Skip Navigation


European Heart Journal Advance Access originally published online on April 19, 2005
European Heart Journal 2005 26(15):1482-1487; doi:10.1093/eurheartj/ehi261
This Article
Right arrow Full Text Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow All Versions of this Article:
26/15/1482    most recent
ehi261v1
Right arrow E-letters: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Related articles in EHJ
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (408)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Leschka, S.
Right arrow Articles by Wildermuth, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Leschka, S.
Right arrow Articles by Wildermuth, S.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The European Society of Cardiology 2005. All rights reserved. For Permissions, please e-mail: journals.permissions@oupjournals.org

Accuracy of MSCT coronary angiography with 64-slice technology: first experience

Sebastian Leschka1, Hatem Alkadhi1, André Plass2, Lotus Desbiolles1, Jürg Grünenfelder2, Borut Marincek1 and Simon Wildermuth1,*

1Department of Medical Radiology, Institute of Diagnostic Radiology, University Hospital Zurich, Rämistrasse 100, 8091 Zurich, Switzerland
2Clinic for Cardiovascular Surgery, University Hospital Zurich, Switzerland

Received 17 December 2004; revised 7 March 2005; accepted 15 March 2005; online publish-ahead-of-print 19 April 2005.

* Corresponding author. Tel: +41 1 255 3662; fax: +41 1 255 4443. E-mail address: simon.wildermuth{at}usz.ch

See page 1451 for the editorial comment on this article (doi:10.1093/eurheartj/ehi322)

Aims The aim of our study was to investigate the accuracy of 64-slice computed tomography (CT) for assessing haemodynamically significant stenoses of coronary arteries.

Methods and results CT angiography was performed in 67 patients (50 male, 17 female; mean age 60.1±10.5 years) with suspected coronary artery disease and compared with invasive coronary angiography. All vessels ≥1.5 mm were considered for the assessment of significant coronary artery stenosis (diameter reduction >50%). Forty-seven patients were identified as having significant coronary stenoses on invasive angiography with 18% (176/1005) affected segments. None of the coronary segments needed to be excluded from analysis. CT correctly identified all 20 patients having no significant stenosis on invasive angiography. Overall sensitivity for classifying stenoses was 94%, specificity was 97%, positive predictive value was 87%, and negative predictive value was 99%.

Conclusion Sixty-four-slice CT provides a high diagnostic accuracy in assessing coronary artery stenoses.

Key Words: Computed tomography • Conventional coronary angiography • Coronary artery disease


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?

Related articles in EHJ:

Non-invasive computed tomographic coronary angiography: the end of the beginning
Axel Schmermund and Raimund Erbel
EHJ 2005 26: 1451-1453. [Extract] [FREE Full Text]  



This article has been cited by other articles:


