Skip Navigation

European Heart Journal 2000 21(6):466-474; doi:10.1053/euhj.1999.1871
Copyright © 2000 by the European Society of Cardiology.
This Article
Right arrow Abstract Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow E-letters: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (12)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Piek, J.J
Right arrow Articles by Serruys, P.W
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Piek, J.J
Right arrow Articles by Serruys, P.W
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Angiographical and Doppler flow-derived parameters for assessment of coronary lesion severity and its relation to the result of exercise electrocardiography

J.J Pieka,f1, E Boersmab, C di Marioc, E Schroederd, C Vrintse, P Probstf, B de Bruyneg, C Haneth, E Flecki, M Haudej, E Vernak, V Voudrisl, H Geschwindm, H Emanuelssonn, V Mühlbergero, H.O Peelsp and P.W Serruysb

a Academical Medical Center, Amsterdam, The Netherlands
b Thoraxcenter, Rotterdam, The Netherlands
c Centro Curore Columbus, Milano, Italy
d Clinique Universitaire de Mont-Godinne, Yvoir, Belgium
e Universitair Ziekenhuis, Antwerp, Belgium
f Kardiologische Universitätsklinik, Wien, Austria
g Onze Lieve Vrouwe Kliniek, Aalst, Belgium
h Clinique Universitaires de Saint-Luc, Brussels, Belgium
i Deutsches Herzzentrum, Berlin, Germany
j Universitåt Essen, Essen, Germany
k Ospedale di Circolo, Varese, Italy
l Onassis Cardiac Surgery Center, Athens, Greece
m Université Paris XII Val de Marne, La Creteil, France
n Sahlgrenska Hospital, Göteborg, Sweden
o Universitätsklinik fur Innere Medizin, Innsbrück, Austria
p Academisch Ziekenhuis, Groningen, The Netherlands

revised July 9, 1999; accepted July 22, 1999

Abstract

Aims Evaluation of angiographical and intracoronary Doppler-derived parameters of coronary stenosis severity.

Methods and Results A total of 225 patients with one-vessel disease were studied before PTCA and at 6 months follow-up. Exercise electrocardiography was performed to document presence (n=157) or absence (n=138) of an ST segment shift (≥0·1mV). Intracoronary blood flow velocity analysis was performed to determine the proximal/distal flow velocity ratio, the distal diastolic/systolic flow velocity ratio and coronary flow velocity reserve. Receiver operator characteristic curves were calculated to assess the predictive value of these variables compared with the exercise test. The distal coronary flow velocity reserve demonstrated the best linear correlation for both percentage diameter stenosis and minimum lumen diameter (r=0·67 and r=0·66;P<0·01), compared to the diastolic/systolic flow velocity ratio (r=0·19 and r=0·14;P<0·01) and the proximal/distal flow velocity ratio (r=0·03 and r=0·07; not significant). The areas under the curve were 0·84±0·02; 0·82±0·03 and 0·83±0·03 for diameter stenosis, minimum lumen diameter and coronary flow velocity reserve, respectively. Logistic regression analysis revealed that the percentage diameter stenosis or minimum lumen diameter and coronary flow velocity reserve were independent predictors for the result of stress testing.

Conclusions The distal coronary flow velocity reserve is the best intracoronary Doppler parameter for evaluation of coronary narrowings. Angiographical estimates of coronary lesion severity and distal coronary flow velocity reserve are good and independent predictors for the assessment of functional severity of coronary stenosis, emphasizing the complementary role of these parameters for clinical decision making.

Key Words: Angiography, coronary stenosis, intracoronary Doppler, exercise electrocardiography

f1 Correspondence: Jan J. Piek, MD, Department of Cardiology, B2-108, Academic Medical Center, Meibergdreef 9, 1105 AZ Amsterdam, The Netherlands.

