Continous haemodynamic monitoring during withdrawal of diuretics in patients with congestive heart failure
a Department of Cardiology, Karolinska Hospital, Stockholm, Sweden
b Department of Clinical Physiology, Karolinska Hospital, Stockholm, Sweden
revised March 14, 2001; accepted March 21, 2001
Abstract
Aims Right heart pressure parameters can be recorded continuously with the help of an implanted haemodynamic monitor. The aim of this study was to investigate the usefulness of the device in adjusting diuretic medication in patients with chronic congestive heart failure, and to evaluate the response of right ventricular pressure to increased volume load induced by diuretic withdrawal.
Methods and Results Four patients with stable congestive heart failure were implanted with an implantable haemodynamic monitor. Furosemide, the only diuretic used, was reduced by 50% the first week, withdrawn completely for the second week and then reinstituted in the initial dose. Right ventricular systolic and diastolic pressure, pulse pressure, dP/dt, estimated diastolic pulmonary artery pressure and heart rate were sampled continuously. Patients were evaluated by body weight, NYHA class, serum creatinine, serum brain natriuretic peptide, the 6min walk test, quality of life and echocardiography on days 0, 7, 14 and 21. We observed significant changes in right ventricular pressure parameters in parallel with clinical signs and symptoms of worsening heart failure, such as increased body weight, a shorter walking distance and impaired quality of life. Moreover elevated levels of brain natriuretic peptide and lower creatinine levels were observed.
Conclusion Haemodynamic changes due to increased volume load can be detected with an implantable haemodynamic monitor. Such data provide useful information for tailoring an optimal diuretic dose in patients with congestive heart failure.
Key Words: Haemodynamic monitoring, ambulatory, congestive heart failure, therapy, loop diuretics
f1 Correspondence: Frieder Braunschweig MD, Department of Cardiology, Karolinska Hospital, S-17176 Stockholm, Sweden.
![]()
CiteULike
Connotea
Del.icio.us What's this?
This article has been cited by other articles:
![]() |
F. Braunschweig, C. Linde, P. B. Adamson, A. Magalski, E. Erdmann, B. Kjellstrom, and T. Bennett Continuous central haemodynamic measurements during the six-minute walk test and daily life in patients with chronic heart failure Eur J Heart Fail, June 1, 2009; 11(6): 594 - 601. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. R. Zile, T. D. Bennett, M. St. John Sutton, Y. K. Cho, P. B. Adamson, M. F. Aaron, J. M. Aranda Jr, W. T. Abraham, F. W. Smart, L. W. Stevenson, et al. Transition From Chronic Compensated to Acute Decompensated Heart Failure: Pathophysiological Insights Obtained From Continuous Monitoring of Intracardiac Pressures Circulation, September 30, 2008; 118(14): 1433 - 1441. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. C. Bourge, W. T. Abraham, P. B. Adamson, M. F. Aaron, J. M. Aranda Jr, A. Magalski, M. R. Zile, A. L. Smith, F. W. Smart, M. A. O'Shaughnessy, et al. Randomized controlled trial of an implantable continuous hemodynamic monitor in patients with advanced heart failure: the COMPASS-HF study. J. Am. Coll. Cardiol., March 18, 2008; 51(11): 1073 - 1079. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. Braunschweig, B. Kjellstrom, M. Soderhall, N. Clyne, and C. Linde Dynamic changes in right ventricular pressures during haemodialysis recorded with an implantable haemodynamic monitor Nephrol. Dial. Transplant., January 1, 2006; 21(1): 176 - 183. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. M. Wadas The Implantable Hemodynamic Monitoring System Crit. Care Nurse, October 1, 2005; 25(5): 14 - 26. [Full Text] [PDF] |
||||
![]() |
S. Capomolla, M. Ceresa, G. Pinna, R. Maestri, M. T. La Rovere, O. Febo, A. Rossi, V. Paganini, A. Caporotondi, G. Guazzotti, et al. Echo-Doppler and clinical evaluations to define hemodynamic profile in patients with chronic heart failure: accuracy and influence on therapeutic management Eur J Heart Fail, June 1, 2005; 7(4): 624 - 630. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Gupta and L. Neyses Diuretic usage in heart failure: a continuing conundrum in 2005 Eur. Heart J., April 1, 2005; 26(7): 644 - 649. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Metra, S. Nodari, and L. Dei Cas Current guidelines in the pharmacological management of chronic heart failure Journal of Renin-Angiotensin-Aldosterone System, March 1, 2004; 5(1_suppl): S11 - S16. [Abstract] [PDF] |
||||
![]() |
F. M. Fruhwald, B. Kjellstrom, W. Perthold, N. Watzinger, R. Maier, P. A. Grandjean, and W. Klein Continuous Hemodynamic Monitoring in Pulmonary Hypertensive Patients Treated With Inhaled Iloprost Chest, July 1, 2003; 124(1): 351 - 359. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. B. Adamson, A. Magalski, F. Braunschweig, M. Bohm, D. Reynolds, D. Steinhaus, A. Luby, C. Linde, L. Ryden, B. Cremers, et al. Ongoing right ventricular hemodynamics in heart failure: clinical value of measurements derived from an implantable monitoring system J. Am. Coll. Cardiol., February 19, 2003; 41(4): 565 - 571. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. Erdmann The value of diuretics in chronic heart failure demonstrated by an implanted haemodynamic monitor Eur. Heart J., January 1, 2002; 23(1): 7 - 9. [Full Text] [PDF] |
||||