Home page
RadiologyHome page
G. Bastarrika, Y. S. Lee, W. Huda, B. Ruzsics, P. Costello, and U. J. Schoepf
CT of Coronary Artery Disease
Radiology, November 1, 2009; 253(2): 317 - 338.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
B A Herzog, C A Wyss, L Husmann, O Gaemperli, I Valenta, V Treyer, U Landmesser, and P A Kaufmann
First head-to-head comparison of effective radiation dose from low-dose 64-slice CT with prospective ECG-triggering versus invasive coronary angiography
Heart, October 15, 2009; 95(20): 1656 - 1661.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
W. Wu, J. Budovec, and W. D. Foley
Prospective and Retrospective ECG Gating for Thoracic CT Angiography: A Comparative Study
Am. J. Roentgenol., October 1, 2009; 193(4): 955 - 963.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. Baumuller, S. Leschka, L. Desbiolles, P. Stolzmann, H. Scheffel, B. Seifert, B. Marincek, and H. Alkadhi
Dual-Source versus 64-Section CT Coronary Angiography at Lower Heart Rates: Comparison of Accuracy and Radiation Dose
Radiology, October 1, 2009; 253(1): 56 - 64.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
J M van Werkhoven, O Gaemperli, J D Schuijf, J W Jukema, L J Kroft, S Leschka, H Alkadhi, I Valenta, G Pundziute, A de Roos, et al.
Multislice computed tomography coronary angiography for risk stratification in patients with an intermediate pretest likelihood
Heart, October 1, 2009; 95(19): 1607 - 1611.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll Cardiol ImgHome page
T. Knickelbine, J. R. Lesser, T. S. Haas, E. R. Brandenburg, B. K. Gleason-Han, B. Flygenring, T. F. Longe, R. S. Schwartz, and B. J. Maron
Identification of Unexpected Nonatherosclerotic Cardiovascular Disease With Coronary CT Angiography
J. Am. Coll. Cardiol. Img., September 1, 2009; 2(9): 1085 - 1092.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
F. Wolf, F. Cademartiri, C. Loewe, A. Stadler, M. Weber, J. Lammer, and G. M. Feuchtner
Evaluation of Coronary Stents With 64-MDCT: In Vitro Comparison of Scanners From Four Vendors
Am. J. Roentgenol., September 1, 2009; 193(3): 787 - 794.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
O. Gaemperli, L. Husmann, T. Schepis, P. Koepfli, I. Valenta, W. Jenni, H. Alkadhi, T. F. Luscher, and P. A. Kaufmann
Coronary CT angiography and myocardial perfusion imaging to detect flow-limiting stenoses: a potential gatekeeper for coronary revascularization?
Eur. Heart J., August 14, 2009; (2009) ehp304v1.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll Cardiol ImgHome page
B. M. Wertman, V. Y. Cheng, S. Kar, H. Gransar, R. A. Berg, H. Naik, R. Makkar, J. D. Friedman, J. N. Schapira, and D. S. Berman
Characterization of Complex Coronary Artery Stenosis Morphology by Coronary Computed Tomographic Angiography
J. Am. Coll. Cardiol. Img., August 1, 2009; 2(8): 950 - 958.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
G. Bastarrika, C. Thilo, G. F. Headden, P. L. Zwerner, P. Costello, and U. J. Schoepf
Cardiac CT in the Assessment of Acute Chest Pain in the Emergency Department
Am. J. Roentgenol., August 1, 2009; 193(2): 397 - 409.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
R. W. Bauer, C. Thilo, S. A. Chiaramida, T. J. Vogl, P. Costello, and U. J. Schoepf
Noncalcified Atherosclerotic Plaque Burden at Coronary CT Angiography: A Better Predictor of Ischemia at Stress Myocardial Perfusion Imaging Than Calcium Score and Stenosis Severity
Am. J. Roentgenol., August 1, 2009; 193(2): 410 - 418.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
L HUSMANN, O GAEMPERLI, I VALENTA, T SCHEPIS, H SCHEFFEL, P STOLZMANN, S LESCHKA, L DESBIOLLES, B MARINCEK, H ALKADHI, et al.
Impact of vessel attenuation on quantitative coronary angiography with 64-slice CT
Br. J. Radiol., August 1, 2009; 82(980): 649 - 653.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
G. Pontone, D. Andreini, A. L. Bartorelli, S. Cortinovis, S. Mushtaq, E. Bertella, A. Annoni, A. Formenti, E. Nobili, D. Trabattoni, et al.
Diagnostic accuracy of coronary computed tomography angiography: a comparison between prospective and retrospective electrocardiogram triggering.
J. Am. Coll. Cardiol., July 21, 2009; 54(4): 346 - 355.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
W. P. Shuman, K. R. Branch, J. M. May, L. M. Mitsumori, J. N. Strote, B. H. Warren, T. J. Dubinsky, D. W. Lockhart, and J. H. Caldwell
Whole-Chest 64-MDCT of Emergency Department Patients with Nonspecific Chest Pain: Radiation Dose and Coronary Artery Image Quality with Prospective ECG Triggering Versus Retrospective ECG Gating
Am. J. Roentgenol., June 1, 2009; 192(6): 1662 - 1667.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
