Skip Navigation



European Heart Journal Advance Access published online on June 29, 2005

European Heart Journal, doi:10.1093/eurheartj/ehi391
This Article
Right arrow Full Text (Rapid PDF)
Right arrow Supplementary data
Right arrow All Versions of this Article:
26/21/2313    most recent
ehi391v1
Right arrow E-letters: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Jahnke, C.
Right arrow Articles by Nagel, E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Jahnke, C.
Right arrow Articles by Nagel, E.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

European Heart Journal © The European Society of Cardiology 2005; all rights reserved
Received December 21, 2004
Revised April 19, 2005
Accepted April 22, 2005

Clinical research

Rapid and complete coronary arterial tree visualization with magnetic resonance imaging: feasibility and diagnostic performance

Cosima Jahnke 1*, Ingo Paetsch 2, Kay Nehrke 3, Bernhard Schnackenburg 2, Rolf Gebker 2, Eckart Fleck 2, and Eike Nagel 2

1 Department of Internal Medicine/Cardiology, German Heart Institute, Augustenburger Platz 1, 13353 Berlin, Germany; Department of Internal Medicine/Cardiology, University of Freiburg, Freiburg, Germany
2 Department of Internal Medicine/Cardiology, German Heart Institute, Augustenburger Platz 1, 13353 Berlin, Germany
3 Philips Research Laboratories, Hamburg, Germany

* To whom correspondence should be addressed.
Cosima Jahnke, E-mail: jahnke{at}dhzb.de


   Abstract

Aims Current imaging of the coronary arteries with magnetic resonance coronary angiography (MRCA) is restricted to limited coverage of the coronary arterial tree and requires complex planning. We present and evaluate a rapid, single-scan MRCA approach with complete coverage of the coronary arterial tree.

Methods and results Fifty-five consecutive patients with suspected coronary artery disease underwent free-breathing, navigator-gated MRCA using a single three-dimensional volume with transversal slice orientation and nearly isotropic spatial resolution (1.2 x 1.2 x 1.4 mm3) with coverage of the whole heart [steady-state free precession (SSFP); TR/TE/flip angle: 5.3 ms/2.6 ms/90°; Philips Intera CV 1.5T]. The acquisition duration per heart beat was individually adapted to the cardiac rest period. Correction of respiratory motion was done using a patient-specific affine prospective navigator technique (two navigator beams: cranio-caudal position on the dome of the right hemidiaphragm and anterior-posterior position on the right chest wall; gating window 10 mm). The diagnostic performance of MRCA in detecting significant coronary stenoses was evaluated against X-ray angiography as the standard of reference (32 patients) using a 16-segment model. Effective scan duration was 18 ± 6 min (navigator efficiency: 68 ± 14%). In all examinations, the main epicardial vessels [left anterior descending artery (LAD), left circumflex artery (LCX), and right coronary artery (RCA)], including their distal segments and major side branches (number of visible side branches: LAD, 2.0 ± 0.9; LCX, 1.5 ± 0.6; RCA, 2.3 ± 0.9), were reliably visualized. Eighty-three per cent of all coronary segments were evaluable; sensitivity, specificity, and diagnostic accuracy were 78, 91, and 89%, respectively.

Conclusion The combination of an imaging sequence with an intrinsically high contrast (SSFP) and a sophisticated navigator technique (affine transformation) resulted in high quality, high resolution imaging of the whole coronary arterial tree within a short examination duration. Robustness and diagnostic accuracy may allow for a routine application in the near future.

Keywords: Magnetic resonance imaging; Magnetic resonance coronary angiography; Coronary artery disease; Whole heart imaging.
Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
J Am Coll CardiolHome page
C. T. Sibley and D. A. Bluemke
Will 3.0-T make coronary magnetic resonance angiography competitive with computed tomography angiography?
J. Am. Coll. Cardiol., June 30, 2009; 54(1): 77 - 78.
[Full Text] [PDF]


Home page
RadiologyHome page
A. D. Scott, J. Keegan, and D. N. Firmin
Motion in Cardiovascular MR Imaging
Radiology, February 1, 2009; 250(2): 331 - 351.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll Cardiol ImgHome page
A. Chiribiri, S. Kelle, U. Kohler, L. F. Tops, B. Schnackenburg, R. Bonamini, J. J. Bax, E. Fleck, and E. Nagel
Magnetic resonance cardiac vein imaging: relation to mitral valve annulus and left circumflex coronary artery.
J. Am. Coll. Cardiol. Img., November 1, 2008; 1(6): 729 - 738.
[Abstract] [Full Text] [PDF]


Home page
Circ Cardiovasc ImagingHome page
P. J. de Feyter and R.-J. van Geuns
Noninvasive Coronary Imaging: The Contest Between Magnetic Resonance and Computed Tomographic Coronary Angiography
Circ Cardiovasc Imaging, September 1, 2008; 1(2): 89 - 91.
[Full Text] [PDF]


Home page
Circ Cardiovasc ImagingHome page
A.-C. Pouleur, J.-B. le Polain de Waroux, J. Kefer, A. Pasquet, J.-L. Vanoverschelde, and B. L. Gerber
Direct Comparison of Whole-Heart Navigator-Gated Magnetic Resonance Coronary Angiography and 40- and 64-Slice Multidetector Row Computed Tomography to Detect the Coronary Artery Stenosis in Patients Scheduled for Conventional Coronary Angiography
Circ Cardiovasc Imaging, September 1, 2008; 1(2): 114 - 121.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
D. A. Bluemke, S. Achenbach, M. Budoff, T. C. Gerber, B. Gersh, L. D. Hillis, W. G. Hundley, W. J. Manning, B. F. Printz, M. Stuber, et al.
Noninvasive Coronary Artery Imaging: Magnetic Resonance Angiography and Multidetector Computed Tomography Angiography: A Scientific Statement From the American Heart Association Committee on Cardiovascular Imaging and Intervention of the Council on Cardiovascular Radiology and Intervention, and the Councils on Clinical Cardiology and Cardiovascular Disease in the Young
Circulation, July 29, 2008; 118(5): 586 - 606.
[Full Text] [PDF]


Home page
RadiologyHome page
A. M. Gharib, V. B. Ho, D. R. Rosing, D. A. Herzka, M. Stuber, A. E. Arai, and R. I. Pettigrew
Coronary Artery Anomalies and Variants: Technical Feasibility of Assessment with Coronary MR Angiography at 3 T
Radiology, April 1, 2008; 247(1): 220 - 227.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
C. Burgstahler and S. Schroeder
Magnetic resonance imaging versus computed tomography for the detection of coronary stenosis: do we really have to focus on "stenoses"?
Heart, November 1, 2007; 93(11): 1322 - 1324.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
A H Gershlick, M de Belder, J Chambers, D Hackett, R Keal, A Kelion, S Neubauer, D J Pennell, M Rothman, M Signy, et al.
Role of non-invasive imaging in the management of coronary artery disease: an assessment of likely change over the next 10 years. A report from the British Cardiovascular Society Working Group
Heart, April 1, 2007; 93(4): 423 - 431.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
H. Sakuma, Y. Ichikawa, S. Chino, T. Hirano, K. Makino, and K. Takeda
Detection of Coronary Artery Stenosis With Whole-Heart Coronary Magnetic Resonance Angiography
J. Am. Coll. Cardiol., November 21, 2006; 48(10): 1946 - 1950.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.