Skip Navigation

European Heart Journal 2001 22(7):580-586; doi:10.1053/euhj.2000.2261
Copyright © 2001 by the European Society of Cardiology.
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (2)
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Costa, M.A
Right arrow Articles by Sluiter, W
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Costa, M.A
Right arrow Articles by Sluiter, W
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Indirect evidence for a role of a subpopulation of activated neutrophils in the remodelling process after percutaneous coronary intervention

M.A Costaa,f1, L.E.A de Witb,f1, V de Valkc, P Serranoa, A.J Wardeha, P.W Serruysa,f2 and W Sluiterb

a Thoraxcenter, Dijkzigt University Hospital, Rotterdam, The Netherlands
b Department of Biochemistry, Cardiovascular Research Institute, Erasmus University, Rotterdam, The Netherlands
c Cardialysis BV, Rotterdam, The Netherlands

revised April 25, 2000; accepted April 26, 2000

Abstract

Aim Leukocytes have been implicated in restenosis following percutaneous transluminal coronary angioplasty. We investigated the link between the activated status of circulating neutrophils and restenosis after angioplasty.

Methods and Results The population of 108 patients with single, de novo lesions located in native coronary arteries were treated with elective balloon angioplasty (n=44) or stenting (n=64). Pre-, post-procedure and 6-month follow-up, angiograms were analysed by an independent core laboratory. Blood samples were collected immediately before treatment and the antigen CD66, which is specifically expressed by activated neutrophils, was measured. Overall, the average expression of CD66 was 6·4±3·6 of mean fluorescence intensity. In the stepwise linear regression model, which included biological, clinical and angiographic variables, absolute gain showed a direct association (P<0·001) with relative late loss (relative late loss=absolute late loss÷pre-procedure reference diameter), whereas CD66 expression was inversely associated with relative late loss (P=0·004). CD66 expression also showed an inverse association with relative late loss in the balloon angioplasty treated patients (P=0·002, ß=–0·49). In the stent subgroup, only reference vessel diameter and acute gain were independent predictors of relative late loss.

Conclusion Our results confirm the beneficial role of activated neutrophils pre-procedure in the restenotic process after balloon angioplasty. The lack of a relationship between CD66 expression by neutrophils and relative late loss after stenting suggests that this leukocyte may be involved in the remodelling process.

Key Words: Balloon angioplasty, stent, restenosis, leukocytes

f1 Equal contribution.

f2 Correspondence: P. W. Serruys MD, PhD, FACC, FESC Prof. of Interventional Cardiology, Erasmus University, Head of Interventional Dept., Heartcenter Rotterdam, Thoraxcenter, Bd. 418, University Hospital Dijkzigt, Dr. Molewaterplein 40,3015 GD Rotterdam, The Netherlands.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
CirculationHome page
M. A. Costa and D. I. Simon
Molecular Basis of Restenosis and Drug-Eluting Stents
Circulation, May 3, 2005; 111(17): 2257 - 2273.
[Full Text] [PDF]



Disclaimer:
Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.