Skip Navigation

European Heart Journal 2001 22(16):1485-1495; doi:10.1053/euhj.2001.2604
Copyright © 2001 by the European Society of Cardiology.
This Article
Right arrow FREE Full Text (PDF) Freely available
Right arrow References
Right arrow E-letters: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (24)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Kamp, O
Right arrow Articles by Visser, C.A
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kamp, O
Right arrow Articles by Visser, C.A
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Serial evaluation of perfusion defects in patients with a first acute myocardial infarction referred for primary PTCA using intravenous myocardial contrast echocardiography

O Kampa,f1, W Lepperb, J.-L Vanoverscheldec, B.C Aeschbacherd, D Rovaie, P Assayagf, P Vocig, Y Klosterh, A Distanteg and C.A Vissera

a University Hospital Vrije Universiteit, Amsterdam, The Netherlands
b Medical Clinic I, Aachen, Germany
c Université Catholique de Louvain, Brussels, Belgium
d Heart Center, Bern, Switzerland
e Institute of Clinical Physiology, Pisa, Italy
f Hôpital Bichat, Paris, France
g Core Laboratory (CLIP), Pisa, Italy
h Nycomed Imaging, Oslo, Norway

revised November 13, 2000; accepted January 17, 2001

Abstract

Aims To investigate whether myocardial contrast echocardiography using Sonazoid®could be used for the serial evaluation of the presence and extent of myocardial perfusion defects in patients with a first acute myocardial infarction treated with primary PTCA, and specifically, (1) to evaluate safety and efficacy of myocardial contrast echocardiography to detect TIMI flow grade 0–2, (2) to evaluate the success of reperfusion and (3) to predict left ventricular recovery after 4 weeks follow-up.

Methods and Results Fifty-nine patients underwent serial myocardial contrast echocardiography, immediately before primary PTCA (MCE1), 1h (MCE2) and 12–24h after PTCA (MCE3). A perfusion defect was observed in 21 of 24 patients (88%) with anterior acute myocardial infarction. All but one had TIMI flow grade 0–2 prior to PTCA. Nine of 31 patients (29%) with inferior acute myocardial infarction showed a perfusion defect and all had TIMI flow grade 0–2 prior to PTCA. Restoration of TIMI flow grade 3 was achieved in 73% of the patients by primary PTCA. A reduction in size of the initial perfusion defect of at least one segment (16 segment model) or no defect vs persistent defect in patients with anterior acute myocardial infarction was associated with improved global left ventricular function at 4 weeks; mean global wall motion score index 1·29±0·21 vs 1·66±0·31 (P=0·009). Multiple regression analysis in patients with an anterior acute myocardial infarction revealed that the extent of the perfusion defect at MCE3 was a significant (P=0·0005) independent predictor for left ventricular recovery at 4 weeks follow-up. The only other independent predictor was TIMI flow grade 3 post PTCA (P=0·007).

Conclusion Intravenous myocardial contrast echocardiography immediately prior to primary PTCA seems safe and is capable of detecting the presence of a perfusion defect and its subsequent dynamic changes, particularly in patients with a first anterior acute myocardial infarction. A significant reduction in size of the initial perfusion defect using serial myocardial contrast echocardiography predicts functional recovery after 4 weeks and these findings underscore the potential diagnostic value of intravenous myocardial contrast echocardiography.

Key Words: Myocardial infarction, contrast media, echocardiography, microcirculation, myocardial viability

f1 Correspondence: Otto Kamp, Md, Ph.D, University Hospital Vrije Universiteit, Department of Cardiology, P.O. Box 7057, 1007 MB Amsterdam, The Netherlands.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Cardiovasc ResHome page
S. T. Laing and D. D. McPherson
Cardiovascular therapeutic uses of targeted ultrasound contrast agents
Cardiovasc Res, September 1, 2009; 83(4): 626 - 635.
[Abstract] [Full Text] [PDF]


Home page
SEMIN CARDIOTHORAC VASC ANESTHHome page
C. Marcucci, R. Lauer, and A. Mahajan
New Echocardiographic Techniques for Evaluating Left Ventricular Myocardial Function
Seminars in Cardiothoracic and Vascular Anesthesia, December 1, 2008; 12(4): 228 - 247.
[Abstract] [PDF]


Home page
Eur Heart JHome page
H. A.J. Struijker-Boudier, A. E. Rosei, P. Bruneval, P. G. Camici, F. Christ, D. Henrion, B. I. Levy, A. Pries, and J.-L. Vanoverschelde
Evaluation of the microcirculation in hypertension and cardiovascular disease
Eur. Heart J., December 1, 2007; 28(23): 2834 - 2840.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
K. M. Marques, P. Knaapen, R. Boellaard, N. Westerhof, A. A. Lammertsma, C. A. Visser, and F. C. Visser
Hyperaemic microvascular resistance is not increased in viable myocardium after chronic myocardial infarction
Eur. Heart J., October 1, 2007; 28(19): 2320 - 2325.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
P. A. Dijkmans, R. Senior, H. Becher, T. R. Porter, K. Wei, C. A. Visser, and O. Kamp
Myocardial Contrast Echocardiography Evolving as a Clinically Feasible Technique for Accurate, Rapid, and Safe Assessment of Myocardial Perfusion: The Evidence So Far
J. Am. Coll. Cardiol., December 5, 2006; 48(11): 2168 - 2177.
[Abstract] [Full Text] [PDF]


Home page
Eur J EchocardiogrHome page
E. Toledo, L. D. Jacobs, J. A. Lodato, J. M. DeCara, P. Coon, V. Mor-Avi, and R. M. Lang
Quantitative diagnosis of stress-induced myocardial ischemia using analysis of contrast echocardiographic parametric perfusion images
Eur J Echocardiogr, June 1, 2006; 7(3): 217 - 225.
[Abstract] [Full Text] [PDF]


Home page
Eur J EchocardiogrHome page
P.A. Dijkmans, C.A. Visser, and O. Kamp
Adverse reactions to ultrasound contrast agents: Is the risk worth the benefit?
Eur J Echocardiogr, October 1, 2005; 6(5): 363 - 366.
[Abstract] [Full Text] [PDF]


Home page
Eur J EchocardiogrHome page
R Winter and R Willenheimer
The incremental value of myocardial contrast echocardiography (MCE) as a bedside decision-making tool in the coronary care unit
Eur J Echocardiogr, March 1, 2004; 5(2): 149 - 155.
[Full Text] [PDF]


Home page
Eur J EchocardiogrHome page
G. T. Sieswerda, L. J Klein, O. Kamp, E. A Aiazian, W. Lepper, F. C Visser, P. Hanrath, and C. A Visser
Quantitative evaluation of myocardial perfusion in patients with revascularized myocardial infarction: comparison between intravenous myocardial contrast echocardiography and 99mTc-sestamibi single photon emission computed tomography
Eur J Echocardiogr, January 1, 2004; 5(1): 41 - 50.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
E. Balcells, E. R. Powers, W. Lepper, T. Belcik, K. Wei, M. Ragosta, H. Samady, and J. R. Lindner
Detection of myocardial viability by contrast echocardiography in acute infarction predicts recovery of resting function and contractile reserve
J. Am. Coll. Cardiol., March 5, 2003; 41(5): 827 - 833.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
K Greaves, S R Dixon, M Fejka, W W O'Neill, S R Redwood, M S Marber, and R Senior
Myocardial contrast echocardiography is superior to other known modalities for assessing myocardial reperfusion after acute myocardial infarction
Heart, February 1, 2003; 89(2): 139 - 144.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.