P. T. Johnson, H. K. Pannu, and E. K. Fishman
IV Contrast Infusion for Coronary Artery CT Angiography: Literature Review and Results of a Nationwide Survey
Am. J. Roentgenol., May 1, 2009; 192(5): W214 - W221.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
K. M. Takakuwa, E. J. Halpern, E. L. Gingold, D. C. Levin, and F. S. Shofer
Radiation Dose in a "Triple Rule-Out" Coronary CT Angiography Protocol of Emergency Department Patients Using 64-MDCT: The Impact of ECG-Based Tube Current Modulation on Age, Sex, and Body Mass Index
Am. J. Roentgenol., April 1, 2009; 192(4): 866 - 872.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
H. Scheffel, S. Baumueller, P. Stolzmann, S. Leschka, A. Plass, H. Alkadhi, and T. Schertler
Atrial Myxomas and Thrombi: Comparison of Imaging Features on CT
Am. J. Roentgenol., March 1, 2009; 192(3): 639 - 645.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
W. B. Meijboom, M. F.L. Meijs, J. D. Schuijf, M. J. Cramer, N. R. Mollet, C. A.G. van Mieghem, K. Nieman, J. M. van Werkhoven, G. Pundziute, A. C. Weustink, et al.
Diagnostic accuracy of 64-slice computed tomography coronary angiography: a prospective, multicenter, multivendor study.
J. Am. Coll. Cardiol., December 16, 2008; 52(25): 2135 - 2144.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
B. A. Herzog, L. Husmann, N. Burkhard, O. Gaemperli, I. Valenta, F. Tatsugami, C. A. Wyss, U. Landmesser, and P. A. Kaufmann
Accuracy of low-dose computed tomography coronary angiography using prospective electrocardiogram-triggering: first clinical experience
Eur. Heart J., December 2, 2008; 29(24): 3037 - 3042.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
S. Zhang, D. C. Levin, E. J. Halpern, D. Fischman, M. Savage, and P. Walinsky
Accuracy of MDCT in Assessing the Degree of Stenosis Caused by Calcified Coronary Artery Plaques
Am. J. Roentgenol., December 1, 2008; 191(6): 1676 - 1683.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
P. Stolzmann, H. Scheffel, S. Leschka, A. Plass, S. Baumuller, B. Marincek, and H. Alkadhi
Influence of Calcifications on Diagnostic Accuracy of Coronary CT Angiography Using Prospective ECG Triggering
Am. J. Roentgenol., December 1, 2008; 191(6): 1684 - 1689.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
M. J. Budoff, D. Dowe, J. G. Jollis, M. Gitter, J. Sutherland, E. Halamert, M. Scherer, R. Bellinger, A. Martin, R. Benton, et al.
Diagnostic Performance of 64-Multidetector Row Coronary Computed Tomographic Angiography for Evaluation of Coronary Artery Stenosis in Individuals Without Known Coronary Artery Disease: Results From the Prospective Multicenter ACCURACY (Assessment by Coronary Computed Tomographic Angiography of Individuals Undergoing Invasive Coronary Angiography) Trial
J. Am. Coll. Cardiol., November 18, 2008; 52(21): 1724 - 1732.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
G Mowatt, J A Cook, G S Hillis, S Walker, C Fraser, X Jia, and N Waugh
64-Slice computed tomography angiography in the diagnosis and assessment of coronary artery disease: systematic review and meta-analysis
Heart, November 1, 2008; 94(11): 1386 - 1393.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
T. Maruyama, M. Takada, T. Hasuike, A. Yoshikawa, E. Namimatsu, and T. Yoshizumi
Radiation Dose Reduction and Coronary Assessability of Prospective Electrocardiogram-Gated Computed Tomography Coronary Angiography: Comparison With Retrospective Electrocardiogram-Gated Helical Scan
J. Am. Coll. Cardiol., October 28, 2008; 52(18): 1450 - 1455.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
P. Stolzmann, S. Leschka, H. Scheffel, T. Krauss, L. Desbiolles, A. Plass, M. Genoni, T. G. Flohr, S. Wildermuth, B. Marincek, et al.
Dual-Source CT in Step-and-Shoot Mode: Noninvasive Coronary Angiography with Low Radiation Dose
Radiology, October 1, 2008; 249(1): 71 - 80.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
S. Ghostine, C. Caussin, M. Habis, Y. Habib, C. Clement, A. Sigal-Cinqualbre, C.-Y. Angel, B. Lancelin, A. Capderou, and J.-F. Paul
Non-invasive diagnosis of ischaemic heart failure using 64-slice computed tomography
Eur. Heart J., September 1, 2008; 29(17): 2133 - 2140.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
A. C. Weustink, N. R. Mollet, F. Pugliese, W. B. Meijboom, K. Nieman, M. H. Heijenbrok-Kal, T. G. Flohr, L. A. E. Neefjes, F. Cademartiri, P. J. de Feyter, et al.
Optimal Electrocardiographic Pulsing Windows and Heart Rate: Effect on Image Quality and Radiation Exposure at Dual-Source Coronary CT Angiography
Radiology, September 1, 2008; 248(3): 792 - 798.
[Abstract] [Full Text] [PDF]


