Skip Navigation

European Heart Journal 2002 23(9):734-741; doi:10.1053/euhj.2001.2894
Copyright © 2002 by the European Society of Cardiology.
This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (6)
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Kochiadakis, G.E.
Right arrow Articles by Vardas, P.E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kochiadakis, G.E.
Right arrow Articles by Vardas, P.E.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Effect of acute atrial fibrillation on phasic coronary blood flow pattern and flow reserve in humans

G.E. Kochiadakis, E.I. Skalidis, M.D. Kalebubas, N.E. Igoumenidis, S.I. Chrysostomakis, E.M. Kanoupakis, E.N. Simantirakis and P.E. Vardasf1

Cardiology Department, University Hospital of Heraklion, Crete, Greece

revised July 11, 2001; accepted July 18, 2001

Abstract

Aims To assess the effect of experimentally induced atrial fibrillation on coronary flow in humans.

Methods and Results In 16 patients (10 men, mean age 43±13 years) with normal coronary vessels, baseline and hyperaemic blood pressure and Doppler phasic coronary flow velocity were measured, using a 0·014inch intracoronary Doppler flow wire, during sinus rhythm, experimentally induced atrial fibrillation, and right atrial pacing at a similar heart rate to that during atrial fibrillation. Coronary flow velocity integral per minute increased significantly during both right atrial pacing and atrial fibrillation compared to sinus rhythm, but during right atrial pacing the increase was greater (85±43% vs 52±25%, P<0·001). This difference persisted even after correction for the product of heart rate and blood pressure (1·15±0·51 vs 0·97±0·46, respectively, P<0·02). In a further 12 paced patients (seven men, mean age 54±10 years) with complete atrioventricular block the induction of atrial fibrillation (atrial fibrillation with regular RR interval) caused no significant changes in coronary flow velocity variables.

Conclusions Acute atrial fibrillation in humans causes an increase in coronary flow that is, however, insufficient to compensate for the augmented myocardial oxygen demand, mainly because of the irregularity in the ventricular rhythm that exists during atrial fibrillation.

Key Words: Atrial fibrillation, coronary flow, vasoconstriction

f1 Correspondence: Prof. P. E. Vardas, MD, PhD (London), FESC, FACC, Cardiology Department, Heraklion University Hospital, P.O. Box 1352, Stavrakia, Heraklion, Crete, Greece.

References

  1. Friedman HS, O'Connor J, Kottmeier S, Shaughnessy E, McGuinn R. The effects of atrial fibrillation on regional blood flow in the awake dog. Can J Cardiol. 1987;3:240–245[Medline]
  2. White CW, Holida MD, Marcus ML. Effects of acute atrial fibrillation on the vasodilator reserve of the canine atrium. Cardiovasc Res. 1986;20:683–689[ISI][Medline]
  3. Ertl G, Wichmann J, Kaufmann M, Kochsiek K. Alpha-receptor constriction induced by atrial fibrillation during maximal coronary dilatation. Basic Res Cardiol. 1986;81:29–39[CrossRef][ISI][Medline]
  4. Friedman HS, Scorza J, McGuinn R, Shaughnessy E. The effects of atrial fibrillation on myocardial blood flow and energetics. Proc Soc Exp Biol Med. 1985;180:1–8[Abstract]
  5. Wichmann J, Ertl G, Rudolph G, Kochsiek K. Effect of experimentally induced atrial fibrillation on coronary circulation in dogs. Basic Res Cardiol. 1983;78:473–491[CrossRef][ISI][Medline]
  6. Wichmann J, Ertl G, Hohne W, Schweisfurth H, Wernze H, Kochsiek K. Alpha-receptor restriction of coronary blood flow during atrial fibrillation. Am J Cardiol. 1983;52:887–892[CrossRef][ISI][Medline]
  7. Doucette JW, Corl PD, Payne HM. Validation of a Doppler guide wire for intravascular measurement of coronary artery flow velocity. Circulation. 1992;85:1899–1911[Abstract/Free Full Text]
  8. Ofili EO, Labovitz AJ, Kern MJ. Coronary flow velocity dynamics in normal and diseased arteries. Am J Cardiol. 1993;71:3D–9D[CrossRef][Medline]
  9. Nahser PJ, Brown RE, Oskarsson H, Winniford MD, Rossen JD. Maximal coronary flow reserve and metabolic coronary vasodilation in patients with diabetes mellitus. Circulation. 1995;91:635–640[Abstract/Free Full Text]
  10. Daoud EG, Weiss R, Bahu M. Effect of an irregular ventricular rhythm on cardiac output. Am J Cardiol. 1996;78:1433–1436[CrossRef][ISI][Medline]
  11. Clark DM, Plumb VJ, Epstein AE, Kay GN. Hemodynamic effects of an irregular sequence of ventricular cycle lengths during atrial fibrillation. J Am Coll Cardiol. 1997;30:1039–1045[Abstract]
  12. Wilson RF, Wyche K, Christensen BV, Zimmer S, Laxson DD. Effects of adenosine on human coronary arterial circulation. Circulation. 1990;82:1595–1606[Abstract/Free Full Text]
  13. Goto M, Flynn AE, Doucette JW. Effect of intracoronary nitroglycerin administration on phasic pattern and transmural distribution of flow during coronary artery stenosis. Circulation. 1992;85:2296–2304[Abstract/Free Full Text]
  14. Kay GN, Bubien RS, Epstein AE, Plumb VJ. Effect of catheter ablation of the atrioventricular junction on quality of life and exercise tolerance in paroxysmal atrial fibrillation. Am J Cardiol. 1988;62:741–744[CrossRef][ISI][Medline]
  15. Heinz G, Siostrzonek P, Kreiner G, Gossinger H. Improvement in left ventricular systolic function after successful radiofrequency His bundle ablation for drug refractory, chronic atrial fibrillation and recurrent atrial flutter. Am J Cardiol. 1992;69:489–492[CrossRef][ISI][Medline]
  16. Rodriguez LM, Smeets JL, Xie B. Improvement in left ventricular function by ablation of atrioventricular nodal conduction in selected patients with lone atrial fibrillation. Am J Cardiol. 1993;72:1137–1141[CrossRef][ISI][Medline]
  17. Natale A, Zimerman L, Tomassoni G. Impact on ventricular function and quality of life of transcatheter ablation of the atrioventricular junction in chronic atrial fibrillation with a normal ventricular response. Am J Cardiol. 1996;78:1431–1433[CrossRef][ISI][Medline]

Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
EuropaceHome page
A. Bukowska, U. Lendeckel, A. Krohn, G. Keilhoff, S. ten Have, K. H. Neumann, and A. Goette
Atrial fibrillation down-regulates renal neutral endopeptidase expression and induces profibrotic pathways in the kidney
Europace, August 8, 2008; (2008) eun206v1.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
F. T. Range, M. Schafers, T. Acil, K. P. Schafers, P. Kies, M. Paul, S. Hermann, B. Brisse, G. Breithardt, O. Schober, et al.
Impaired myocardial perfusion and perfusion reserve associated with increased coronary resistance in persistent idiopathic atrial fibrillation
Eur. Heart J., September 2, 2007; 28(18): 2223 - 2230.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
Writing Committee Members, V. Fuster, L. E. Ryden, D. S. Cannom, H. J. Crijns, A. B. Curtis, K. A. Ellenbogen, J. L. Halperin, J.-Y. Le Heuzey, G. N. Kay, et al.
ACC/AHA/ESC 2006 guidelines for the management of patients with atrial fibrillation: full text: A report of the American College of Cardiology/American Heart Association Task Force on practice guidelines and the European Society of Cardiology Committee for Practice Guidelines (Writing Committee to Revise the 2001 Guidelines for the Management of Patients With Atrial Fibrillation) Developed in collaboration with the European Heart Rhythm Association and the Heart Rhythm Society
Europace, September 1, 2006; 8(9): 651 - 745.
[Full Text] [PDF]


Home page
J Am Coll CardiolHome page
V. Fuster, L. E. Ryden, D. S. Cannom, H. J. Crijns, A. B. Curtis, K. A. Ellenbogen, J. L. Halperin, J.-Y. Le Heuzey, G. N. Kay, J. E. Lowe, et al.
ACC/AHA/ESC 2006 Guidelines for the Management of Patients With Atrial Fibrillation: A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines and the European Society of Cardiology Committee for Practice Guidelines (Writing Committee to Revise the 2001 Guidelines for the Management of Patients With Atrial Fibrillation) Developed in Collaboration With the European Heart Rhythm Association and the Heart Rhythm Society
J. Am. Coll. Cardiol., August 15, 2006; 48(4): e149 - e246.
[Full Text] [PDF]


Home page
CirculationHome page
V. Fuster, L. E. Ryden, D. S. Cannom, H. J. Crijns, A. B. Curtis, K. A. Ellenbogen, J. L. Halperin, J.-Y. Le Heuzey, G. N. Kay, J. E. Lowe, et al.
ACC/AHA/ESC 2006 Guidelines for the Management of Patients With Atrial Fibrillation: A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines and the European Society of Cardiology Committee for Practice Guidelines (Writing Committee to Revise the 2001 Guidelines for the Management of Patients With Atrial Fibrillation): Developed in Collaboration With the European Heart Rhythm Association and the Heart Rhythm Society
Circulation, August 15, 2006; 114(7): e257 - e354.
[Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
H. Wieneke, C. von Birgelen, M. Haude, H. Eggebrecht, S. Mohlenkamp, A. Schmermund, D. Bose, C. Altmann, T. Bartel, and R. Erbel
Determinants of coronary blood flow in humans: quantification by intracoronary Doppler and ultrasound
J Appl Physiol, March 1, 2005; 98(3): 1076 - 1082.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
A. Abidov, R. Hachamovitch, A. Rozanski, S. W. Hayes, M. M. Santos, M. G. Sciammarella, I. Cohen, J. Gerlach, J. D. Friedman, G. Germano, et al.
Prognostic implications of atrial fibrillation in patients undergoing myocardial perfusion single-photon emission computed tomography
J. Am. Coll. Cardiol., September 1, 2004; 44(5): 1062 - 1070.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
G. Mazzocca, T. Giovannini, F. Frascarelli, A. Fabiani, A. Burali, G. Giappichini, G. Bidi, D. Bernaḅ, E. Manfredini, and G. Corbucci
Heart rate regularisation in patients with permanent atrial fibrillation implanted with a VVI(R) pacemaker
Europace, January 1, 2004; 6(3): 236 - 242.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (6)
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Kochiadakis, G.E.
Right arrow Articles by Vardas, P.E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kochiadakis, G.E.
Right arrow Articles by Vardas, P.E.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?