References

  1. Brown BG, Bolson EL, Dodge HT. Arteriographic assessment of coronary atherosclerosis: review of current methods, their limitations, and clinical applications. Arteriosclerosis. 1982;2:2–15[Abstract/Free Full Text]
  2. Reiber JHC, Kooijman CJ, Slager CJ. Coronary artery dimensions from cineangiograms-methodology and validation of a computer-assisted analysis procedure. IEEE. 1984;MI-3:131–141
  3. Keane D, Haase J, Slager CJ. Comparative validation of quantitative coronary angiography systems: results implications from a multicenter study using a standardized approach. Circulation. 1995;91:2174–2183[Abstract/Free Full Text]
  4. White CW, Wright CB, Doty DB. Does visual interpretation of the coronary arteriogram predict the physiologic importance of coronary stenosis? N Engl J Med. 1984;310:819–824[Abstract]
  5. Goldstein RA, Kirkeeide RL, Demer LL. Relation between geometric dimensions of coronary artery stenoses and myocardial perfusion reserve in man. J Clin Invest. 1987;79:1473–1478[Web of Science][Medline]
  6. Folland ED, Vogel RA, Hartigan P. Relation between coronary artery stenosis assessed by visual, caliper, and computer methods and exercise capacity in patients with single-vessel coronary artery disease. Circulation. 1994;89:2005–2014[Abstract/Free Full Text]
  7. Uren NG, Melin JA, De Bruyne B, Wijns W, Baudhuin T, Camici PG. Relation between myocardial blood flow and the severity of coronary-artery stenosis. N Engl J Med. 1994;330:1782–1788[Abstract/Free Full Text]
  8. Ofili EO, Labovitz AJ, Kern MJ. Coronary flow velocity dynamics in normal and diseased arteries. Am J Cardiol. 1993;71:3D–9D[CrossRef][Medline]
  9. Segal J. Applications of coronary flow velocity during angioplasty and other coronary interventional procedures. Am J Cardiol. 1993;71:17D–25D[CrossRef][Medline]
  10. Serruys PW, di Mario C, Piek JJ. Prognostic value of intracoronary flow velocity and diameter stenosis in assessing the short- and long-term outcomes of coronary balloon angioplasty: The D.E.B.A.T.E. Study (Doppler Endpoints Balloon Angioplasty Trial Europe). Circulation. 1997;96:3369–3377[Abstract/Free Full Text]
  11. Doucette JW, Corl PD, Payne HM. Validation of a Doppler guide wire for intravascular measurement of coronary artery flow velocity. Circulation. 1992;85:1899–1911[Abstract/Free Full Text]
  12. Di Mario C, Haase J, den Boer A, Reiber JHC, Serruys PW. Edge detection versus densitometry in the quantitative assessment of stenosis phantoms: an in vivo comparison in porcine coronary arteries. Am Heart J. 1992;124:1181–1189[CrossRef][Web of Science][Medline]
  13. Di Mario C, Krams R, Gil R, Serruys PW. Slope of the instantaneous hyperemic diastolic coronary flow velocity-pressure relation. Circulation. 1994;90:1215–1224[Abstract/Free Full Text]
  14. Serruys PW, Di Mario C, Meneveau N. Intracoronary pressure and flow velocity with sensor-tip guidewires: a new methodologic approach for assessment of coronary hemodynamics before and after coronary interventions. Am J Cardiol. 1993;71:41D–53D[CrossRef][Medline]
  15. De Bruyne B, Pijls NHJ, Paulus WJ, Vantrimpont PJ, Sys SU, Heyndrickx GR. Transstenotic coronary pressure gradient measurements in humans: In vitro and in vivo evaluation of a new pressure monitoring angioplasty guide wire. J Am Coll Cardiol. 1993;22:119–126[Abstract]
  16. Donohue TJ, Kern MJ, Aguirre FV. Assessing the hemodynamic significance of coronary artery stenoses: Analysis of translesional pressure-flow velocity relations in patients. J Am Coll Cardiol. 1993;22:449–458[Abstract]
  17. Pijls NHJ, De Bruyne B, Peels K. Measurement of fractional flow reserve to assess the functional severity of coronary-artery stenoses. N Engl J Med. 1996;334:1703–1708[Abstract/Free Full Text]
  18. Ofili EO, Kern MJ, St Vrain JA. Differential characterization of blood flow, velocity, and vascular resistance between proximal and distal normal epicardial human coronary arteries: analysis by intracoronary Doppler spectral flow velocity. Am Heart J. 1995;130:37–46[CrossRef][Web of Science][Medline]
  19. Bartunek J, Sys SU, Heyndrickx GR, Pijls NHJ, De Bruyne B. Quantitative coronary angiography in predicting functional significance of stenoses in unselected patient cohort. J Am Coll Cardiol. 1995;26:328–334[Abstract]
  20. Kern MJ, Dupouy P, Drury JH. Role of coronary artery lumen enlargement in improving coronary blood flow after balloon angioplasty and stenting: a combined intravascular ultrasound Doppler flow and imaging study. J Am Coll Cardiol. 1997;29:1520–1527[Abstract]
  21. Heller LI, Cates C, Popma JJ. Intracoronary Doppler assessment of moderate coronary artery disease: comparison with 201TI imaging and coronary angiography. Circulation. 1997;96:484–490[Abstract/Free Full Text]
  22. Joye JD, Schulman DS, Lasorda D, Farah T, Donohue BC, Reichek N. Intracoronary Doppler guide wire versus stress single-photon emission computed tomography thallium-201 imaging in assessment of intermediate coronary stenoses. J Am Coll Cardiol. 1994;24:940–947[Abstract]
  23. Miller DD, Donohue TJ, Younis LT. Correlation of pharmacological 99mTc-sestamibi myocardial perfusion imaging with poststenotic coronary flow reserve in patients with angiographically intermediate coronary artery stenoses. Circulation. 1994;89:2150–2160[Abstract/Free Full Text]
  24. Deychak YA, Segal J, Reiner JS. Doppler guide wire flow-velocity indexes measured distal to coronary stenoses associated with reversible thallium perfusion defects. Am Heart J. 1995;129:219–227[CrossRef][Web of Science][Medline]
  25. Melin JA, Piret LJ, Vanbutsele RJM. Diagnostic value of exercise electrocardiography and thallium myocardial scintigraphy in patients without previous myocardial infarction: a bayesian approach. Circulation. 1981;63:1019–1024[Free Full Text]
  26. Verberne HJ, Piek JJ, van Liebergen RAM, Koch KT, Schroeder-Tanka JM, van Royen EA. Functional assessment of coronary artery stensosis by Doppler derived absolute and relative coronary blood flow velocity reserve in comparison with99mTc MIBI SPECT. Heart. 1999;82:509–514[Abstract/Free Full Text]
  27. De Bruyne B, Bartunek J, Sys SU, Pijls NHJ, Heyndrickx GR, Wijns W. Simultaneous coronary pressure and flow velocity measurements in humans. Feasibility, reproducibility, and hemodynamic dependence of coronary flow velocity reserve, hyperemic flow versus pressure slope index, and fractional flow reserve. Circulation. 1996;94:1842–1849[Abstract/Free Full Text]
  28. Baumgart D, Haude M, Görge G. Improved assessment of coronary stenosis severity using the relative flow velocity reserve. Circulation. 1998;98:40–46[Abstract/Free Full Text]
  29. van Liebergen RAM, Piek JJ, Koch KT, de Winter RJ, Lie KI. Immediate and long-term effect of balloon angioplasty or stent implantation on the absolute and relative coronary blood flow velocity reserve. Circulation. 1998;98:2133–2140[Abstract/Free Full Text]
  30. Bache RJ. Effects of calcium entry blockade on myocardial blood flow. Circulation. 1989;80:IV-40–IV-46
  31. Schwartz JS, Bache RJ. Pharmacologic vasodilators in the coronary circulation. Circulation. 1987;75:I-162–I-167
  32. Rozenman Y, Gilon D, Zelingher J, Lotan C, Mosseri M, Geist M. One-stage coronary angiography and angioplasty. Am J Cardiol. 1995;75:30–33[CrossRef][Web of Science][Medline]
  33. Bech GJW, De Bruyne B, Pijls NHJ. Comparison of deferral versus performance of PTCA based upon fractional flow reserve: the DEFER Study. J Am Coll Cardiol. 1999;33:89A
  34. Serruys PW, de Bruyne B, de Sousa JE. Debate II: A randomized study to evaluate the need for additional stenting after guided balloon angioplasty (provisional stenting) (Abstr). Eur Heart J. 1998;19:
  35. Di Mario C, Moses J, Muramatsu T. Multicentre randomized comparison of primary stenting vs. balloon angioplasty optimized by QCA and intracoronary Doppler: procedural results in 580 patients (Abstr). Eur Heart J. 1998;19:567
  36. Steg PG. A multicentre randomized trial comparing systematic stenting to provisional stenting guided by angiography and coronary velocity reserve: final results (Abstr). Eur Heart J. 1998;19:

Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Phil Trans R Soc AHome page
J. Spaan, C. Kolyva, J. van den Wijngaard, R. ter Wee, P. van Horssen, J. Piek, and M. Siebes
Coronary structure and perfusion in health and disease
Phil Trans R Soc A, September 13, 2008; 366(1878): 3137 - 3153.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
M. J. Kern, A. Lerman, J.-W. Bech, B. De Bruyne, E. Eeckhout, W. F. Fearon, S. T. Higano, M. J. Lim, M. Meuwissen, J. J. Piek, et al.
Physiological Assessment of Coronary Artery Disease in the Cardiac Catheterization Laboratory: A Scientific Statement From the American Heart Association Committee on Diagnostic and Interventional Cardiac Catheterization, Council on Clinical Cardiology
Circulation, September 19, 2006; 114(12): 1321 - 1341.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
T. Nishida, C. Di Mario, M.J. Kern, T.J. Anderson, I. Moussa, R. Bonan, T. Muramatsu, A.C. Jain, J. Suarez de Lezo, S.Y. Cho, et al.
Impact of final coronary flow velocity reserve on late outcome following stent implantation
Eur. Heart J., February 2, 2002; 23(4): 331 - 340.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
R. Seabra-Gomes
Functional assessment of coronary stenosis: it does make sense, but why don't I do it more often?
Eur. Heart J., March 2, 2000; 21(6): 422 - 424.
[PDF]


This Article
Right arrow Abstract Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow E-letters: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (12)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Piek, J.J
Right arrow Articles by Serruys, P.W
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Piek, J.J
Right arrow Articles by Serruys, P.W
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?