Home page
Circ Cardiovasc ImagingHome page
A.-C. Pouleur, J.-B. le Polain de Waroux, J. Kefer, A. Pasquet, J.-L. Vanoverschelde, and B. L. Gerber
Direct Comparison of Whole-Heart Navigator-Gated Magnetic Resonance Coronary Angiography and 40- and 64-Slice Multidetector Row Computed Tomography to Detect the Coronary Artery Stenosis in Patients Scheduled for Conventional Coronary Angiography
Circ Cardiovasc Imaging, September 1, 2008; 1(2): 114 - 121.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
S Leschka, H Scheffel, L Desbiolles, A Plass, O Gaemperli, P Stolzmann, M Genoni, T Luescher, B Marincek, P Kaufmann, et al.
Combining dual-source computed tomography coronary angiography and calcium scoring: added value for the assessment of coronary artery disease
Heart, September 1, 2008; 94(9): 1154 - 1161.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
H Scheffel, H Alkadhi, S Leschka, A Plass, L Desbiolles, I Guber, T Krauss, J Gruenenfelder, M Genoni, T F Luescher, et al.
Low-dose CT coronary angiography in the step-and-shoot mode: diagnostic performance
Heart, September 1, 2008; 94(9): 1132 - 1137.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
W. B. Meijboom, C. A.G. Van Mieghem, N. van Pelt, A. Weustink, F. Pugliese, N. R. Mollet, E. Boersma, E. Regar, R. J. van Geuns, P. J. de Jaegere, et al.
Comprehensive Assessment of Coronary Artery Stenoses: Computed Tomography Coronary Angiography Versus Conventional Coronary Angiography and Correlation With Fractional Flow Reserve in Patients With Stable Angina
J. Am. Coll. Cardiol., August 19, 2008; 52(8): 636 - 643.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. D. Dodd, J. Rieber, E. Pomerantsev, V. Chaithiraphan, S. Achenbach, J. M. Moreiras, S. Abbara, U. Hoffmann, T. J. Brady, and R. C. Cury
Quantification of Nonculprit Coronary Lesions: Comparison of Cardiac 64-MDCT and Invasive Coronary Angiography
Am. J. Roentgenol., August 1, 2008; 191(2): 432 - 438.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
G. Bastarrika, C. N. De Cecco, M. Arraiza, S. Mastrobuoni, J. C. Pueyo, M. Ubilla, and G. Rabago
Dual-Source CT for Visualization of the Coronary Arteries in Heart Transplant Patients with High Heart Rates
Am. J. Roentgenol., August 1, 2008; 191(2): 448 - 454.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
K. M. Takakuwa and E. J. Halpern
Evaluation of a "Triple Rule-Out" Coronary CT Angiography Protocol: Use of 64-Section CT in Low-to-Moderate Risk Emergency Department Patients Suspected of Having Acute Coronary Syndrome
Radiology, August 1, 2008; 248(2): 438 - 446.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
R. C. Cury, K. Nieman, M. D. Shapiro, J. Butler, C. H. Nomura, M. Ferencik, U. Hoffmann, S. Abbara, D. S. Jassal, T. Yasuda, et al.
Comprehensive Assessment of Myocardial Perfusion Defects, Regional Wall Motion, and Left Ventricular Function by Using 64-Section Multidetector CT
Radiology, August 1, 2008; 248(2): 466 - 475.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
O. Gaemperli, T. Schepis, I. Valenta, P. Koepfli, L. Husmann, H. Scheffel, S. Leschka, F. R. Eberli, T. F. Luscher, H. Alkadhi, et al.
Functionally Relevant Coronary Artery Disease: Comparison of 64-Section CT Angiography with Myocardial Perfusion SPECT
Radiology, August 1, 2008; 248(2): 414 - 423.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
D. A. Bluemke, S. Achenbach, M. Budoff, T. C. Gerber, B. Gersh, L. D. Hillis, W. G. Hundley, W. J. Manning, B. F. Printz, M. Stuber, et al.
Noninvasive Coronary Artery Imaging: Magnetic Resonance Angiography and Multidetector Computed Tomography Angiography: A Scientific Statement From the American Heart Association Committee on Cardiovascular Imaging and Intervention of the Council on Cardiovascular Radiology and Intervention, and the Councils on Clinical Cardiology and Cardiovascular Disease in the Young
Circulation, July 29, 2008; 118(5): 586 - 606.
[Full Text] [PDF]


