Skip Navigation

European Heart Journal 2002 23(1):59-69; doi:10.1053/euhj.2001.2690
Copyright © 2002 by the European Society of Cardiology.
This Article
Right arrow FREE Full Text (PDF) Freely available
Right arrow References
Right arrow E-letters: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (34)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Braunschweig, F.
Right arrow Articles by Rydén, L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Braunschweig, F.
Right arrow Articles by Rydén, L.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Continous haemodynamic monitoring during withdrawal of diuretics in patients with congestive heart failure

F. Braunschweiga,f1, C. Lindea, M.J. Erikssonb, C. Hofman-Banga and L. Rydéna

a Department of Cardiology, Karolinska Hospital, Stockholm, Sweden
b Department of Clinical Physiology, Karolinska Hospital, Stockholm, Sweden

revised March 14, 2001; accepted March 21, 2001

Abstract

Aims Right heart pressure parameters can be recorded continuously with the help of an implanted haemodynamic monitor. The aim of this study was to investigate the usefulness of the device in adjusting diuretic medication in patients with chronic congestive heart failure, and to evaluate the response of right ventricular pressure to increased volume load induced by diuretic withdrawal.

Methods and Results Four patients with stable congestive heart failure were implanted with an implantable haemodynamic monitor. Furosemide, the only diuretic used, was reduced by 50% the first week, withdrawn completely for the second week and then reinstituted in the initial dose. Right ventricular systolic and diastolic pressure, pulse pressure, dP/dt, estimated diastolic pulmonary artery pressure and heart rate were sampled continuously. Patients were evaluated by body weight, NYHA class, serum creatinine, serum brain natriuretic peptide, the 6min walk test, quality of life and echocardiography on days 0, 7, 14 and 21. We observed significant changes in right ventricular pressure parameters in parallel with clinical signs and symptoms of worsening heart failure, such as increased body weight, a shorter walking distance and impaired quality of life. Moreover elevated levels of brain natriuretic peptide and lower creatinine levels were observed.

Conclusion Haemodynamic changes due to increased volume load can be detected with an implantable haemodynamic monitor. Such data provide useful information for tailoring an optimal diuretic dose in patients with congestive heart failure.

Key Words: Haemodynamic monitoring, ambulatory, congestive heart failure, therapy, loop diuretics

f1 Correspondence: Frieder Braunschweig MD, Department of Cardiology, Karolinska Hospital, S-17176 Stockholm, Sweden.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Eur J Heart FailHome page
F. Braunschweig, C. Linde, P. B. Adamson, A. Magalski, E. Erdmann, B. Kjellstrom, and T. Bennett
Continuous central haemodynamic measurements during the six-minute walk test and daily life in patients with chronic heart failure
Eur J Heart Fail, June 1, 2009; 11(6): 594 - 601.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
M. R. Zile, T. D. Bennett, M. St. John Sutton, Y. K. Cho, P. B. Adamson, M. F. Aaron, J. M. Aranda Jr, W. T. Abraham, F. W. Smart, L. W. Stevenson, et al.
Transition From Chronic Compensated to Acute Decompensated Heart Failure: Pathophysiological Insights Obtained From Continuous Monitoring of Intracardiac Pressures
Circulation, September 30, 2008; 118(14): 1433 - 1441.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
R. C. Bourge, W. T. Abraham, P. B. Adamson, M. F. Aaron, J. M. Aranda Jr, A. Magalski, M. R. Zile, A. L. Smith, F. W. Smart, M. A. O'Shaughnessy, et al.
Randomized controlled trial of an implantable continuous hemodynamic monitor in patients with advanced heart failure: the COMPASS-HF study.
J. Am. Coll. Cardiol., March 18, 2008; 51(11): 1073 - 1079.
[Abstract] [Full Text] [PDF]


Home page
Nephrol Dial TransplantHome page
F. Braunschweig, B. Kjellstrom, M. Soderhall, N. Clyne, and C. Linde
Dynamic changes in right ventricular pressures during haemodialysis recorded with an implantable haemodynamic monitor
Nephrol. Dial. Transplant., January 1, 2006; 21(1): 176 - 183.
[Abstract] [Full Text] [PDF]


Home page
Crit Care NurseHome page
T. M. Wadas
The Implantable Hemodynamic Monitoring System
Crit. Care Nurse, October 1, 2005; 25(5): 14 - 26.
[Full Text] [PDF]


Home page
Eur J Heart FailHome page
S. Capomolla, M. Ceresa, G. Pinna, R. Maestri, M. T. La Rovere, O. Febo, A. Rossi, V. Paganini, A. Caporotondi, G. Guazzotti, et al.
Echo-Doppler and clinical evaluations to define hemodynamic profile in patients with chronic heart failure: accuracy and influence on therapeutic management
Eur J Heart Fail, June 1, 2005; 7(4): 624 - 630.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
S. Gupta and L. Neyses
Diuretic usage in heart failure: a continuing conundrum in 2005
Eur. Heart J., April 1, 2005; 26(7): 644 - 649.
[Abstract] [Full Text] [PDF]


Home page
Journal of Renin-Angiotensin-Aldosterone SystemHome page
M. Metra, S. Nodari, and L. Dei Cas
Current guidelines in the pharmacological management of chronic heart failure
Journal of Renin-Angiotensin-Aldosterone System, March 1, 2004; 5(1_suppl): S11 - S16.
[Abstract] [PDF]


Home page
ChestHome page
F. M. Fruhwald, B. Kjellstrom, W. Perthold, N. Watzinger, R. Maier, P. A. Grandjean, and W. Klein
Continuous Hemodynamic Monitoring in Pulmonary Hypertensive Patients Treated With Inhaled Iloprost
Chest, July 1, 2003; 124(1): 351 - 359.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
P. B. Adamson, A. Magalski, F. Braunschweig, M. Bohm, D. Reynolds, D. Steinhaus, A. Luby, C. Linde, L. Ryden, B. Cremers, et al.
Ongoing right ventricular hemodynamics in heart failure: clinical value of measurements derived from an implantable monitoring system
J. Am. Coll. Cardiol., February 19, 2003; 41(4): 565 - 571.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
E. Erdmann
The value of diuretics in chronic heart failure demonstrated by an implanted haemodynamic monitor
Eur. Heart J., January 1, 2002; 23(1): 7 - 9.
[Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.