Skip Navigation

European Heart Journal 2001 22(8):669-675; doi:10.1053/euhj.2000.2283
Copyright © 2001 by the European Society of Cardiology.
This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (15)
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Wardeh, A.J
Right arrow Articles by Serruys, P.W
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wardeh, A.J
Right arrow Articles by Serruys, P.W
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Clinical and angiographical follow-up after implantation of a 6–12µCi radioactive stent in patients with coronary artery disease

A.J Wardeha, A.H.M Knooka, I.P Kaya, M Sabatéa, V.L.M.A Coenb, D.P Foleya, J.N Hamburgera, P.C Levendagb, W.J van der Giessena and P.W Serruysa,f1

a Thoraxcenter Rotterdam, University Hospital Rotterdam, Dijkzigt, Rotterdam, The Netherlands
b The Daniel den Hoed Cancer Center, Rotterdam, The Netherlands

revised May 15, 2000; accepted May 22, 2000

Abstract

Aims This study is the contribution by the Thoraxcenter, Rotterdam, to the European32P Dose Response Trial, a non-randomized multicentre trial to evaluate the safety and efficacy of the radioactive IsostentTM in patients with single coronary artery disease.

Methods and Results The radioactivity of the stent at implantation was 6–12µCi. All patients received aspirin indefinitely and either ticlopidine or clopidogrel for 3 months. Quantitative coronary angiography measurements of both the stent area and the target lesion (stent area and up to 5mm proximal and distal to the stent edges) were performed pre- and post-procedure and at the 5-month follow-up. Forty-two radioactive stents were implanted in 40 patients. Treated vessels were the left anterior descending coronary artery (n=20), right coronary artery (n=10) or left circumflex artery (n=10). Eight patients received additional non-radioactive stents. Lesion length measured 10±3mm with a reference diameter of 3·07±0·69mm. Minimal lumen diameter increased from 0·98±0·53mm pre-procedure to 2·29±0·52mm (target lesion) and 2·57±0·44mm (stent area) post-procedure. There was one procedural non-Q wave myocardial infarction, due to transient thrombotic closure. Thirty-six patients returned for angiographical follow-up. Two patients had a total occlusion proximal to the radioactive stent. Of the patent vessels, none had in-stent restenosis. Edge restenosis was observed in 44%, occurring predominantly at the proximal edge. Target lesion revascularization was performed in 10 patients and target vessel revascularization in one patient. No additional clinical end-points occurred during follow-up. The minimal lumen diameter at follow-up averaged 1·66±0·71mm (target lesion) and 2·12±0·72 (stent area); therefore late loss was 0·63±0·69 (target lesion) and 0·46±0·76 (stent area), resulting in a late loss index of 0·65±1·15 (target lesion) and 0·30±0·53 (stent area).

Conclusion These results indicate that the use of radioactive stents is safe and feasible, however, the high incidence of edge restenosis makes this technique currently clinically non-applicable.

Key Words: ß-particles, angioplasty, radioisotope, restenosis, stent

f1 Correspondence: Prof. Patrick W. Serruys, MD, PhD, Head of the Department of Interventional Cardiology, Thoraxcenter Bd 406, University Hospital Dijkzigt, Dr. Molewaterplein 40, 3015 GD Rotterdam, The Netherlands.