Home page
BMJHome page
A. A Haydar, G. Morgan-Hughes, and C. Roobottom
Investigating severe interscapular pain
BMJ, July 21, 2008; 337(jul21_1): a688 - a688.
[Full Text]


Home page
J Am Coll Cardiol ImgHome page
V. Cheng, A. Gutstein, A. Wolak, Y. Suzuki, D. Dey, H. Gransar, L. E.J. Thomson, S. W. Hayes, J. D. Friedman, and D. S. Berman
Moving beyond binary grading of coronary arterial stenoses on coronary computed tomographic angiography insights for the imager and referring clinician.
J. Am. Coll. Cardiol. Img., July 1, 2008; 1(4): 460 - 471.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. L. Kelly, D. Thickman, S. D. Abramson, P. R. Chen, S. F. Smazal, M. J. Fleishman, and S. C. Lingam
Coronary CT Angiography Findings in Patients Without Coronary Calcification
Am. J. Roentgenol., July 1, 2008; 191(1): 50 - 55.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
I-C. Tsai, W.-L. Lee, C.-R. Tsao, Y. Chang, M.-C. Chen, T. Lee, and W.-C. Liao
Comprehensive Evaluation of Ischemic Heart Disease Using MDCT
Am. J. Roentgenol., July 1, 2008; 191(1): 64 - 72.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
W T Roberts, J J Bax, and L C Davies
Cardiac CT and CT coronary angiography: technology and application
Heart, June 1, 2008; 94(6): 781 - 792.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
F. Saremi, S. Channual, A. Abolhoda, S. V. Gurudevan, J. Narula, and J. C. Milliken
MDCT of the S-Shaped Sinoatrial Node Artery
Am. J. Roentgenol., June 1, 2008; 190(6): 1569 - 1575.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
S. Leschka, H. Scheffel, L. Husmann, O. Gamperli, B. Marincek, P. A. Kaufmann, and H. Alkadhi
Effect of Decrease in Heart Rate Variability on the Diagnostic Accuracy of 64-MDCT Coronary Angiography
Am. J. Roentgenol., June 1, 2008; 190(6): 1583 - 1590.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
H. Brodoefel, C. Burgstahler, I. Tsiflikas, A. Reimann, S. Schroeder, C. D. Claussen, M. Heuschmid, and A. F. Kopp
Dual-Source CT: Effect of Heart Rate, Heart Rate Variability, and Calcification on Image Quality and Diagnostic Accuracy
Radiology, May 1, 2008; 247(2): 346 - 355.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
H. S. Bedi, J. A. S. Gill, and S. S. Bakshi
Can we perform coronary artery bypass grafting on the basis of computed tomographic angiography alone? A comparison with conventional coronary angiography
Eur. J. Cardiothorac. Surg., April 1, 2008; 33(4): 633 - 638.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
K. Nieman, M. D. Shapiro, M. Ferencik, C. H. Nomura, S. Abbara, U. Hoffmann, H. K. Gold, I.-K. Jang, T. J. Brady, and R. C. Cury
Reperfused Myocardial Infarction: Contrast-enhanced 64-Section CT in Comparison to MR Imaging
Radiology, April 1, 2008; 247(1): 49 - 56.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
I. Gottlieb and J. A.C. Lima
Screening High-Risk Patients With Computed Tomography Angiography
Circulation, March 11, 2008; 117(10): 1318 - 1332.
[Full Text] [PDF]


