Skip Navigation

European Heart Journal 2002 23(9):734-741; doi:10.1053/euhj.2001.2894
Copyright © 2002 by the European Society of Cardiology.
This Article
Right arrow FREE Full Text (PDF) Freely available
Right arrow References
Right arrow E-letters: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (6)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Kochiadakis, G.E.
Right arrow Articles by Vardas, P.E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kochiadakis, G.E.
Right arrow Articles by Vardas, P.E.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Effect of acute atrial fibrillation on phasic coronary blood flow pattern and flow reserve in humans

G.E. Kochiadakis, E.I. Skalidis, M.D. Kalebubas, N.E. Igoumenidis, S.I. Chrysostomakis, E.M. Kanoupakis, E.N. Simantirakis and P.E. Vardasf1

Cardiology Department, University Hospital of Heraklion, Crete, Greece

revised July 11, 2001; accepted July 18, 2001

Abstract

Aims To assess the effect of experimentally induced atrial fibrillation on coronary flow in humans.

Methods and Results In 16 patients (10 men, mean age 43±13 years) with normal coronary vessels, baseline and hyperaemic blood pressure and Doppler phasic coronary flow velocity were measured, using a 0·014inch intracoronary Doppler flow wire, during sinus rhythm, experimentally induced atrial fibrillation, and right atrial pacing at a similar heart rate to that during atrial fibrillation. Coronary flow velocity integral per minute increased significantly during both right atrial pacing and atrial fibrillation compared to sinus rhythm, but during right atrial pacing the increase was greater (85±43% vs 52±25%, P<0·001). This difference persisted even after correction for the product of heart rate and blood pressure (1·15±0·51 vs 0·97±0·46, respectively, P<0·02). In a further 12 paced patients (seven men, mean age 54±10 years) with complete atrioventricular block the induction of atrial fibrillation (atrial fibrillation with regular RR interval) caused no significant changes in coronary flow velocity variables.

Conclusions Acute atrial fibrillation in humans causes an increase in coronary flow that is, however, insufficient to compensate for the augmented myocardial oxygen demand, mainly because of the irregularity in the ventricular rhythm that exists during atrial fibrillation.

Key Words: Atrial fibrillation, coronary flow, vasoconstriction

f1 Correspondence: Prof. P. E. Vardas, MD, PhD (London), FESC, FACC, Cardiology Department, Heraklion University Hospital, P.O. Box 1352, Stavrakia, Heraklion, Crete, Greece.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Eur Heart JHome page
A. Goette, A. Bukowska, D. Dobrev, J. Pfeiffenberger, H. Morawietz, D. Strugala, I. Wiswedel, F.-W. Rohl, C. Wolke, S. Bergmann, et al.
Acute atrial tachyarrhythmia induces angiotensin II type 1 receptor-mediated oxidative stress and microvascular flow abnormalities in the ventricles
Eur. Heart J., June 1, 2009; 30(11): 1411 - 1420.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
F. T. Range, M. Paul, K. P. Schafers, T. Acil, P. Kies, S. Hermann, O. Schober, G. Breithardt, T. Wichter, and M. A. Schafers
Myocardial Perfusion in Nonischemic Dilated Cardiomyopathy With and Without Atrial Fibrillation
J. Nucl. Med., March 1, 2009; 50(3): 390 - 396.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
A. Bukowska, U. Lendeckel, A. Krohn, G. Keilhoff, S. t. Have, K. H. Neumann, and A. Goette
Atrial fibrillation down-regulates renal neutral endopeptidase expression and induces profibrotic pathways in the kidney
Europace, October 1, 2008; 10(10): 1212 - 1217.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
F. T. Range, M. Schafers, T. Acil, K. P. Schafers, P. Kies, M. Paul, S. Hermann, B. Brisse, G. Breithardt, O. Schober, et al.
Impaired myocardial perfusion and perfusion reserve associated with increased coronary resistance in persistent idiopathic atrial fibrillation
Eur. Heart J., September 2, 2007; 28(18): 2223 - 2230.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
Writing Committee Members, V. Fuster, L. E. Ryden, D. S. Cannom, H. J. Crijns, A. B. Curtis, K. A. Ellenbogen, J. L. Halperin, J.-Y. Le Heuzey, G. N. Kay, et al.
ACC/AHA/ESC 2006 guidelines for the management of patients with atrial fibrillation: full text: A report of the American College of Cardiology/American Heart Association Task Force on practice guidelines and the European Society of Cardiology Committee for Practice Guidelines (Writing Committee to Revise the 2001 Guidelines for the Management of Patients With Atrial Fibrillation) Developed in collaboration with the European Heart Rhythm Association and the Heart Rhythm Society
Europace, September 1, 2006; 8(9): 651 - 745.
[Full Text] [PDF]


Home page
J Am Coll CardiolHome page
V. Fuster, L. E. Ryden, D. S. Cannom, H. J. Crijns, A. B. Curtis, K. A. Ellenbogen, J. L. Halperin, J.-Y. Le Heuzey, G. N. Kay, J. E. Lowe, et al.
ACC/AHA/ESC 2006 Guidelines for the Management of Patients With Atrial Fibrillation: A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines and the European Society of Cardiology Committee for Practice Guidelines (Writing Committee to Revise the 2001 Guidelines for the Management of Patients With Atrial Fibrillation) Developed in Collaboration With the European Heart Rhythm Association and the Heart Rhythm Society
J. Am. Coll. Cardiol., August 15, 2006; 48(4): e149 - e246.
[Full Text] [PDF]


Home page
CirculationHome page
V. Fuster, L. E. Ryden, D. S. Cannom, H. J. Crijns, A. B. Curtis, K. A. Ellenbogen, J. L. Halperin, J.-Y. Le Heuzey, G. N. Kay, J. E. Lowe, et al.
ACC/AHA/ESC 2006 Guidelines for the Management of Patients With Atrial Fibrillation: A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines and the European Society of Cardiology Committee for Practice Guidelines (Writing Committee to Revise the 2001 Guidelines for the Management of Patients With Atrial Fibrillation): Developed in Collaboration With the European Heart Rhythm Association and the Heart Rhythm Society
Circulation, August 15, 2006; 114(7): e257 - e354.
[Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
H. Wieneke, C. von Birgelen, M. Haude, H. Eggebrecht, S. Mohlenkamp, A. Schmermund, D. Bose, C. Altmann, T. Bartel, and R. Erbel
Determinants of coronary blood flow in humans: quantification by intracoronary Doppler and ultrasound
J Appl Physiol, March 1, 2005; 98(3): 1076 - 1082.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
A. Abidov, R. Hachamovitch, A. Rozanski, S. W. Hayes, M. M. Santos, M. G. Sciammarella, I. Cohen, J. Gerlach, J. D. Friedman, G. Germano, et al.
Prognostic implications of atrial fibrillation in patients undergoing myocardial perfusion single-photon emission computed tomography
J. Am. Coll. Cardiol., September 1, 2004; 44(5): 1062 - 1070.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
G. Mazzocca, T. Giovannini, F. Frascarelli, A. Fabiani, A. Burali, G. Giappichini, G. Bidi, D. Bernaḅ, E. Manfredini, and G. Corbucci
Heart rate regularisation in patients with permanent atrial fibrillation implanted with a VVI(R) pacemaker
Europace, January 1, 2004; 6(3): 236 - 242.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.