European Heart Journal Advance Access published online on March 1, 2005
European Heart Journal, doi:10.1093/eurheartj/ehi172
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
1 Hôpital Cardiologique du Haut-Lévêque, and Université Victor Segalen Bordeaux 2, Bordeaux, France
* To whom correspondence should be addressed. Aims Catheter ablation of atrial fibrillation (AF) is centred on pulmonary vein (PV) ablation with or without additional atrial substrate modification. These procedures may be prolonged with significant fluoroscopy exposure. This study evaluates a new non-fluoroscopic navigation system during ablation of AF. Methods and results Seventy-two patients undergoing catheter ablation of symptomatic drug refractory AF were prospectively randomized to ablation with (n = 35; study group) or without (n = 37; control group) non-fluoroscopic navigation. PV isolation was performed in all patients. In patients with persistent or inducible sustained AF after PV isolation linear ablation was performed by joining the superior PVs. PV isolation was achieved in all patients; fluoroscopy (15.4 ± 3.4 vs. 21.3 ± 6.4 min; P < 0.001) and procedural (52 ± 12 vs. 61 ± 17 min; P = 0.02) durations were significantly reduced in the study group. Linear block was achieved in 37 of the 39 patients; with a significant reduction in fluoroscopy (5.6 ± 2.2 vs. 9.9 ± 4.8 min; P = 0.003) and procedural (14.7 ± 5.5 vs. 26.6 ± 16.9 min; P = 0.007) durations in the study group. After a follow-up of 6.9 ± 2.9 months (range 3-10), 26 (74%) patients in the non-fluoroscopic navigation group and 29 (78%) patients in the control group were arrhythmia-free after the first procedure. Conclusion This prospectively randomized study demonstrates significant reduction of fluoroscopy exposure and procedural duration using supplementary non-fluoroscopic imaging system for AF ablation.
Clinical research
Reduction of fluoroscopy exposure and procedure duration during ablation of atrial fibrillation using a novel anatomical navigation system
Prashanthan Sanders, E-mail: prash.sanders{at}heartrhythm.org
![]()
Abstract ![]()
CiteULike
Connotea
Del.icio.us What's this?
This article has been cited by other articles:
![]() |
J. D. Burkhardt and A. Natale New Technologies in Atrial Fibrillation Ablation Circulation, October 13, 2009; 120(15): 1533 - 1541. [Full Text] [PDF] |
||||
![]() |
T. Terasawa, E. M. Balk, M. Chung, A. C. Garlitski, A. A. Alsheikh-Ali, J. Lau, and S. Ip Systematic Review: Comparative Effectiveness of Radiofrequency Catheter Ablation for Atrial Fibrillation Ann Intern Med, August 4, 2009; 151(3): 191 - 202. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. D. Powell and D. L. Packer Does image integration improve atrial fibrillation ablation outcomes, or are other aspects of the ablation the key to success? Europace, August 1, 2009; 11(8): 973 - 974. [Full Text] [PDF] |
||||
![]() |
M. D. O'Neill, P. Jais, M. Hocini, F. Sacher, G. J. Klein, J. Clementy, and M. Haissaguerre Catheter Ablation for Atrial Fibrillation Circulation, September 25, 2007; 116(13): 1515 - 1523. [Full Text] [PDF] |
||||
![]() |
Y. Van Belle, P. Janse, M. J. Rivero-Ayerza, A. S. Thornton, E. R. Jessurun, D. Theuns, and L. Jordaens Pulmonary vein isolation using an occluding cryoballoon for circumferential ablation: feasibility, complications, and short-term outcome Eur. Heart J., September 2, 2007; 28(18): 2231 - 2237. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Ector, O. Dragusin, B. Adriaenssens, W. Huybrechts, R. Willems, H. Ector, and H. Heidbuchel Obesity Is a Major Determinant of Radiation Dose in Patients Undergoing Pulmonary Vein Isolation for Atrial Fibrillation J. Am. Coll. Cardiol., July 17, 2007; 50(3): 234 - 242. [Abstract] [Full Text] [PDF] |
||||
![]() |
X.-h. Wang, X. Liu, Y.-m. Sun, J.-n. Gu, H.-f. Shi, L. Zhou, and W. Hu Early identification and treatment of PV re-connections: role of observation time and impact on clinical results of atrial fibrillation ablation Europace, July 1, 2007; 9(7): 481 - 486. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Kesek, N. Wallenius, F. Ronn, N. Hoglund, and S. Jensen Reduction of fluoroscopy duration in radiofrequency ablation obtained by the use of a non-fluoroscopic catheter navigation system Europace, December 1, 2006; 8(12): 1027 - 1030. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. L. Estner, I. Deisenhofer, A. Luik, G. Ndrepepa, C. von Bary, B. Zrenner, and C. Schmitt Electrical isolation of pulmonary veins in patients with atrial fibrillation: reduction of fluoroscopy exposure and procedure duration by the use of a non-fluoroscopic navigation system (NavX(R)) Europace, August 1, 2006; 8(8): 583 - 587. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. J. Earley, R. Showkathali, M. Alzetani, P. M. Kistler, D. Gupta, D. J. Abrams, J. A. Horrocks, S. J. Harris, S. C. Sporton, and R. J. Schilling Radiofrequency ablation of arrhythmias guided by non-fluoroscopic catheter location: a prospective randomized trial Eur. Heart J., May 2, 2006; 27(10): 1223 - 1229. [Abstract] [Full Text] [PDF] |
||||




