Skip Navigation

European Heart Journal 2004 25(14):1249-1256; doi:10.1016/j.ehj.2004.05.017
Copyright © 2004 by the European Society of Cardiology.
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (2)
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Willems, S.
Right arrow Articles by Meinertz, T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Willems, S.
Right arrow Articles by Meinertz, T.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Clinical research

Sub-threshold stimulation in variants of atrioventricular nodal re-entrant tachycardia: electrophysiological effects and impact for guidance of slow pathway ablation

Stephan Willemsa,*, Thomas Rostocka, Mohammad Shenasab, Christian Weissa, Tim Risiusa, Rodolfo Venturaa, Matthias Hoffmanna and Thomas Meinertza

a Department of Cardiology, University Hospital Eppendorf, Martinistrasse 52, 20246 Hamburg, Germany
b Department of Cardiovascular Services, O`Connor Hospital, San Jose, CA, USA

* Corresponding author. Tel.: +49-40-42803-4120; fax: +49-40-42803-4125
E-mail address: willems{at}uke.uni-hamburg.de

Received 11 February 2004; revised 21 March 2004; accepted 13 May 2004

Abstract

Aim Sub-threshold stimulation (STS) applied during atrioventricular nodal re-entrant tachycardia (AVNRT) of the common (slow–fast) type has been shown to effectively characterise target sites suitable for slow pathway (SP) ablation but has not been investigated in the setting of fast–slow and slow–slow variants.

Methods and results Seventeen consecutive patients (52±16 years, 12 female) with sustained uncommon type AVNRT (fast–slow: , slow–slow: ) were investigated. Mapping of the SP was started postero-septally close to the coronary sinus ostium and continued toward mid-septal sites, if required. Target sites for STS were selected according to established criteria including the recording of the earliest retrograde atrial activation during AVNRT. Long duration (5 s) constant current STS during AVNRT variants was performed in a stepwise manner (max 5 mA) at each site eligible for SP ablation until termination or capture occurred. Radiofrequency current (RFC) was delivered following successful STS termination of tachycardia (65 °C, 60 s) and exclusion of catheter dislodgement. Uncommon AVNRT with a mean cycle length of 405±70 ms was induced without spontaneous termination in all patients. Interruption of AVNRT variants due to selective STS-induced block of the retrograde () or anterograde () SP occurred without capture in 14/17 (82%) patients. This was exclusively observed at sites with successful subsequent RFC application. AVNRT was rendered non-inducible in all patients after a median of 1 (1–11) RFC pulses without complications.

Conclusions Uncommon AVNRT can be interrupted by STS delivered at subsequently successful target sites for SP ablation in most patients (82%). The high positive and negative concordance between the effects of STS and following RFC application indicates that STS-mapping is also useful in the setting of AVNRT variants.

Key Words: Atrioventricular nodal re-entrant tachycardia • Variants of AVNRT • Endocardial mapping • Slow pathway ablation • Sub-threshold stimulation


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer:
Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.