Home page
CirculationHome page
C. M. Kramer
All High-Risk Patients Should Not Be Screened With Computed Tomographic Angiography
Circulation, March 11, 2008; 117(10): 1333 - 1339.
[Full Text] [PDF]


Home page
Eur Heart JHome page
V. Stangl, V. Witzel, G. Baumann, and K. Stangl
Current diagnostic concepts to detect coronary artery disease in women
Eur. Heart J., March 2, 2008; 29(6): 707 - 717.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
H. Alkadhi, H. Scheffel, L. Desbiolles, O. Gaemperli, P. Stolzmann, A. Plass, G. W. Goerres, T. F. Luescher, M. Genoni, B. Marincek, et al.
Dual-source computed tomography coronary angiography: influence of obesity, calcium load, and heart rate on diagnostic accuracy
Eur. Heart J., March 2, 2008; 29(6): 766 - 776.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
F. Cademartiri, E. Maffei, and N. R. Mollet
Is dual-source CT coronary angiography ready for the real world?
Eur. Heart J., March 2, 2008; 29(6): 701 - 703.
[Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
P. T. Johnson, J. Eng, H. K. Pannu, and E. K. Fishman
64-MDCT Angiography of the Coronary Arteries: Nationwide Survey of Patient Preparation Practice
Am. J. Roentgenol., March 1, 2008; 190(3): 743 - 747.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
A J H A Scholte, J D Schuijf, A V Kharagjitsingh, J W Jukema, G Pundziute, E E van der Wall, and J J Bax
Prevalence of coronary artery disease and plaque morphology assessed by multi-slice computed tomography coronary angiography and calcium scoring in asymptomatic patients with type 2 diabetes
Heart, March 1, 2008; 94(3): 290 - 295.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J. P. Earls, E. L. Berman, B. A. Urban, C. A. Curry, J. L. Lane, R. S. Jennings, C. C. McCulloch, J. Hsieh, and J. H. Londt
Prospectively Gated Transverse Coronary CT Angiography versus Retrospectively Gated Helical Technique: Improved Image Quality and Reduced Radiation Dose
Radiology, March 1, 2008; 246(3): 742 - 753.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. Leschka, P. Koepfli, L. Husmann, A. Plass, R. Vachenauer, O. Gaemperli, T. Schepis, M. Genoni, B. Marincek, F. R. Eberli, et al.
Myocardial Bridging: Depiction Rate and Morphology at CT Coronary Angiography--Comparison with Conventional Coronary Angiography
Radiology, March 1, 2008; 246(3): 754 - 762.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
S. Schroeder, S. Achenbach, F. Bengel, C. Burgstahler, F. Cademartiri, P. de Feyter, R. George, P. Kaufmann, A. F. Kopp, J. Knuuti, et al.
Cardiac computed tomography: indications, applications, limitations, and training requirements: Report of a Writing Group deployed by the Working Group Nuclear Cardiology and Cardiac CT of the European Society of Cardiology and the European Council of Nuclear Cardiology
Eur. Heart J., February 2, 2008; 29(4): 531 - 556.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. Horiguchi, M. Kiguchi, C. Fujioka, Y. Shen, R. Arie, K. Sunasaka, and K. Ito
Radiation Dose, Image Quality, Stenosis Measurement, and CT Densitometry Using ECG-Triggered Coronary 64-MDCT Angiography: A Phantom Study
Am. J. Roentgenol., February 1, 2008; 190(2): 315 - 320.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
F. Pugliese, N. R. Mollet, M. G. M. Hunink, F. Cademartiri, K. Nieman, R. T. van Domburg, W. B. Meijboom, C. Van Mieghem, A. C. Weustink, M. L. Dijkshoorn, et al.
Diagnostic Performance of Coronary CT Angiography by Using Different Generations of Multisection Scanners: Single-Center Experience
Radiology, February 1, 2008; 246(2): 384 - 393.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
L. Husmann, I. Valenta, O. Gaemperli, O. Adda, V. Treyer, C. A. Wyss, P. Veit-Haibach, F. Tatsugami, G. K. von Schulthess, and P. A. Kaufmann
Feasibility of low-dose coronary CT angiography: first experience with prospective ECG-gating
Eur. Heart J., January 2, 2008; 29(2): 191 - 197.
[Abstract] [Full Text] [PDF]


