Skip Navigation

European Heart Journal 2000 21(8):654-661; doi:10.1053/euhj.1999.1853
Copyright © 2000 by the European Society of Cardiology.
This Article
Right arrow Abstract Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow E-letters: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (6)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Peters, R.J.G
Right arrow Articles by Serruys, P.W
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Peters, R.J.G
Right arrow Articles by Serruys, P.W
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Videodensitometric quantitative angiography after coronary balloon angioplasty, compared to edge-detection quantitative angiography and intracoronary ultrasound imaging

R.J.G Petersa,f1, W.E.M Koka, G Pasterkampb, C Von Birgelenc, M Prinsd and P.W Serruysc

a Academic Medical Center, Department of Cardiology
b InterUniversity Cardiology Institute of the Netherlands, Utrecht
c Thoraxcenter, Division of Cardiology, Erasmus University, Rotterdam, The Netherlands
d Department of Clinical Epidemiology, University of Amsterdam, Amsterdam

revised August 3, 1999; accepted August 4, 1999

Abstract

Aims To assess the value of videodensitometric quantification of the coronary lumen after angioplasty by comparison to two other techniques of coronary artery lumen quantification.

Methods and Results Videodensitometric quantitative angiography, edge detection quantitative angiography and 30MHz intracoronary ultrasound imaging were performed after successful balloon angioplasty in 161 patients. Lumen cross-sectional areas were mean (SD) 2·82 (1·15)mm2for edge detection quantitative angiography, 3·67 (1·5)mm2for videodensitometric quantitative angiography and 5·32 (1·75)mm2for intracoronary ultrasound imaging (P<0·001). The correlation between intracoronary ultrasound imaging and videodensitometric quantitative angiography (r=0·44) was almost similar to that of intracoronary ultrasound imaging and edge detection quantitative angiography (r=0·47). The correlation between the three techniques was not significantly influenced by the presence of ruptures and dissections on intracoronary ultrasound imaging. The absence of calcifications improved the correlation between videodensitometry and intracoronary ultrasound imaging.

Conclusions The luminal dimensions as measured by videodensitometric quantitative angiography matched intracoronary ultrasound imaging derived dimensions more closely than edge detection quantitative angiography. Videodensitometric quantitative angiography represents an on-line alternative to intracoronary ultrasound imaging for quantitative analysis regardless of the degree of vessel damage.

Key Words: Videodensitometry, quantitative coronary angiography, intravascular ultrasound imaging, balloon angioplasty

f1 Correspondence: Ron J. G. Peters, MD, Department of Cardiology, Room F3-236, Academic Medical Center, Meibergdreef 9, 1105 AZ, Amsterdam, The Netherlands.

