Skip Navigation



European Heart Journal Advance Access published online on February 1, 2006

European Heart Journal, doi:10.1093/eurheartj/ehi755
This Article
Right arrow Full Text (Rapid PDF)
Right arrow All Versions of this Article:
27/10/1139    most recent
ehi755v1
Right arrow E-letters: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Limbruno, U.
Right arrow Articles by De Caterina, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Limbruno, U.
Right arrow Articles by De Caterina, R.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

European Heart Journal © The European Society of Cardiology 2006; all rights reserved
Received October 20, 2005
Revised December 11, 2005
Accepted January 13, 2006

Review

EMERALD, AIMI, and PROMISE: is there still a potential for embolic protection in primary PCI?

Ugo Limbruno 1 and Raffaele De Caterina 2 *

1 Cardiology Unit, Cardiovascular Department, ASL 6, Livorno, Italy
2 Department of Cardiology, Center of Excellence on Aging, ‘G. d'Annunzio’ University of Chieti, C/o Ospedale S. Camillo de Lellis Via Forlanini, 50 66100 Chieti, Italy; CNR Institute of Clinical Physiology, Pisa, Italy

* To whom correspondence should be addressed.
Raffaele De Caterina, E-mail: rdecater{at}unich.it


   Abstract

The recent trials of routine use of embolic protection devices for primary percutaneous coronary interventions (PCI) (the EMERALD, PROMISE, and AIMI trials) have demonstrated neutral or even negative effects of these devices on myocardial reperfusion and final infarct size. Despite these results, there is still ground to believe that PCI-induced embolization may be clinically relevant in specific subsets of patients with acute myocardial infarction (AMI). Significant clinical consequences may be expected when embolization is quantitatively relevant and/or is qualitatively characterized by lipid-rich athero-embolism (as is the case of lipid core embolization through the ruptured cap of a fibro-atheroma). Future trials on embolic protection devices in primary PCI should adopt a selective, rather than a routine strategy, through the identification, by angiographic or intravascular imaging parameters, of patients at highest risk of clinically relevant embolization. Such trials should also adopt specific endpoints able to evaluate the effect of micro-embolization, which is currently far from optimally assessed by the standard markers of myocardial reperfusion.

Keywords: Myocardial infarction; Percutaneous coronary interventions; Angioplasty; Embolization; Reperfusion.
Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Circ Cardiovasc IntervHome page
S. Kimura, T. Kakuta, T. Yonetsu, A. Suzuki, Y. Iesaka, H. Fujiwara, and M. Isobe
Clinical Significance of Echo Signal Attenuation on Intravascular Ultrasound in Patients With Coronary Artery Disease
Circ Cardiovasc Interv, October 1, 2009; 2(5): 444 - 454.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
L. Mauri, C. Rogers, and D. S. Baim
Devices for Distal Protection During Percutaneous Coronary Revascularization
Circulation, June 6, 2006; 113(22): 2651 - 2656.
[Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.