Home page
Card Surg AdultHome page
F. J. Rybicki, T. Sheth, and F. Y. Chen
Cardiac Surgical Imaging
Card. Surg. Adult, January 1, 2008; 3(2008): 179 - 198.
[Full Text]


Home page
HeartHome page
G Pundziute, J D Schuijf, J W Jukema, J M van Werkhoven, E Boersma, A de Roos, E E van der Wall, and J J Bax
Gender influence on the diagnostic accuracy of 64-slice multislice computed tomography coronary angiography for detection of obstructive coronary artery disease
Heart, January 1, 2008; 94(1): 48 - 52.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
J. Hausleiter, T. Meyer, M. Hadamitzky, M. Zankl, P. Gerein, K. Dorrler, A. Kastrati, S. Martinoff, and A. Schomig
Non-invasive coronary computed tomographic angiography for patients with suspected coronary artery disease: the Coronary Angiography by Computed Tomography with the Use of a Submillimeter resolution (CACTUS) trial
Eur. Heart J., December 2, 2007; 28(24): 3034 - 3041.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
J. Abdulla, S. Z. Abildstrom, O. Gotzsche, E. Christensen, L. Kober, and C. Torp-Pedersen
64-multislice detector computed tomography coronary angiography as potential alternative to conventional coronary angiography: a systematic review and meta-analysis
Eur. Heart J., December 2, 2007; 28(24): 3042 - 3050.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
A. R. Simon, H. Baraki, J. Weidemann, W. Harringer, M. Galanski, and A. Haverich
High-resolution 64-slice helical-computer-assisted-tomographical-angiography as a diagnostic tool before CABG surgery: the dawn of a new era?
Eur. J. Cardiothorac. Surg., December 1, 2007; 32(6): 896 - 901.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
C. S. White and D. Kuo
Chest Pain in the Emergency Department: Role of Multidetector CT
Radiology, December 1, 2007; 245(3): 672 - 681.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
F. Saremi, A. Abolhoda, O. Ashikyan, J. C. Milliken, J. Narula, S. V. Gurudevan, K. Kaushal, and A. Raney
Arterial Supply to Sinuatrial and Atrioventricular Nodes: Imaging with Multidetector CT
Radiology, December 1, 2007; 246(1): 99 - 107.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. Hamon, R. Morello, J. W. Riddell, and M. Hamon
Coronary Arteries: Diagnostic Performance of 16- versus 64-Section Spiral CT Compared with Invasive Coronary Angiography Meta-Analysis
Radiology, December 1, 2007; 245(3): 720 - 731.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
H. Brodoefel, U. Kramer, A. Reimann, C. Burgstahler, S. Schroeder, A. Kopp, and M. Heuschmid
Dual-Source CT with Improved Temporal Resolution in Assessment of Left Ventricular Function: A Pilot Study
Am. J. Roentgenol., November 1, 2007; 189(5): 1064 - 1070.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
W. B Meijboom, N. R Mollet, C. A Van Mieghem, A. C Weustink, F. Pugliese, N. van Pelt, F. Cademartiri, E. Vourvouri, P. de Jaegere, G. P Krestin, et al.
64-Slice CT coronary angiography in patients with non-ST elevation acute coronary syndrome
Heart, November 1, 2007; 93(11): 1386 - 1392.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
L. Husmann, S. Leschka, L. Desbiolles, T. Schepis, O. Gaemperli, B. Seifert, P. Cattin, T. Frauenfelder, T. G. Flohr, B. Marincek, et al.
Coronary Artery Motion and Cardiac Phases: Dependency on Heart Rate Implications for CT Image Reconstruction
Radiology, November 1, 2007; 245(2): 567 - 576.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
W. B. Meijboom, C. A.G. van Mieghem, N. R. Mollet, F. Pugliese, A. C. Weustink, N. van Pelt, F. Cademartiri, K. Nieman, E. Boersma, P. de Jaegere, et al.
64-Slice Computed Tomography Coronary Angiography in Patients With High, Intermediate, or Low Pretest Probability of Significant Coronary Artery Disease
J. Am. Coll. Cardiol., October 9, 2007; 50(15): 1469 - 1475.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
M. Dewey, H.-P. Dubel, T. Schink, G. Baumann, and B. Hamm
Head-to-head comparison of multislice computed tomography and exercise electrocardiography for diagnosis of coronary artery disease
Eur. Heart J., October 2, 2007; 28(20): 2485 - 2490.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
A. W. Leber, T. Johnson, A. Becker, F. von Ziegler, J. Tittus, K. Nikolaou, M. Reiser, G. Steinbeck, C. R. Becker, and A. Knez
Diagnostic accuracy of dual-source multi-slice CT-coronary angiography in patients with an intermediate pretest likelihood for coronary artery disease
Eur. Heart J., October 1, 2007; 28(19): 2354 - 2360.
[Abstract] [Full Text] [PDF]


