
[Abstract/Free Full Text] - Detrano R, Schwendener C, Doherty T, Secci A. Coronary calcium results predict coronary heart disease deaths in high risk asymptomatic adults. J Am Coll Cardiol. 1997;29:128A
- Pflugfelder PW, Boughner DR, Rudas L, Kostuk WJ. Enhanced detection of cardiac allograft arterial disease with intracoronary ultrasonographic imaging. Am Heart J. 1993;125:15831591[CrossRef][Web of Science][Medline]
- Mayer EL, DeFranco AC, Hobbs RE. Safety of intravascular ultrasound in cardiac transplant recipients (Abstr). J Am Coll Cardiol. 1997;29:20A
- Barbir M, Bowker T, Ludman PF, Mitchell AG, Wood D, Yacoub M. Ultrafast computed tomography scanning for detection of coronary disease in cardiac transplant recipients. Am J Cardiol. 1994;74:941944[CrossRef][Web of Science][Medline]
- Barbir M, Lazem F, Bowker T. Determinants of transplant related coronary calcification detected by ultrafast computed tomography scanning. Am J Cardiol. 1997;79:16061609[CrossRef][Web of Science][Medline]
- Lazem F, Barbir M, Banner N, Ludman PF, Mitchell A, Yacoub M. Coronary calcification detected by ultrafast computed tomography is a predictor of cardiac events in heart transplant recipients. Transplant Proc. 1997;29:572575[CrossRef][Web of Science][Medline]
This article has been cited by other articles:
![]() |
G. Melina, P. Horkaew, M. Amrani, M. B. Rubens, M. H. Yacoub, and G.-Z. Yang Three-dimensional in vivo characterization of calcification in native valves and in Freestyle versus homograft aortic valves J. Thorac. Cardiovasc. Surg., July 1, 2005; 130(1): 41 - 47. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Dandel, M. Hummel, J. Muller, E. Wellnhofer, R. Meyer, N. Solowjowa, R. Ewert, and R. Hetzer Reliability of Tissue Doppler Wall Motion Monitoring After Heart Transplantation for Replacement of Invasive Routine Screenings by Optimally Timed Cardiac Biopsies and Catheterizations Circulation, September 18, 2001; 104 (2009): I-184 - I-191. [Abstract] [Full Text] [PDF] |
||||
![]() |
H.M. Colhoun Coronary calcification in heart transplants. Eur. Heart J., October 1, 1999; 20(20): 1515 - 1515. [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||