Skip Navigation



European Heart Journal Advance Access published online on April 13, 2006

European Heart Journal, doi:10.1093/eurheartj/ehi834
This Article
Right arrow Full Text (Rapid PDF)
Right arrow All Versions of this Article:
27/10/1223    most recent
ehi834v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Earley, M. J.
Right arrow Articles by Schilling, R. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Earley, M. J.
Right arrow Articles by Schilling, R. J.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

European Heart Journal © The European Society of Cardiology 2006; all rights reserved
Received November 7, 2005
Revised February 19, 2006
Accepted February 23, 2006

Clinical research

Radiofrequency ablation of arrhythmias guided by non-fluoroscopic catheter location: a prospective randomized trial

Mark J. Earley 1, Refai Showkathali 1, Maysaa Alzetani 1, Peter M. Kistler 1, Dhiraj Gupta 1, Dominic J. Abrams 1, Julie A. Horrocks 1, Stuart J. Harris 1, Simon C. Sporton 1, and Richard J. Schilling 1 *

1 Cardiology Research Department, Queen Mary University of London and St Bartholomew's Hospital, Dominion House, West Smithfield, London EC1A 7BE, UK

* To whom correspondence should be addressed.
Richard J. Schilling, E-mail: r.schilling{at}qmul.ac.uk


   Abstract

Aims To compare the utility of non-fluoroscopic mapping systems (Carto and Ensite NavX) with that of conventional mapping in patients referred for catheter ablation of a wide variety of arrhythmias.

Methods and results Patients referred for catheter ablation (excluding atrial fibrillation, atypical atrial flutter, ventricular tachycardia in structural heart disease, and complete AV nodal ablation) were randomized equally to a procedure guided by Carto, Ensite NavX, or conventional mapping. A total of 145 patients were recruited (82 men, aged 49 ± 16, range 18-85). In 19 patients, no ablation was performed, and in the remaining, typical atrial flutter, atrioventricular nodal re-entrant tachycardia, and atrioventricular re-entrant tachycardias [including Wolff-Parkinson-White (WPW)] accounted for 93% of ablations. Overall procedure time, immediate and short-term success, complication rate, and freedom from symptoms at follow-up were identical for all groups. NavX led to the least X-ray exposure: Navx vs. conventional, median (range): 4 (0-50) vs. 13 (2-46) min (P<0.001); NavX vs. Carto, median (range): 4 (0-50) vs. 6 (1-55) min (P=0.008). Both Carto and NavX increased disposable costs by 50% when compared with conventional (P<0.001). For typical atrial flutter, Carto and NavX reduced screening times without increasing procedure cost. If ablation was not performed, NavX was twice as expensive as Carto or conventional.

Conclusion Ensite NavX and Carto procedures have similar effectiveness and safety to a conventional approach; however, they both reduce X-ray exposure, with NavX producing a significantly greater effect than Carto. Although this benefit is achieved at a greater financial cost, there may be long-term benefits to catheter laboratory staff.

Keywords: Arrhythmia; Catheter ablation; Non-fluoroscopic; Mapping.
Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
EuropaceHome page
R. Showkathali, M. J. Earley, D. Gupta, M. Alzetani, S. Harris, P. M. Kistler, S. C. Sporton, and R. J. Schilling
Current case mix and results of catheter ablation of regular supraventricular tachycardia: are we giving unrealistic expectations to patients?
Europace, November 1, 2007; 9(11): 1064 - 1068.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
R. De Ponti and J. A. Salerno-Uriarte
Non-fluoroscopic mapping systems for electrophysiology: the 'tool or toy' dilemma after 10 years
Eur. Heart J., May 2, 2006; 27(10): 1134 - 1136.
[Full Text] [PDF]



Disclaimer:
Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.