Home page
Clin Med ResHome page
G. T. Wilson, P. Gopalakrishnan, and T. Tak
Noninvasive Cardiac Imaging with Computed Tomography
Clin. Med. Res., October 1, 2007; 5(3): 165 - 171.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
H. Alkadhi, L. Desbiolles, L. Husmann, A. Plass, S. Leschka, H. Scheffel, R. Vachenauer, T. Schepis, O. Gaemperli, T. G. Flohr, et al.
Aortic Regurgitation: Assessment with 64-Section CT
Radiology, October 1, 2007; 245(1): 111 - 121.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
D. Matt, H. Scheffel, S. Leschka, T. G. Flohr, B. Marincek, P. A. Kaufmann, and H. Alkadhi
Dual-Source CT Coronary Angiography: Image Quality, Mean Heart Rate, and Heart Rate Variability
Am. J. Roentgenol., September 1, 2007; 189(3): 567 - 573.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
L. J. M. Kroft, A. de Roos, and J. Geleijns
Artifacts in ECG-Synchronized MDCT Coronary Angiography
Am. J. Roentgenol., September 1, 2007; 189(3): 581 - 591.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
A.-C. Pouleur, J.-B. le Polain de Waroux, A. Pasquet, J.-L. J. Vanoverschelde, and B. L. Gerber
Aortic Valve Area Assessment: Multidetector CT Compared with Cine MR Imaging and Transthoracic and Transesophageal Echocardiography
Radiology, September 1, 2007; 244(3): 745 - 754.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
A. C. Weustink, W. B. Meijboom, N. R. Mollet, M. Otsuka, F. Pugliese, C. van Mieghem, R. Malago, N. van Pelt, M. L. Dijkshoorn, F. Cademartiri, et al.
Reliable High-Speed Coronary Computed Tomography in Symptomatic Patients
J. Am. Coll. Cardiol., August 21, 2007; 50(8): 786 - 794.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.