Copyright © 2002 by the European Society of Cardiology.
Editorials
Catheter ablation of macroreentrant atrial tachycardia in patients following atriotomy
Cardiac Arrhythmia Research Institute, University of Oklahoma Health Sciences Center, Oklahoma City, Oklahoma, U.S.A.
References
- Flinn CJ, Wolff GS, Dick M. Cardiac rhythm after the Mustard operation for complete transposition of the great arteries. N Engl J Med. 1984;310:16351642[Abstract]
- Van Hare GF, Lesh MD, Stanger P. Radiofrequency catheter ablation of supraventricular tachyarrhythmias in patients with congenital heart disease: results and technical considerations. J Am Coll Cardiol. 1993;22:883890[Abstract]
- Gelatt M, Hamilton RM, McCrindle BW. Risk factors for atrial tachydysrhythmias after Fontan operation. J Am Coll Cardiol. 1994;24:17351741[Abstract]
- Triedman JK, Saul P, Weindling SN, Walsh EP. Radiofrequency ablation of intra-atrial reentrant tachycardia after surgical palliation of congenital heart disease. Circulation. 1995;91:707714
[Abstract/Free Full Text] - Kalman JM, VanHare GF, Olgin JE. Ablation of incisional reentrant atrial tachycardia complication surgery for congenital heart disease. Circulation. 1996;93:502512
[Abstract/Free Full Text] - Baker BM, Lindsay BD, Bromberg B. Catheter ablation of intraatrial reentrant tachycardias resulting from previous atrial surgery: location and transecting the critical isthmus. J Am Coll Cardiol. 1996;28:411417[Abstract]
- Triedman JK, Bergau FD, Saul P, Epstein MR, Walsh EP. Efficacy of radiofrequency ablation for control of intraatrial reentrant tachycardia in patients with congenital heart disease. J Am Coll Cardiol. 1997;30:10321038[Abstract]
- Triedman JK, Jenkins KJ, Colan SD, Saul JP, Walsh EP. Intra-atrial reentrant tachycardia after palliation of congenital heat disease: Characterization of multiple macroreentrant circuit using fluoroscopically based three-dimensional endocardial mapping. J Cardiovasc Electrophysiol. 1997;8:259270[Web of Science][Medline]
- Anne W, Rensburg HV, Adams J. Ablation of postsurgical intraatrial reentrant tachycardia: Predilection target sites and mapping approach. Eur Heart J. 2002;23:16091616
[Abstract/Free Full Text] - Ben-Haim SA, Osadchy D, Schuster I. Nonfluoroscopic, in vivo navigation and mapping technology. Nature Medicine. 1996;2:13931395[CrossRef][Web of Science][Medline]
- Nakagawa H, Jackman WM. Use of a three-dimensional, nonfluoroscopic mapping system for catheter ablation of typical atrial flutter. PACE. 1998;21:12791286
- Nakagawa H, Shah N, Matsudaira K. Chracterization of reentrant circuit in macroreentrant right atrial tachycardia after surgical repair of congenital heart disease: Isolated channel between scars allow focal ablation. Circulation. 2001;103:699709
[Abstract/Free Full Text] - Waldo AL, Plumb VJ, Arciniesgas JG. Transient entrainment and interruption of atrioventricular bypass pathway type of paroxysmal atrial tachycardia: a model for understanding and identifying reentrant arrhythmias. Circulation. 1983;67:7383
[Free Full Text] - Stevenson WG, Khan H, Sager P. Identification of reentry circuit sites during catheter mapping and radiofrequency ablation of ventricular tachycardia late after myocardial infraction. Circulation. 1993;88:16471670
[Abstract/Free Full Text] - Nakagawa H, Beckman K, Spector P. Characterization of the reentrant circuit in macroreentrant left atrial tachycardia (Abstr). Circulation. 2001;104:172181
This article has been cited by other articles:
![]() |
P. Ballo, D. Bernabo, and S. A. Faraguti Heart rate is a predictor of success in the treatment of adults with symptomatic paroxysmal supraventricular tachycardia Eur. Heart J., August 1, 2004; 25(15): 1310 - 1317. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