References

  1. Serruys PW, Reiber JHC, Wijns W. Assessment of percutaneous transluminal coronary angioplasty by quantitative coronary angiography: diameter versus densitometric area measurements. Am J Cardiol. 1984;54:482–488[CrossRef][Web of Science][Medline]
  2. Nichols AB, Gabrieli CFO, Fenoglio JJ Jr. Quantification of relative coronary arterial stenosis by cinevideodensitometric analysis of coronary angiograms. Circulation. 1984;69:512–522[Abstract/Free Full Text]
  3. Tobis J, Nalcioglu O, Johnston WD. Videodensitometric determination of minimum coronary artery luminal diameter before and after angioplasty. Am J Cardiol. 1987;59:38–44[CrossRef][Web of Science][Medline]
  4. Ozaki Y, Violaris AG, Kobayashi T. Comparison of coronary luminal quantification obtained from intracoronary ultrasound and both geometric and videodensitometric quantitative angiography before and after balloon angioplasty and directional atherectomy. Circulation. 1997;96:491–499[Abstract/Free Full Text]
  5. Peters RJG, Kok WEM, Di Mario C. Prediction of restenosis following coronary balloon angioplasty: results of PICTURE (post intra coronary treatment ultrasound result evaluation), a prospective multicenter intracoronary ultrasound imaging study. Circulation. 1997;95:2254–2261[Abstract/Free Full Text]
  6. Serruys PW, Luijten HE, Beatt KJ. Incidence of restenosis after successful coronary angioplasty: a time related phenomenon. A quantitative angiographic study in 342 consecutive patients at 1, 2, 3 and 4 months. Circulation. 1988;77:361–371[Abstract/Free Full Text]
  7. Reiber JHC, Serruys PW, Kooyman CJ. Approaches toward standardization in acquisition and quantitation of arterial dimensions from cineangiograms. Reiber JHC, Serruys PW. State of the art in quantitative coronary angiography. Dordrecht: Martinus Nijhoff; 1986. p. 145–155
  8. Strauss BH, Escaned J, Di Mario C. Technical considerations and practical limitations in the use of quantitative angiography during percutaneous coronary recanalization. Prog Cardiovasc Dis. 1994;36:343–363[CrossRef][Web of Science][Medline]
  9. Haase J, Di Mario C, Slager CJ. In-vivo validation of on-line and off-line geometric coronary measurements using insertion of stenosis phantoms in porcine coronary arteries. Cathet Cardiovasc Diagn. 1992;27:16–27[Web of Science][Medline]
  10. Di Mario C, Haase J, den Boer A. Edge detection versus densitometry in the quantitative assessment of stenosis phantoms: an in vitro comparison in porcine coronary arteries. J Am Heart. 1992;124:1181–1189
  11. Haase J, Escaned J, van Swijndrecht EM. Experimental validation of geometric and densitometric coronary measurements on the new generation cardiovascular angiography analysis system. Cathet Cardiovasc Diagn. 1993;30:104–114[Web of Science][Medline]
  12. Haase J, Keane D, Di Mario C. How reliable are geometric coronary measurements? In vitro and in vivo validation of digital and cinefilm based quantitative coronary analysis systems. Serruys PW, Foley DP, de Feyter PJ. Quantitative Coronary Angiography in Clinical Practice. Dordrecht: Kluwer Academic Publishers; 1994. p. 27–49
  13. Wenguang L, Gussenhoven WJ, Bosch JG. A computer-aided analysis system for the quantitative assessment of intravascular ultrasound images. Computers in Cardiology. 1990;:333–336
  14. Popma JJ, Mintz GS, Satler LF. Clinical and angiographic outcome after directional coronary atherectomy. Am J Cardiol. 1993;72:55E–64E[CrossRef][Medline]
  15. Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1:307–310[CrossRef][Web of Science][Medline]
  16. Peters RJG, Kok WEM, van der Wal AC. In vitro validation of intracoronary ultrasound imaging after balloon angioplasty of coronary stenoses. Ultrasound in Med and Biol. 1996;22:999–1005
  17. Di Mario C, Gorge G, Peters R. On behalf of the Study group on Intracoronary Imaging of the Working Group of Coronary Circulation and of the subgroup on Intravascular Ultrasound of the Working Group of Echocardiography of the European Society of Cardiology. Clinical application and image interpretation in intracoronary ultrasound. Eur Heart J. 1998;19:207–229[Free Full Text]
  18. Nissen SE, Gurley JC, Grines CL. Intravascular ultrasound assessment of lumen size and wall morphology in normal subjects and patients with coronary artery disease. Circulation. 1991;84:1087–1099[Abstract/Free Full Text]
  19. St Goar FG, Pinto FJ, Alderman EL. Detection of coronary atherosclerosis in young adult hearts using intravascular ultrasound. Circulation. 1992;86:756–763[Abstract/Free Full Text]
  20. Kearney PP, Starkey IR, Sutherland GR. Intracoronary ultrasound: current state of the art. Br Heart J (Suppl). 1995;73:16–25
  21. Haase J, Ozaki Y, Di Mario C. Can coronary ultrasound correctly assess the luminal dimensions of coronary lesions? A comparison with quantitative angiography. Eur Heart J. 1995;16:112–119[Web of Science][Medline]
  22. Nissen SE, Gurley JC, Grines CL. Intravascular ultrasound assessment oflumen size and wall morphology in normal subjects and patients with coronary artery disease. Circulation. 1991;84:1087–1099
  23. DeScheerder I, DeMan F, Herregods MC. Intravascular ultrasound versus angiography for measurements of luminal diameters in normal and diseased coronary arteries. Am Heart J. 1994;127:243–251[CrossRef][Web of Science][Medline]
  24. St Goar FG, Pinto FJ, Alderman EL. Intravascular ultrasound imaging of angiographically normal coronary arteries: an in vivo comparison with quantitative angiography. J Am Coll Cardiol. 1991;18:952–958[Abstract]
  25. Mintz GS, Potkin BN, Keren G. Intravascular ultrasound evaluation of the effect of rotational atherectomy in obstructive atherosclerotic coronary artery disease. Circulation. 1992;86:1383–1393[Abstract/Free Full Text]
  26. Davidson CJ, Sheikh KH, Kisslo KB. Intracoronary ultrasound evaluation of interventional technologies. Am J Cardiol. 1991;68:1305–1309[CrossRef][Web of Science][Medline]
  27. Laskey WK, Brady ST, Kussmaul WG. Intravascular ultrasonographic assessment of the results of coronary stenting. Am Heart J. 1993;125:1576–1583[CrossRef][Web of Science][Medline]
  28. Von Birgelen C, Kutryk MJB, Gil R. Quantification of the minimal luminal cross-sectional area after coronary stenting by two- and three dimensional intravascular ultrasound versus edge detection and videodensitometry. Am J Cardiol. 1996;78:520–525[CrossRef][Web of Science][Medline]
  29. von Birgelen C, Umans V, Di Mario C. Mechanism of high-speed rotational atherectomy and adjunctive balloon angioplasty revisited by quantitative angiography: edge detection versus videodensitometry. Am Heart J. 1995;130:405–412[CrossRef][Web of Science][Medline]
  30. Ryan TJ, Faxon DP, Gunnar RM. Guidelines for percutaneous transluminal coronary angioplasty: A report of the American College of Cardiology/American Heart Association Task Force on Assessment of Diagnostic and Therapeutic Cardiovascular Procedures (Subcommittee on Percutaneous Transluminal Coronary Angioplasty). J Am Coll Cardiol. 1988;12:529–545[Web of Science][Medline]

Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
CirculationHome page
A. J. Flammer, F. Hermann, I. Sudano, L. Spieker, M. Hermann, K. A. Cooper, M. Serafini, T. F. Luscher, F. Ruschitzka, G. Noll, et al.
Dark Chocolate Improves Coronary Vasomotion and Reduces Platelet Reactivity
Circulation, November 20, 2007; 116(21): 2376 - 2382.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
F. Alfonso
Videodensitometric vs edge-detection quantitative angiography. Insights from intravascular ultrasound imaging
Eur. Heart J., April 2, 2000; 21(8): 604 - 607.
[PDF]


This Article
Right arrow Abstract Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow E-letters: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (6)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Peters, R.J.G
Right arrow Articles by Serruys, P.W
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Peters, R.J.G
Right arrow Articles by Serruys, P.W
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?