Skip Navigation

European Heart Journal 2002 23(13):1045-1049; doi:10.1053/euhj.2001.3076
Copyright © 2002 by the European Society of Cardiology.
This Article
Right arrow FREE Full Text (PDF) Freely available
Right arrow References
Right arrow E-letters: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (23)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Boudjemline, Y.
Right arrow Articles by Bonhoeffer, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Boudjemline, Y.
Right arrow Articles by Bonhoeffer, P.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Percutaneous implantation of a valve in the descending aorta in lambs

Y. Boudjemlinea and P. Bonhoefferb,f1

a Service de Cardiologie Pédiatrique, Hôpital Necker Enfants Malades, Paris, France
b Cardiothoracic Unit, Great Ormond Street Hospital, London, U.K.

revised October 22, 2001; accepted November 7, 2001

Abstract

Aims We assessed the feasibility of percutaneous implantation of a valve in the descending aorta and its function in systemic pressures.

Methods and Results A biological valve harvested from a bovine jugular vein was sutured into a stent. After the creation of aortic insufficiency, the valved stent was percutaneously implanted into eight lambs divided into two groups depending on the severity of the insufficiency created. Haemodynamic and angiographic evaluations were carried out. Anatomical evaluation was finally performed. Aortic insufficiency was created: four lambs had mild insufficiency and four massive insufficiency. A valve was successfully implanted in all and were functioning perfectly in the early follow-up. Despite this competence, animals with massive insufficiency died within 24h following implantation. None of the animals with mild insufficiency died. The valve was functioning perfectly in the first 2 months following the implantation, but became incompetent after spontaneous healing of the wound of the aortic valve.

Conclusion Percutaneously implanted valves in the descending aorta of lambs with aortic insufficiency function well in the early follow-up. This technique might become an interesting alternative to the standard approach in patients in whom perioperative risk is high. Copyright 2002 The European Society of Cardiology. Published by Elsevier Science Ltd. All rights reserved.

Key Words: Stents, catheterization, prosthesis, valves, aortic valve disease

f1 Correspondence: Dr Philipp Bonhoeffer, Cardiothoracic Unit, Great Ormond Street Hospital for Children NHS Trust, Great Ormond Street, London WC1N 3JH, U.K.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
J Am Coll Cardiol IntvHome page
P. T.L. Chiam and C. E. Ruiz
Percutaneous Transcatheter Aortic Valve Implantation: Assessing Results, Judging Outcomes, and Planning Trials: The Interventionalist Perspective
J. Am. Coll. Cardiol. Intv., August 1, 2008; 1(4): 341 - 350.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
M. J. Antunes
Off-pump aortic valve replacement with catheter-mounted valved stents.: Is the future already here?
Eur. J. Cardiothorac. Surg., January 1, 2007; 31(1): 1 - 3.
[Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
J. Ye, A. Cheung, S. V. Lichtenstein, S. Pasupati, R. G. Carere, C. R. Thompson, A. Sinhal, and J. G. Webb
Six-month outcome of transapical transcatheter aortic valve implantation in the initial seven patients
Eur. J. Cardiothorac. Surg., January 1, 2007; 31(1): 16 - 21.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
E. Grube, J. C. Laborde, U. Gerckens, T. Felderhoff, B. Sauren, L. Buellesfeld, R. Mueller, M. Menichelli, T. Schmidt, B. Zickmann, et al.
Percutaneous Implantation of the CoreValve Self-Expanding Valve Prosthesis in High-Risk Patients With Aortic Valve Disease: The Siegburg First-in-Man Study
Circulation, October 10, 2006; 114(15): 1616 - 1624.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
S. V. Lichtenstein, A. Cheung, J. Ye, C. R. Thompson, R. G. Carere, S. Pasupati, and J. G. Webb
Transapical Transcatheter Aortic Valve Implantation in Humans: Initial Clinical Experience
Circulation, August 8, 2006; 114(6): 591 - 596.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
J. G. Webb, M. Chandavimol, C. R. Thompson, D. R. Ricci, R. G. Carere, B. I. Munt, C. E. Buller, S. Pasupati, and S. Lichtenstein
Percutaneous Aortic Valve Implantation Retrograde From the Femoral Artery
Circulation, February 14, 2006; 113(6): 842 - 850.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
Y. Boudjemline, E. Pineau, N. Borenstein, L. Behr, and P. Bonhoeffer
New insights in minimally invasive valve replacement: description of a cooperative approach for the off-pump replacement of mitral valves
Eur. Heart J., October 1, 2005; 26(19): 2013 - 2017.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
Y. Boudjemline, G. Agnoletti, D. Bonnet, L. Behr, N. Borenstein, D. Sidi, and P. Bonhoeffer
Steps Toward the Percutaneous Replacement of Atrioventricular Valves: An Experimental Study
J. Am. Coll. Cardiol., July 19, 2005; 46(2): 360 - 365.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
Y. Boudjemline, S. Schievano, C. Bonnet, L. Coats, G. Agnoletti, S. Khambadkone, D. Bonnet, J. Deanfield, D. Sidi, and P. Bonhoeffer
Off-pump replacement of the pulmonary valve in large right ventricular outflow tracts: A hybrid approach
J. Thorac. Cardiovasc. Surg., April 1, 2005; 129(4): 831 - 837.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
C. H. Huber, P. Tozzi, A. F. Corno, B. Marty, P. Ruchat, P. Gersbach, M. Nasratulla, and L. K. von Segesser
Do valved stents compromise coronary flow?
Eur. J. Cardiothorac. Surg., May 1, 2004; 25(5): 754 - 759.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
A. Vahanian and I. F. Palacios
Percutaneous Approaches to Valvular Disease
Circulation, April 6, 2004; 109(13): 1572 - 1579.
[Full Text] [PDF]


Home page
J Am Coll CardiolHome page
Y. Boudjemline, G. Agnoletti, D. Bonnet, D. Sidi, and P. Bonhoeffer
Percutaneous pulmonary valve replacement in a large right ventricular outflow tract: An experimental study
J. Am. Coll. Cardiol., March 17, 2004; 43(6): 1082 - 1087.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
A. Cribier, H. Eltchaninoff, C. Tron, F. Bauer, C. Agatiello, L. Sebagh, A. Bash, D. Nusimovici, P. Y. Litzler, J.-P. Bessou, et al.
Early experience with percutaneous transcatheter implantation of heart valve prosthesis for the treatment of end-stage inoperable patients with calcific aortic stenosis
J. Am. Coll. Cardiol., February 18, 2004; 43(4): 698 - 703.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
L.A. van Herwerden and P.W. Serruys
Percutaneous valve implantation: back to the future?
Eur. Heart J., September 2, 2002; 23(18): 1415 - 1416.
[Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.