References

  1. Mintz GS, Popma JJ, Pichard AD. Arterial remodeling after coronary angioplasty: a serial intravascular ultrasound study. Circulation. 1996;94:35–43[Abstract/Free Full Text]
  2. Farb A, Sangiorgi G, Carter AJ. Pathology of acute and chronic coronary stenting in humans. Circulation. 1999;99:44–52[Abstract/Free Full Text]
  3. Wiedermann JG, Marboe C, Amols H, Schwartz A, Weinberger J. Intracoronary irradiation markedly reduces restenosis after balloon angioplasty in a porcine model. J Am Coll Cardiol. 1994;23:1491–1498[Abstract]
  4. Waksman R, Robinson KA, Crocker IR. Intracoronary low-dose beta-irradiation inhibits neointima formation after coronary artery balloon injury in the swine restenosis model. Circulation. 1995;92:3025–3031[Abstract/Free Full Text]
  5. Wiedermann JG, Marboe C, Amols H, Schwartz A, Weinberger J. Intracoronary irradiation markedly reduces neointimal proliferation after balloon angioplasty in swine: persistent benefit at 6-month follow-up. J Am Coll Cardiol. 1995;25:1451–1456[Abstract]
  6. Liermann D, Bottcher HD, Kollath J. Prophylactic endovascular radiotherapy to prevent intimal hyperplasia after stent implantation in femoropopliteal arteries. Cardiovasc Intervent Radiol. 1994;17:12–16[CrossRef][ISI][Medline]
  7. Carter AJ, Laird JR, Bailey LR. Effects of endovascular radiation from a beta-particle-emitting stent in a porcine coronary restenosis model. A dose-response study. Circulation. 1996;94:2364–2368[Abstract/Free Full Text]
  8. Hehrlein C, Gollan C, Donges K. Low-dose radioactive endovascular stents prevent smooth muscle cell proliferation and neointimal hyperplasia in rabbits. Circulation. 1995;92:1570–1575[Abstract/Free Full Text]
  9. Hehrlein C, Stintz M, Kinscherf R. Pure beta-particle-emitting stents inhibit neointima formation in rabbits. Circulation. 1996;93:641–645[Abstract/Free Full Text]
  10. Carter AJ, Laird JR. Experimental results with endovascular irradiation via a radioactive stent. Int J Radiat Oncol Biol Phys. 1996;36:797–803[CrossRef][ISI][Medline]
  11. Carter AJ, Scott D, Bailey L, Hoopes T, Jones R, Virmani R. Dose-response effects of 32P radioactive stents in an atherosclerotic porcine coronary model. Circulation. 1999;100:1548–1554[Abstract/Free Full Text]
  12. Taylor AJ, Gorman PD, Farb A, Hoopes TG, Virmani R. Long-term coronary vascular response to 32P beta-particle-emitting stents in a canine model. Circulation. 1999;100:2366–2372[Abstract/Free Full Text]
  13. Albiero R, Adamian M, Kobayashi N. Short- and intermediate-term results of (32)P radioactive beta-emitting stent implantation in patients with coronary artery disease: The Milan Dose-Response Study. Circulation. 2000;101:18–26[Abstract/Free Full Text]
  14. Wardeh AJ, Kay IP, Sabate M. beta-Particle-emitting radioactive stent implantation. A safety and feasibility study. Circulation. 1999;100:1684–1689[Abstract/Free Full Text]
  15. Haase J, Escaned J, van Swijndregt EM. Experimental validation of geometric and densitometric coronary measurements on the new generation Cardiovascular Angiography Analysis System (CAAS II). Cathet Cardiovasc Diagn. 1993;30:104–114[ISI][Medline]
  16. Di Mario C, Hermans WR, Rensing BJ, Serruys PW. Calibration using angiographic catheters as scaling devices— importance of filming the catheters not filled with contrast medium. Am J Cardiol. 1992;69:1377–1378[CrossRef][ISI][Medline]
  17. Serruys PW, Foley DP, de Feyter PJ. Quantitative coronary angiography in clinical practice. Dordrecht, Boston, London: Kluwer Academic Publishers; 1994.
  18. Kuntz RE, Gibson CM, Nobuyoshi M, Baim DS. Generalized model of restenosis after conventional balloon angioplasty, stenting and directional atherectomy. J Am Coll Cardiol. 1993;21:15–25[Abstract]
  19. Blackburn H, Keys A, Simonson E, Rautaharju P, Punsar S. The electrocardiogram in population studies: a classification system. Circulation. 1960;21:1160–1175[Abstract/Free Full Text]
  20. Ellis, SG, Topol, EJ, Intracoronary stents: will they fulfill their promise as an adjunct to angioplasty?, J Am Coll Cardiol, 1989, 14, 264, J Am Coll Cardiol, 1989, 13, 1425, 30
  21. Costa MA, Sabate M, van der Giessen WJ. Late coronary occlusion after intracoronary brachytherapy. Circulation. 1999;100:789–792[Abstract/Free Full Text]
  22. Serruys PW, Kay IP. I Like the Candy, I Hate the Wrapper. The 32P Radioactive stent. Circulation. 2000;101:3–7[Free Full Text]
  23. Wentzel JJ, Whelan DM, van der Giessen WJ. Coronary stent implantation changes 3-D vessel geometry and 3-D shear stress distribution. J Biomech. 2000;33:1287–1295[CrossRef][ISI][Medline]
  24. Sabate M, Kay IP, Gijzel AL. Compassionate use of intracoronary beta-irradiation for treatment of recurrent in-stent restenosis. J Invasive Cardiol. 1999;11:582–588[ISI][Medline]

Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
CirculationHome page
A. V. Finn, F. D. Kolodgie, J. Harnek, L.J. Guerrero, E. Acampado, K. Tefera, K. Skorija, D. K. Weber, H. K. Gold, and R. Virmani
Differential Response of Delayed Healing and Persistent Inflammation at Sites of Overlapping Sirolimus- or Paclitaxel-Eluting Stents
Circulation, July 12, 2005; 112(2): 270 - 278.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
K. Tanabe, P. W. Serruys, E. Grube, P. C. Smits, G. Selbach, W. J. van der Giessen, M. Staberock, P. de Feyter, R. Muller, E. Regar, et al.
TAXUS III Trial: In-Stent Restenosis Treated With Stent-Based Delivery of Paclitaxel Incorporated in a Slow-Release Polymer Formulation
Circulation, February 4, 2003; 107(4): 559 - 564.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
P. W. Serruys, M. Degertekin, K. Tanabe, A. Abizaid, J. E. Sousa, A. Colombo, G. Guagliumi, W. Wijns, W. K. Lindeboom, J. Ligthart, et al.
Intravascular Ultrasound Findings in the Multicenter, Randomized, Double-Blind RAVEL (RAndomized study with the sirolimus-eluting VElocity balloon-expandable stent in the treatment of patients with de novo native coronary artery Lesions) Trial
Circulation, August 13, 2002; 106(7): 798 - 803.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
A.J. Wardeh, R. Albiero, I.P. Kay, A.H.M. Knook, W. Wijns, K. Kozuma, T. Nishida, V. Ferrero, P.C. Levendag, W.J. van der Giessen, et al.
Angiographical Follow-Up After Radioactive "Cold Ends" Stent Implantation: A Multicenter Trial
Circulation, February 5, 2002; 105(5): 550 - 553.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
W. J. van der Giessen, E. Regar, M. S. Harteveld, V. L.M.A. Coen, R. Bhagwandien, A. Au, P. C. Levendag, J. Ligthart, P. W. Serruys, A. den Boer, et al.
"Edge Effect" of 32P Radioactive Stents Is Caused by the Combination of Chronic Stent Injury and Radioactive Dose Falloff
Circulation, October 30, 2001; 104(18): 2236 - 2241.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
R. Seabra-Gomes
Radioactive stents to reduce restenosis: time for an epitaph?
Eur. Heart J., April 2, 2001; 22(8): 621 - 623.
[PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (15)
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Wardeh, A.J
Right arrow Articles by Serruys, P.W
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wardeh, A.J
Right arrow Articles by Serruys, P.W
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?